U.S. Department of Health and Human Services

Class 2 Device Recall Brilliance CT 64, Ingenuity Core, and Ingenuity Core128 scanner

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC | Inspections
 


New Search Back to Search Results
 Class 2 Recall
Brilliance CT 64, Ingenuity Core, and Ingenuity Core128 scanner
see related information
Date Posted July 02, 2013
Recall Status1 Terminated on January 12, 2015
Recall Number Z-1646-2013
Recall Event ID 65139
Premarket Notification
510(K) Number
K033326 
Product Classification System, X-Ray, Tomography, Computed - Product Code JAK
Product Computed Tomography X-ray systems Product Usage: The Brilliance CT 64, Ingenuity Core, and Ingenuity Core128 scanners are whole body Computed Tomography X-ray systems that are intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes. This device may include signal analysis and display equipment, patient, and equipment supports, components and accessories.
Code Information The following system code numbers and associated serial numbers are affected by this recall: System Code #728231, Serial #: 4001, 4003, 4016, 4020, 9009, 9029, 9030, 9033, 9034, 9037, 9038, 9040, 9041, 9043, 9044, 9045, 9048, 9049, 9051, 9052, 9054, 9056, 9058, 9059, 9062, 9063, 9064, 9065, 9066, 9067, 9068, 9069, 9070, 9071, 9072, 9073, 9074, 9075, 9077, 9080, 9081, 9083, 9086, 9087, 9088, 9089, 9092, 9093, 9094, 9096, 9098, 9099, 9104, 9105, 9106, 9107, 9108, 9112, 9118, 9120, 9126, 9127, 9131, 9135, 9137, 9138, 9140, 9142, 9143, 9148, 9151, 9156, 9159, 9160, 9162, 9163, 9166, 9171, 9172, 9173, 9175, 9177, 9180, 9187, 9190, 9195, 9196, 9197, 9201, 9202, 9205, 9206, 9208, 9213, 9214, 9215, 9216, 9217, 9218, 9235, 9243, 9259, 9501, 9502, 9503, 9504, 9505, 9506, 9507, 9508, 9509, 9510, 9511, 9512, 9513, 9514, 9515, 9516, 9517, 9518, 9519, 9520, 9521, 9522, 9523, 9524, 9525, 9526, 9527, 9528, 9529, 9530, 9531, 9532, 9533, 9534, 9535, 9536, 9537, 9538, 9539, 9540, 9541, 9542, 9543, 9545, 9546, 9547, 9548, 9549, 9550, 9551, 9552, 9553, 9554, 9555, 9556, 9557, 9558, 9559, 9560, 9561, 9562, 9563, 9564, 9565, 9566, 9567, 9568, 9569, 9570, 9571, 9572, 9573, 9574, 9575, 9576, 9577, 9578, 9579, 9580, 9581, 9582, 9583, 9584, 9585, 9586, 9587, 9588, 9589, 9590, 9591, 9592, 9593, 9594, 9596, 9597, 9598, 9599, 9600, 9601, 9602, 9603, 9604, 9605, 9606, 9607, 9608, 9610, 9611, 9612, 9613, 9614, 9615, 9616, 9617, 9618, 9619, 9620, 9621, 9622, 9623, 9624, 9625, 9626, 9627, 9628, 9629, 9630, 9631, 9632, 9633, 9634, 9635, 9636, 9637, 9638, 9639, 9640, 9641, 9642, 9643, 9644, 9645, 9646, 9647, 9648, 9649, 9650, 9651, 9652, 9653, 9654, 9655, 9656, 9657, 9658, 9659, 9660, 9661, 9662, 9663, 9664, 9665, 9666, 9667, 9668, 9670, 9671, 9672, 9673, 9674, 9675, 9676, 9677, 9678, 9679, 9680, 9681, 9682, 9683, 9684, 9685, 9686, 9687, 9688, 9689, 9690, 9691, 9692, 9693, 9694, 9695, 9697, 9698, 9699, 9700, 9701, 9702, 9703, 9704, 9705, 9706, 9707, 9708, 9709, 9710, 9711, 9712, 9713, 9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721, 9722, 9723, 9724, 9725, 9726, 9727, 9728, 9729, 9730, 9731, 9732, 9734, 9735, 9736, 9737, 9738, 9739, 9740, 9741, 