• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Class 2 Device Recall GE Healthcare Advantage Workstations

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 


New Search Back to Search Results
  Class 2 Device Recall GE Healthcare Advantage Workstations see related information
Date Initiated by Firm September 10, 2007
Date Posted November 28, 2007
Recall Status1 Terminated 3 on December 17, 2011
Recall Number Z-0265-2008
Recall Event ID 45514
510(K)Number K020483  K052995  
Product Classification Image processing system - Product Code LLZ
Product GE Healthcare Advantage Workstations, Advantage Worksation version 4.2 and 4.3 with Volume Viewer 2 (version 6.4-6.8) provided with Advance Vessel Analysis (AVA) and Advantage Worksation 4.4 with Volume Viewer 2 (version 6.8 or before) or Volume Viewer 3 (version 7.2 -7.3) provided with Advanced Vessel Analysis (AVA), Model 2378698-2,GE Healthcare, Waukesha, WI. 53188
Code Information Model 2378698-2 Serial #: 00000048570GE6 00000026242GE8 00000021465GE0 00000057141GE4 00000080246GE2 00000082828GE5 00000021776GE0 00000022426GE1 00000017866GE5 00000015743GE8 00000009840GE0 00000056383GE3 00000060521GE2 00000080136GE5 00000054095GE5 00000020473AW5 00000066933GE3 00000056368GE4 00000061919GE7 00000068157GE7 00000009838GE4 00000049905GE3 00000063495GE6 00000070180GE5 00000061922GE1 00000061923GE9 00000022425GE3 00000023775GE0 00000018684GE1 00000014239GE8 00000016974GE8 00000020873GE6 00000028471GE1 00000056378GE3 00000014233GE1 00000020982GE5 00000009846GE7 00000033292AW4 00000024404GE6 00000025815GE2 00000020438AW8 00000014238GE0 00000059320GE2 00000055098GE8 00000019216GE1 00000029213GE6 00000069440GE6 00000069439GE8 00000022427GE9 00000066941GE6 00000486421BU1 00000027277AW3 00000027276AW5 00000052488AW4 00000062286GE0 00000072425GE2 00000020300GE0 00000020974GE2 00000012226GE7 00000012225GE9 00000011140GE1 00000011138GE5 00000011139GE3 00000011136GE9 00000015741GE2 00000017862GE4 00000019219GE5 00000022424GE6 00000052451GE2 00000087148GE3 00000020409AW9 00000059324GE4 00000078059GE3 00000078058GE5 00000081171GE1 00000070183GE9 00000069445GE5 00000030200GE0 00000027284AW9 00000036826AW6 00000020443AW8 00000030123AW4 00000070187GE0 00000024210AW7 00000020426AW3 00000020983GE3 00000023786GE7 00000014235GE6 00000022412GE1 00000058138GE9 00000030067AW3 00000030070AW7 00000030083AW0 00000023771GE9 00000058123GE1 00000023770GE1 00000058133GE0 00000066940GE8 00000058135GE5 00000069448GE9 00000058122GE3 00000023773GE5 00000058134GE8 00000081877GE3 00000068164GE3 00000019314GE4 00000024412GE9 00000024409GE5 00000061909GE8 00000078730GE9 00000026247GE7 00000029208GE6 00000030205GE9 00000042039GE8 00000052958GE6 00000059321GE0 00000016374GE1 00000024420GE2 00000076621GE2 00000076195GE7 00000080740GE4 00000080746GE1 00000061911GE4 00000078729GE1 00000040372GE5 00000048569GE8 00000076196GE5 00000027389GE6 00000037147GE6 00000020406AW5 00000047194GE6 00000057155GE4 00000047197GE9 00000018675GE9 00000049904GE6 00000049903GE8 00000019310GE2 00000065283GE4 00000010743GE3 00000010744GE1 00000047199GE5 00000020872GE8 00000047193GE8 00000025406GE0 00000027398GE7 00000026604GE9 00000026605GE6 00000027402GE7 00000018359AW0 00000057148GE9 00000070852GE9 00000009843GE4 00000042038GE0 