Date Initiated by Firm |
March 13, 2019 |
Create Date |
August 08, 2019 |
Recall Status1 |
Terminated 3 on March 05, 2024 |
Recall Number |
Z-2216-2019 |
Recall Event ID |
83324 |
510(K)Number |
K893439
|
Product Classification |
Catheter, subclavian - Product Code LFJ
|
Product |
14F x 24CM SLX Double Lumen Full Tray Hemodialysis catheter insertion kits, Item No. MC061424
Product Usage: An aid for introducing a hemodialysis catheter |
Code Information |
MCAL430 MCAT000 MCBM770 MCBS380 MCCC840 MCCM930 MCCS360 MCCZ450 MCDC580 MCDN120 MCDR420 MCFB350 MCFG980 MCFM410 MCFP230 MCFT430 MCFZ290 MKAF350 MKAG490 MKAM210 MKAR120 MKBA200 MKBL090 MKBL220 MKBV580 MMAB710 MMAM070 MMAQ950 |
Recalling Firm/ Manufacturer |
Medical Components, Inc dba MedComp 1499 Delp Dr Harleysville PA 19438-2936
|
For Additional Information Contact |
Customer service 215-256-4201
|
Manufacturer Reason for Recall |
Tray label indicates the kits are packaged with a 15F "valved" peelable introducer, but the kits contain a 15F "non-valved" peelable introducer.
|
FDA Determined Cause 2 |
Labeling Change Control |
Action |
On March 13, 2019, the firm notified customers via Urgent Medical Device Recall letter. Customers were
informed that the kits contain a 15F "non-valved" peelable introducer despite the label indicating that the kit is
packaged with a "valved" introducer. Customers were asked to do the following: 1. Immediately examine your
inventory and quarantine product subject to recall. 2. If you have further distributed this product, please
identify your customers and immediately notify them of the recall. 3. Contact your Medical Components, Inc.
customer service representative for a Returned Goods Authorization (RGA) number if you have product to
return. The phone number to call is 215-256-4201. 4.Complete and return the Medical Device Recall Return
Response Form. The form can be returned by fax (215-256-9191) or email (recalls@medcompnet.com).
Contact Information for questions: Monday through Friday, 8:00 AM to 4:00 PM, Eastern Standard Time.
Phone: 215-256-4201; Email: recalls@medcompnet.com |
Quantity in Commerce |
6830 |
Distribution |
US Nationwide Distribution CA FL GA IN KY LA MA MI MO MS NJ NY OH OK PA SC TN TX VA WV. |
Total Product Life Cycle |
TPLC Device Report
|
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
|
510(K) Database |
510(K)s with Product Code = LFJ and Original Applicant = MEDICAL COMPONENTS, INC.
|