9742, 9743, 9744, 9745, 9746, 9747, 9748, 9749, 9750, 9751, 9752, 9753, 9754, 9755, 9756, 9757, 9758, 9759, 9760, 9761, 9762, 9763, 9764, 9765, 9766, 9767, 9768, 9769, 9770, 9771, 9772, 9773, 9774, 9775, 9776, 9777, 9778, 9779, 9780, 9781, 9782, 9783, 9784, 9785, 9786, 9787, 9788, 9789, 9790, 9791, 9792, 9793, 9794, 9795, 9796, 9797, 9798, 9799, 9800, 9801, 9802, 9803, 9804, 9805, 9806, 9807, 9808, 9809, 9810, 9811, 9812, 9813, 9814, 9815, 9816, 9817, 9818, 9819, 9820, 9821, 9822, 9823, 9824, 9825, 9826, 9827, 9829, 9830, 9831, 9832, 9833, 9834, 9835, 9836, 9837, 9838, 9839, 9840, 9841, 9842, 9843, 9844, 9845, 9846, 9847, 9848, 9849, 9850, 9852, 9853, 9854, 9855, 9856, 9857, 9858, 9859, 9860, 9861, 9862, 9863, 9864, 9865, 9866, 9867, 9868, 9869, 9870, 9871, 9872, 9873, 9874, 9875, 9876, 9877, 9878, 9879, 9880, 9881, 9882, 9883, 9884, 9885, 9886, 9887, 9888, 9889, 9890, 9891, 9892, 9893, 9894, 9895, 9896, 9898, 9899, 9900, 9901, 9902, 9903, 9904, 9905, 9906, 9907, 9908, 9909, 9910, 9911, 9912, 9913, 9914, 9915, 9916, 9917, 9918, 9919, 9920, 9921, 9922, 9923, 9924, 9925, 9926, 9927, 9929, 9930, 9931, 9933, 9936, 9937, 9938, 9940, 9941, 9942, 9946, 9947, 9948, 9950, 9951, 9952, 9953, 9954, 9956, 9957, 9958, 9959, 9960, 9961, 9963, 9964, 9965, 9966, 9968, 9969, 9970, 9971, 9972, 9974, 9975, 9976, 9978, 9980, 9981, 9982, 9983, 9984, 9985, 9986, 9987, 9989, 9991, 9993, 9994, 9995, 9996, 9997, 9998, 9999, 10000, 10001, 10002, 10003, 10004, 10005, 10006, 10007, 10008, 10009, 10011, 10012, 10014, 10015, 10016, 10017, 10018, 10019, 10020, 10021, 10022, 10023, 10024, 10025, 10026, 10027, 10028, 10030, 10031, 10032, 10033, 10034, 10035, 10036, 10037, 10039, 10040, 10041, 10042, 10044, 10045, 10046, 10047, 10048, 10049, 10050, 10051, 10052, 10053, 10054, 10056, 10057, 10058, 10059, 10060, 10061, 10064, 10065, 10066, 10067, 10068, 10069, 10070, 10071, 10072, 10073, 10075, 10077, 10078, 10079, 10080, 10081, 10083, 10084, 10085, 10086, 10087, 10088, 10089, 10090, 10092, 10094, 10095, 10096, 10097, 10098, 10099, 10100, 10101, 10102, 10103, 10104, 10105, 10106, 10107, 10108, 10109, 10110, 10111, 10112, 10113, 10114, 10115, 10116, 10117, 10118, 10119, 10120, 10121, 10122, 10123, 10124, 10125, 10126, 10127, 10128, 10129, 10130, 10131, 10132, 10134, 10135, 10136, 10137, 10138, 10139, 10140, 10141, 10142, 10143, 10144, 10145, 10146, 10147, 10148, 10149, 10150, 10151, 10152, 10153, 10154, 10155, 10156, 10157, 10158, 10160, 10161, 10162, 10164, 10165, 10166, 10167, 10168, 10169, 10170, 10171, 10172, 10174, 10176, 10177, 10178, 10179, 10180, 10181, 10183, 10184, 10185, 10186, 10187, 10188, 10190, 10191, 10192, 10193, 10194, 10195, 10196, 10197, 10198, 10200, 10201, 10202, 10203, 10204, 10205, 10206, 10207, 10208, 10209, 10210, 10211, 10212, 10213, 10214, 10215, 10216, 10217, 10218, 10219, 10220, 10221, 10222, 10223, 10224, 10225, 10226, 10227, 10228, 10229, 10230, 10231, 10234, 10235, 10237, 10238, 10239, 10240, 10241, 10242, 10243, 10244, 10245, 10246, 10247, 10248, 10250, 10251, 10252, 10253, 10254, 10255, 10256, 10257, 10258, 10259, 10260, 10261, 10262, 10263, 10264, 10265, 10266, 10267, 