00000044314GE3 00000047188GE8 00000045183GE1 00000037458GE7 00000059329GE3 00000010384GE6 00000017856GE6 00000044211GE1 00000054097GE1 00000051797GE9 00000039602GE8 00000039604GE4 00000035037GE1 00000063507GE8 00000075389GE7 00000055104GE4 00000078060GE1 00000035038GE9 00000046334GE9 00000054093GE0 00000034345GE9 00000025419GE3 00000065288GE3 00000061914GE8 00000035129GE6 00000049915GE2 00000086697GE0 00000060837GE2 00000047613GE5 00000018670GE0 00000029207GE8 00000046326GE5 00000047609GE3 00000033939GE0 00000021467GE6 00000051141GE0 00000044213GE7 00000045187GE2 00000047608GE5 00000014231GE5 00000014230GE7 00000014232GE3 00000087646GE6 00000055093GE9 00000055100GE2 00000069441GE4 00000025415GE1 00000051798GE7 00000033932GE5 00000046336GE4 00000025812GE9 00000042384GE8 00000033930GE9 00000052950GE3 00000002540GE1 00000025420GE1 00000056365GE0 00000078731GE7 00000078733GE3 00000078732GE5 00000026253GE5 00000018676GE7 00000063492GE3 00000078056GE9 00000020499AW0 00000034408GE5 00000047619GE2 00000049057GE3 00000049058GE1 00000059323GE6 00000018362AW4 00000059322GE8 00000060829GE9 00000034980GE3 00000010746GE6 00000054094GE8 00000020435AW4 00000013243GE1 00000028472GE9 00000072433GE6 00000028473GE7 00000050130GE4 00000044052GE9 00000044199GE8 00000080243GE9 00000012219GE2 00000045178GE1 00000034405GE1 00000024223AW0 00000046338GE0 00000076618GE8 00000017857GE4 00000019215GE3 00000019214GE6 00000018678GE3 00000029196GE3 00000019309GE4 00000048572GE2 00000011150GE0 00000060524GE6 00000010041GE2 00000011068GE4 00000043540GE4 00000049062GE3 00000033928GE3 00000033935GE8 00000057157GEO 00000074406GE0 00000024245AW3 00000009589GE3 00000075384GE8 00000025819GE4 00000039605GE1 00000047202GE7 00000034415GE0 00000025407GE8 00000080239GE7 00000051786GE2 00000012224GE2 00000011270GE6 00000065183GE6 00000028464GE6 00000081335GE2 00000044045GE3 00000034403GE6 00000020449AW5 00000011148GE4 00000053473GE5 00000046989GE0 00000046990GE8 00000063502GE9 00000025412GE8 00000029198GE9 00000019674GE1 00000086700GE2 00000031392GE4 00000046323GE2 00000047616GE8 00000024407GE9 00000062298GE5 00000082958GE0 00000060825GE7 00000060826GE5 00000065895GE5 00000040614GE0 00000060520GE4 00000059330GE1 00000059331GE9 00000010589GE0 00000009297GE3 00000072427GE8 00000016979GE7 00000056374GE2 00000052439GE7 00000080376GE7 00000075858GE1 00000078728GE3 00000057145GE5 00000042390GE5 00000010383GE8 00000025418GE5 00000062291GE0 00000021787GE7 00000056371GE8 00000014236GE4 00000068168GE4 00000020452AW9 00000021468GE4 00000088713GE3 00000088714GE1 00000020494AW1 00000031398GE1 00000035284GE9 00000047186GE2 00000051793GE8 00000082829GE3 00000069442GE2 00000040618GE1 00000065180GE2 00000044051GE1 00000049064GE9 00000057146GE3 00000057147GE1 00000078725GE9 00000044207GE9 00000044208GE7 00000019318GE5 00000075850GE8 00000056375GE9 00000065900GE3 00000044046GE1 00000053480GE0 00000076611GE3 00000024208AW1 00000016973GE0 00000035287GE2 00000028475GE2 00000012218GE4 00000080244GE7 00000019684GE0 00000026602GE3 00000026239GE4 00000033929GE1 00000034412GE7 00000047618GE4 00000020429AW7 00000027387GE0 00000060827GE3 00000060828GE1 00000027401GE9 00000046986GE6 00000056376GE7 00000024418GE6 00000072437GE7 00000055109GE3 00000018680GE9 00000071500GE3 00000036082GE6 00000047607GE7 00000020483AW4 00000026246GE9 00000009839GE2 00000078057GE7 00000018679GE1 00000015745GE3 00000086806GE7 00000086807GE5 00000086808GE3 00000076202GE1 00000053465GE1 00000015749GE5 00000036076GE8 00000074415GE1 00000070847GE9 00000070848GE7 00000036075GE0 00000058137GE1 00000488150BU4 00000075394GE7 00000010043GE8 00000043539GE6 00000045177GE3 00000019687GE3 00000023787GE5 00000046340GE6 00000039599GE6 00000071493GE1 00000071494GE9 00000064362GE7 00000021789GE3 00000033941GE6 00000042389GE7 00000080374GE2 00000038979GE1 00000055102GE8 00000028480GE2 00000052438GE9 00000040619GE9 00000047191GE2 00000022430GE3 00000020985GE8 00000020986GE6 00000020453AW7 00000012222GE6 00000010040GE4 00000052448GE8 00000052447GE0 00000064358GE5 00000070839GE6 00000070840GE4 00000065151GE0 00000076207GE0 00000017860GE8 00000025805GE3 00000025804GE6 00000025806GE1 00000066946GE5 00000018681GE7 00000081332GE9 00000050135GE3 00000034341GE8 00000033942GE4 00000076615GE4 00000065893GE0 00000075852GE4 00000057156GE2 00000070853GE7 00000027388GE8 00000038395GE0 00000033933GE3 00000075390GE5 00000045175GE7 00000044212GE9 00000026249GE3 00000081329GE5 00000072430GE2 00000060529GE5 00000057142GE2 00000057143GE0 00000037463GE7 00000037464GE5 00000068159GE3 00000068160GE1 00000068161GE9 00000068162GE7 00000025421GE9 00000041174GE4 00000017854GE1 00000061920GE5 00000075391GE3 00000075392GE1 00000021780GE2 00000021782GE8 00000020875GE1 00000065182GE8 00000038976GE7 00000043538GE8 00000025822GE8 00000041873GE1 00000044205GE3 00000021778GE6 00000021779GE4 00000046339GE8 00000080131GE6 00000066936GE6 00000016378GE2 00000044210GE3 00000027399GE5 00000009591GE9 00000028466GE1 00000074413GE6 00000027405GE0 00000`71496GE4 00000075387GE1 00000019212GE0 00000045182GE3 00000043549GE5 00000044043GE8 00000488142BU1 00000016381GE6 00000066938GE2 00000010263GE2 00000010264GE0 00000010381GE2 00000057159GE6 00000065184GE4 00000043838GE2 00000013238GE1 00000036073GE5 00000043536GE2 00000017859GE0 00000054107GE8 00000065892GE2 00000068165GE0 00000055094GE7 00000078053GE6 00000020422AW2 00000068151GE0 00000044309GE3 00000044310GE1 00000020424AW8 00000051139GE4 00000051142GE8 00000045188GE0 00000063506GE0 00000081331GE1 00000022420GE4 00000068153GE6 00000044315GE0 00000042388GE9 00000048563GE1 00000082390GE6 00000063491GE5 00000046342GE2 00000024413GE7 00000015747GE9 00000009593GE5 00000009588GE5 00000082959GE8 00000080241GE3 00000033934GE1 00000047322GE3 00000036078GE4 00000019312GE8 00000021464GE3 00000051796GE1 00000020979GE1 00000020980GE9 00000040620GE7 00000020880GE1 00000023784GE2 00000088723GE2 00000040368GE3 00000042036GE4 00000050131GE2 00000080371GE8 00000048576GE3 00000020981GE7 00000035034GE8 00000082954GE9 00000009835GE0 00000045192GE2 00000045191GE4 00000020975GE9 00000049902GE0 00000054108GE6 00000044044GE6 00000048567GE2 00000054109GE4 00000019671GE7 00000009290GE8 00000076607GE1 00000088711GE7 00000065896GE3 00000017864GE0 00000014229GE9 00000031390GE8 00000066944GE0 00000060832GE3 00000060835GE6 00000027386GE2 00000023768GE5 00000011147GE6 00000019220GE3 00000038389GE3 00000081846GE8 00000070185GE4 00000076610GE5 00000010265GE7 00000046983GE3 00000055095GE4 00000035286GE4 00000038972GE6 00000034413GE5 00000064359GE3 00000019669GE1 00000028470GE3 