10268, 10269, 10270, 10271, 10272, 10273, 10274, 10275, 10276, 10277, 10278, 10279, 10280, 10281, 10282, 10283, 10284, 10285, 10286, 10287, 10288, 10291, 10292, 10293, 10294, 10295, 10296, 10297, 10298, 10299, 10300, 10301, 10302, 10303, 10304, 10305, 10307, 10308, 10309, 10310, 10311, 10312, 10313, 10314, 10315, 10316, 10317, 10318, 10319, 10320, 10321, 10322, 10323, 10324, 10325, 10327, 10330, 10331, 10332, 10333, 10334, 10335, 10336, 10337, 10338, 10339, 10341, 10342, 10343, 10344, 10345, 10346, 10347, 10348, 10349, 10350, 10351, 10352, 10353, 10354, 10355, 10357, 10358, 10359, 10360, 10361, 10362, 10363, 10364, 10365, 10366, 10367, 10368, 10369, 10370, 10371, 10372, 10373, 10374, 10375, 10376, 10378, 10379, 10380, 10381, 10383, 10384, 10385, 10386, 10388, 10389, 10390, 10391, 10392, 10393, 10394, 10395, 10396, 10397, 10398, 10399, 10400, 10401, 10402, 10403, 10404, 10405, 10406, 10407, 10408, 10409, 10410, 10411, 10412, 10413, 10414, 10415, 10416, 10417, 10418, 10419, 10420, 10421, 10422, 10424, 10425, 10426, 10427, 10428, 10429, 10430, 10431, 10432, 10434, 10435, 10436, 10437, 10438, 10439, 10440, 10441, 10442, 10443, 10444, 10445, 10446, 10447, 10448, 10449, 10450, 10451, 10452, 10453, 10454, 10455, 10456, 10457, 10458, 10459, 10460, 10461, 10462, 10463, 10464, 10465, 10466, 10467, 10468, 10469, 10470, 10471, 10472, 10473, 10474, 10475, 10476, 10477, 10478, 10479, 10480, 10481, 10482, 10483, 10484, 10485, 10486, 10487, 10488, 10489, 10490, 10491, 10492, 10494, 10495, 10496, 10497, 10498, 10499, 10500, 10502, 10503, 10504, 10505, 10506, 10507, 10508, 10510, 10511, 10512, 10513, 10514, 10515, 10516, 10517, 10518, 10519, 10520, 10521, 10522, 10523, 10525, 10526, 10527, 10528, 10530, 10531, 10532, 10533, 10534, 10535, 10536, 10537, 10538, 10539, 10540, 10541, 10542, 10543, 10545, 10546, 10547, 10548, 10549, 10550, 10551, 10552, 10553, 10554, 10555, 10556, 10557, 10558, 10559, 10560, 10561, 10562, 10563, 10564, 10565, 10566, 10567, 10568, 10569, 10570, 10571, 10572, 10573, 10574, 10575, 10576, 10577, 10578, 10579, 10580, 10581, 10582, 10583, 10584, 10585, 10586, 10587, 10588, 10589, 10590, 10591, 10592, 10593, 10594, 10595, 10596, 10597, 10598, 10599, 10600, 10601, 10602, 10603, 10604, 10605, 10606, 10607, 10608, 10609, 10610, 10611, 10612, 10613, 10614, 10615, 10616, 10617, 10618, 10619, 10621, 10622, 10623, 10624, 10625, 10626, 10627, 10628, 10629, 10630, 10631, 10632, 10633, 10634, 10635, 10636, 10637, 10638, 10639, 10640, 10641, 10642, 10643, 10644, 10645, 10646, 10647, 10648, 10649, 10650, 10651, 10652, 10653, 10654, 10655, 10656, 10657, 10658, 10659, 10660, 10661, 10662, 10663, 10664, 10665, 10666, 10667, 10668, 10669, 10670, 10671, 10672, 10673, 10674, 10675, 10676, 10677, 10678, 10679, 10680, 10681, 10682, 10683, 10684, 10685, 10686, 10687, 10688, 10689, 10690, 10691, 10692, 10693, 10694, 10695, 10696, 10697, 10698, 10699, 10700, 10701, 10702, 10703, 10704, 10705, 10706, 10707, 10708, 10710, 10712, 10713, 10714, 10715, 10717, 10718, 10720, 10721, 10722, 10723, 10724, 10725, 10726, 10727, 10728, 10730, 10731, 10733, 10734, 10735, 10736, 10737, 10738, 10739, 10740, 