00000047319GE9 00000018674GE2 00000052951GE1 00000018682GE5 00000038974GE2 00000055092GE1 00000053464GE4 00000053463GE6 00000036074GE3 00000034344GE2 00000023783GE4 00000072435GE1 00000053478GE4 00000022421GE2 00000010739GE1 00000086698GE8 00000075395GE4 00000080139GE9 00000026252GE7 00000010588GE2 00000074408GE6 00000072429GE4 00000036081GE8 00000036083GE4 00000080747GE9 00000052942GE0 00000044206GE1 00000054096GE3 00000044317GE6 00000038977GE5 00000031397GE3 00000035285GE6 00000017865GE7 00000053479GE2 00000075380GE6 00000041825GE1 00000009845GE9 00000031386GE6 00000026245GE1 00000026237GE8 00000021463GE5 00000021777GE8 00000036084GE2 00000043542GE0 00000065284GE2 00000009836GE8 00000038394GE3 00000040611GE6 00000019683GE2 00000028483GE6 00000030198GE6 00000066934GE1 00000025405GE2 00000033940GE8 00000034407GE7 00000048571GE4 00000078065GE0 00000037151GE8 00000061906GE4 00000046991GE6 00000042383GE0 00000074407GE8 00000071487GE3 00000036072GE7 00000013246GE4 00000013247GE2 00000019672GE5 00000019681GE6 00000026244GE4 00000047196GE1 00000023776GE8 00000060523GE8 00000010038GE8 00000052443GE9 00000015742GE0 00000086688GE9 00000065286GE7 00000018683GE3 00000087649GE0 00000036071GE9 00000010585GE8 00000010586GE6 00000010382GE0 00000010587GE4 00000069449GE7 00000086812GE5 00000044204GE6 00000072424GE5 00000083773GE2 00000062290GE2 00000040364GE2 00000060526GE1 00000055110GE1 00000021785GE1 00000082835GE0 00000052954GE5 00000063493GE1 00000074403GE7 00000025814GE5 00000040615GE7 00000071491GE5 00000020441AW2 00000080140GE7 00000050138GE7 00000048568GE0 00000068158GE5 00000026603GE1 00000038391GE9 00000027396GE1 00000027397GE9 00000051799GE5 00000019673GE3 00000021788GE5 00000025414GE4 00000076603GE0 00000060525GE3 00000082965GE5 00000078721GE8 00000011151GE8 00000048562GE3 00000019315GE1 00000020423AW0 00000051143GE6 00000019306GE0 00000019305GE2 00000043537GE0 00000031401GE3 00000046335GE6 00000043547GE9 00000041177GE7 00000034410GE1 00000047320GE7 00000060823GE2 00000042385GE5 00000022423GE8 00000076194GE0 00000052441GE3 00000070844GE6 00000009842GE6 00000054101GE1 00000035282GE3 00000062292GE8 00000055103GE6 00000065897GE1 00000017867GE3 00000009294GE0 00000035039GE7 00000046333GE1 00000021781GE0 00000010262GE4 00000026608GE0 00000014227GE3 00000020978GE3 00000020296GE0 00000051037GE0 00000051039GE6 00000020297GE8 00000051032GE1 00000020770GE4 00000020767GE0 00000051035GE4 00000020295GE2 00000020769GE6 00000051030GE5 00000051031GE3 00000051033GE9 00000051034GE7 00000051036GE2 00000020298GE6 00000051038GE8 00000020768GE8 00000020766GE2 00000063499GE8 00000009837GE6 00000038388GE5 00000065186GE9 00000050133GE8 00000054106GE0 00000082966GE3 00000059313GE7 00000041175GE1 00000025818GE6 00000069438GE0 00000048573GE0 00000009295GE7 00000066945GE7 00000013241GE5 00000046984GE1 00000019213GE8 00000047203GE5 00000059318GE6 00000038981GE7 00000020436AW2 00000086689GE7 00000011070GE0 00000040366GE7 00000018350AW9 00000034981GE1 00000066932GE5 00000038973GE4 00000064364GE3 00000080375GE9 00000033937GE4 00000051136GE0 00000072434GE4 00000050132GE0 00000047328GE0 00000047605GE1 00000070843GE8 00000063494GE9 00000028481GE0 00000028482GE8 00000018673GE4 00000019688GE1 00000051790GE4 00000009834GE3 00000078722GE6 00000078723GE4 