10741, 10742, 10743, 10744, 10745, 10747, 10748, 10749, 10750, 10751, 10752, 10753, 10755, 10756, 10757, 10758, 10759, 10760, 10761, 10762, 10763, 10764, 10765, 10766, 10767, 29002, 29003, 29005, 29007, 29014, 29016, 29018, 29022, 29024, 29025, 29026, 29027, 29034, 29035, 29037, 29038, 29044, 29045, 29049, 29054, 29056, 29057, 29062, 29070, 29086, 29092, 29097, 29107, 29111, 29113, 29124, 29138, 64015, 64040, 64051, 64117, 64135, 64151, 64152, 64153, 64158, 64163, 64167, 64168, 64173, 90029, 90030, 90031, 90033, 90036, 90037, 90041, 90042, 90045, 90046, 90047, 90050, 90057, 90058, 90060, 90062, 90063, 90066, 90070, 90072, 90073, 90077, 90078, 90079, 90080, 90081, 90082, 90084, 90086, 90087, 90089, 90091, 90092, 90094, 90096, 90097, 90098, 90099, 90100, 90102, 90105, 90106, 90107, 90117, 90118, 90120, 90123, 90124, 90129, 90131, 90132, 90136, 90137, 90139, 90140, 90141, 90143, 90147, 90150, 90151, 90152, 90153, 90154, 90156, 90157, 90159, 90160, 90161, 90162, 90163, 90167, 90168, 90169, 90175, 90177, 90180, 90182, 90185, 90187, 90205, 90208, 90213, 90218, 90221, 90223, 95003, 95008, 95009, 95011, 95012, 95013, 95014, 95015, 95016, 95017, 95018, 95019, 95020, 95021, 95022, 95023, 95024, 95025, 95029, 95030, 95031, 95032, 95033, 95034, 95035, 95036, 95037, 95038, 95039, 95040, 95041, 95042, 95043, 95044, 95045, 95047, 95048, 95049, 95050, 95051, 95052, 95053, 95054, 95055, 95056, 95057, 95059, 95060, 95061, 95062, 95063, 95064, 95065, 95066, 95067, 95068, 95069, 95071, 95072, 95073, 95074, 95075, 95076, 95077, 95078, 95079, 95080, 95081, 95082, 95083, 95084, 95085, 95086, 95087, 95088, 95089, 95090, 95091, 95092, 95093, 95094, 95095, 95096, 95097, 95098, 95099, 95100, 95101, 95102, 95103, 95104, 95105, 95106, 95107, 95108, 95109, 95110, 95111, 95112, 95113, 95114, 95116, 95117, 95118, 95119, 95120, 95121, 95122, 95123, 95124, 95125, 95126, 95127, 95128, 95129, 95130, 95131, 95132, 95133, 95134, 95135, 95136, 95137, 95138, 95139, 95140, 95141, 95142, 95143, 95144, 95145, 95146, 95147, 95149, 95150, 95151, 95152, 95153, 95154, 95155, 95156, 95157, 95158, 95159, 95161, 95162, 95163, 95164, 95165, 95167, 95168, 95169, 95170, 95171, 95172, 95173, 95175, 95176, 95177, 95178, 95179, 95180, 95182, 95183, 95184, 95185, 95186, 95187, 95188, 95189, 95190, 95191, 95192, 95193, 95194, 95195, 95196, 95197, 95198, 95199, 95200, 95201, 95202, 95203, 95204, 95205, 95206, 95207, 95208, 95210, 95212, 95213, 95214, 95215, 95216, 95217, 95218, 95219, 95220, 95221, 95222, 95223, 95224, 95225, 95226, 95227, 95228, 95229, 95231, 95232, 95233, 95234, 95235, 95236, 95237, 95238, 95239, 95240, 95241, 95242, 95243, 95244, 95245, 95246, 95247, 95249, 95250, 95251, 95252, 95253, 95254, 95255, 95256, 95257, 95258, 95259, 95260, 95261, 95262, 95263, 95264, 95265, 95266, 95267, 95268, 95269, 95270, 95271, 95272, 95273, 95274, 95275, 95276, 95277, 95278, 95279, 95280, 95281, 95282, 95283, 95284, 95285, 95286, 95287, 95288, 95289, 95290, 95291, 95292, 95293, 95294, 95296, 95297, 95298, 95299, 95300, 95301, 95302, 95303, 95304, 95305, 95308, 95309, 95310, 95311, 95312, 95313, 95314, 95315, 95316, 95317, 95318, 95319, 95320, 95321, 95322, 95323, 95324, 95325, 95326, 95327, 95328, 95329, 95330, 95331, 95332, 95333, 95334, 95335, 95336, 95337, 95338, 95339, 95340, 95342, 95343, 95344, 95345, 95346, 95347, 95348, 95349, 95350, 95351, 95352, 95353, 95354, 95355, 95356, 95357, 95358, 95359, 95360, 95361, 95362, 95363, 95364, 95365, 95366, 95369, 95370, 95371, 95374, 95375, 95376, 95377, 95378, 95379, 95380, 95381, 95382, 95383, 95385, 95386, 95387, 95388, 95389, 95390, 95391, 95393, 95394, 95395, 95396, 95397, 95398, 95399, 95400, 95401, 95402, 95403, 95404, 95405, 95406, 95407, 95408, 95409, 95410, 95411, 95412, 95413, 95414, 95415, 95416, 95417, 95418, 95419, 95420, 95421, 95422, 95424, 95425, 95426, 95427, 95428, 95429, 95430, 95431, 95432, 95433, 95434, 95435, 95436, 95437, 95438, 95439, 95440, 95441, 95442, 95443, 95444, 95445, 95446, 95447, 95448, 95449, 95450, 95451, 95452, 95453, 95454, 95455, 95456, 95457, 95458, 95459, 95461, 95462, 95463, 95464, 95465, 95466, 95467, 95468, 95469, 95470, 95471, 95472, 95473, 95474, 95475, 95476, 95477, 95479, 95480, 95481, 95482, 95483, 95484, 95485, 95486, 95487, 95488, 95489, 95490, 95491, 95492, 95493, 95494, 95495, 95496, 95497, 95498, 95499, 95500, 95501, 95502, 95503, 95504, 95505, 95506, 95507, 95508, 95509, 95510, 95511, 95512, 95513, 95514, 95515, 95516, 95517, 95518, 95519, 95520, 95521, 95522, 95523, 95524, 95525, 95526, 95527, 95528, 95529, 95530, 95531, 95532, 95533, 95534, 95535, 95536, 95537, 95538, 95540, 95541, 95542, 95543, 95544, 95545, 95546, 95547, 95548, 95549, 95550, 95551, 95552, 95554, 95555, 95556, 95557, 95558, 95559, 95560, 95561, 95563, 95564, 95565, 95566, 95567, 95568, 95569, 95570, 95571, 95572, 95573, 95574, 95575, 95577, 95578, 95579, 95580, 95581, 95582, 95583, 95584, 95585, 95586, 95587, 95588, 95589, 95590, 95591, 95592, 95595, 95596, 95597, 95598, 95599, 95600, 95601, 95602, 95603, 95604, 95605, 95606, 95607, 95608, 95609, 95610, 95611, 95612, 95613, 95614, 95615, 95616, 95617, 95618, 95620, 95621, 95622, 95623, 95624, 95625, 95626, 95627, 95628, 95629, 95630, 95631, 95632, 95633, 95634, 95635, 95636, 95637, 95638, 95639, 95640, 95641, 95642, 95643, 95644, 95645, 95646, 95647, 95648, 95649, 95650, 95651, 95652, 95653, 95654, 95655, 95656, 95657, 95658, 95659, 95660, 95661, 95662, 95664, 95665, 95666, 95667, 95668, 95669, 95670, 95671, 95672, 95673, 95674, 95675, 95676, 95677, 95678, 95679, 95680, 95681, 95682, 95683, 95684, 95685, 95686, 95687, 95688, 95689, 95690, 95691, 95692, 95693, 95694, 95695, 95696, 95697, 95698, 95699, 95700, 95702, 95703, 95704, 95705, 95706, 95707, 95708, 95709, 95710, 95711, 95712, 95713, 95714, 95715, 95716, 95718, 95719, 95720, 95721, 95722, 95723, 95724, 95725, 95726, 95727, 95729, 95730, 95731, 95732, 95733, 95734, 95735, 95736, 95737, 95738, 95739, 95740, 95741, 95742, 95743, 95744, 95745, 95746, 95747, 95748, 95749, 95750, 95751, 95752, 95753, 95754, 95755, 95756, 95757, 95758, 95759, 95760, 95761, 95764, 95765, 95767, 95768, 95769, 95770, 95772, 95773, 95774, 95775, 95776, 95777, 95778, 95779, 95780, 95781, 95782, 95783, 95784, 95785, 95786, 95787, 95788, 95789, 95790, 95791, 95792, 95793, 95794, 95795, 95796, 95797, 95798, 95799, 95800, 95801, 95802, 95803, 95804, 95805, 95806, 95807, 95808, 95809, 95810, 95811, 95812, 95814, 95815, 95816, 95817, 95818, 95819, 95820, 95821, 95822, 95823 System Code #728321, Serial #: 310001, 310002, 310003, 310004, 310005, 310006, 310007, 310010, 310011, 310012, 310013, 310014, 310015, 310016, 310017, 310018, 310019, 310020, 310021, 310022, 310023, 310024, 310025, 310026, 310027, 310028, 310029, 310030, 310031, 310032, 310033, 310034, 310035, 310036, 310037, 310038, 310040, 310041, 310043, 310044, 310045, 310046, 310047, 310048, 310049, 310050, 310051, 310052, 310053, 310054, 310055, 310056, 310057, 310058, 310059, 310060, 310061, 310062, 310063, 310065, 310066, 310067, 310068, 310069, 310071, 310072, 310073, 310074, 310075, 310076, 310077, 310078, 310079, 310080, 310082, 310083, 310084, 310085, 310086, 310087, 310088, 310089, 310090, 310091, 310092, 310093, 310094, 310095, 310096, 333001, 333007 System Code #728323, Serial #: 320002, 320003, 320004, 320005, 320006, 320007, 320008, 320009, 320010, 320011, 320013, 320014, 320015, 320017, 320018, 320019, 320020, 320022, 320023, 320024, 320025, 320026, 320027, 320028, 320029, 320031, 320032, 320034, 320035, 320036, 320037, 320038, 320039, 320040, 320041, 320043, 320044, 320045, 320046, 320047, 320048, 320049, 320050, 320051, 320052, 320053, 320054, 320055, 320056, 320057, 320059, 320060, 320062, 320063, 320064, 320065, 320066, 320067, 320068, 320069, 320070, 320071, 320072, 320074, 320075, 320078, 320079
Recalling Firm/
Manufacturer
Philips Medical Systems (Cleveland) Inc
595 Miner Rd
Cleveland, Ohio 44143-2131
Manufacturer Reason
for Recall
Philips Healthcare received reports from the field that certain Brilliance CT 64, Ingenuity Core, and Ingenuity Core128 systems running software versions 2.6.1 or 3.5.4 exhibited intermittent swirl-like ring artifacts that may appear on reconstructed images, which may impair the diagnostic quality of affected images.
FDA Determined
Cause 2
DESIGN: Software Design
Action Philips Healthcare sent an Urgent Medical device Correction letter dated April 15, 2013 to all affected customers. The letter identified the affected product, problem and actions to be taken. The letter states that Philips Healthcare is implementing software update versions 2.6.2 or 3.5.5 to resolve the issue and a Philips Field Service Engineer will contact each site to schedule the software installation. For questions contact your local Philips representative or local Philips Healthcare office.
Quantity in Commerce 2348 total units: 2182 Brilliance CT 64 units; 95 Ingenuity Core units; and 71 Ingenuity Core128 units.
Distribution USA Nationwide Distribution - including the states of: AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, NC, ND, NE, NJ, NM, NV, NY, OH, OK, OR, PA, PR, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY.
Total Product Life Cycle TPLC Device Report

 
1 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
510(K) Database 510(K)s with Product Code = JAK and Original Applicant = PHILIPS MEDICAL SYSTEMS, INC.
-
-