00000082830GE1 00000005244GE7 00000049059GE9 00000070198GE7 00000076612GE1 00000081334GE5 00000060527GE9 00000065179GE4 00000065178GE6 00000009296GE5 00000051802GE7 00000078055GE1 00000075386GE3 00000076198GE1 00000031396GE5 00000057140GE6 00000076201GE3 00000020428AW9 00000047185GE4 00000053477GE6 00000044202GE0 00000046327GE3 00000046328GE1 00000052944GE6 00000053468GE5 00000035283GE1 00000060822GE4 00000056370GE0 00000038975GE9 00000078054GE4 00000010261GE6 00000047604GE4 00000019221GE1 00000028479GE4 00000036079GE2 00000036070GE1 00000011069GE2 00000023774GE3 00000019311GE0 00000024408GE7 00000088033GE6 00000020462AW8 00000020463AW6 00000074414GE4 00000051800GE1 00000031395GE7 00000024242AW0 00000058124GE9 00000018671GE8 00000060833GE1 00000050137GE9 00000083769GE0 00000055106GE9 00000055107GE7 00000058129GE8 00000054103GE7 00000010035GE4 00000009833GE5 00000034414GE3 00000047602GE8 00000051138GE6 00000024207AW3 00000042386GE3 00000486414BU6 00000053467GE7 00000037149GE2 00000062295GE1 00000021783GE6 00000029200GE3 00000061915GE5 00000047603GE6 00000051791GE2 00000024411GE1 00000011264GE9 00000058125GE6 00000038390GE1 00000010521GE3 00000059328GE5 00000063500GE3 00000059327GE7 00000062293GE6 00000052948GE7 00000052949GE5 00000085200GE4 00000085201GE2 00000085202GE0 00000066948GE1 00000087336GE0 00000047606GE9 00000064366GE8 00000030201GE8 00000046987GE4 00000016978GE9 00000045184GE9 00000045186GE4 00000022428GE7 00000051146GE9 00000041173GE6 00000041181GE9 00000052955GE2 00000037455GE3 00000046341GE4 00000026251GE9 00000049061GE5 00000057152GE1 00000060830GE7 00000080741GE2 00000017861GE6 00000022422GE0 00000011149GE2 00000066935GE8 00000033943GE2 00000037153GE4 00000033931GE7 00000080745GE3 00000056381GE7 00000049065GE6 00000034404GE4 00000044318GE4 00000030199GE4 00000019304GE5 00000019316GE9 00000054098GE9 00000028474GE5 00000080373GE4 00000074416GE9 00000016380GE8 00000040616GE5 00000009292GE4 00000070186GE2 00000051789GE6 00000037154GE2 00000064361GE9 00000016379GE0 00000076197GE3 00000054092GE2 00000058128GE0 00000061907GE2 00000023778GE4 00000023779GE2 00000034406GE9 00000009595GE0 00000070854GE5 00000070855GE2 00000070856GE0 00000070857GE8 00000026241GE0 00000065891GE4 00000052437GE1 00000046337GE2 00000013239GE9 00000020439AW6 00000070845GE3 00000047621GE8 00000082393GE0 00000075855GE7 00000018358AW2 00000051803GE5 00000074409GE4 00000047192GE0 00000020407AW3 00000047195GE3 00000047198GE7 00000013245GE6 00000044050GE3 00000055108GE5 00000047321GE5 00000056369GE2 00000063497GE2 00000009291GE6 00000074410GE2 00000066937GE4 00000080133GE2 00000029195GE5 00000076200GE5 00000081177GE8 00000052449GE6 00000056382GE5 00000082398GE9 00000017855GE8 00000010268GE1 00000076602GE2 00000026240GE2 00000009596GE8 00000019308GE6 00000023782GE6 00000034982GE9 00000047327GE2 00000028477GE8 00000029197GE1 00000066930GE9 00000069443GE0 00000045179GE9 00000033938GE2 00000051785GE4 00000061921GE3 00000009844GE2 00000052940GE4 00000062289GE4 00000018357AW4 00000037454GE6 00000037453GE8 00000076199GE9 00000052947GE9 00000041180GE1 00000041822GE8 00000046325GE7 00000021786GE9 00000072428GE6 00000010386GE1 00000010519GE7 00000065898GE9 00000044200GE4 00000040613GE2 00000078726GE7 00000078727GE5 00000025811GE1 00000020433AW9 00000016980GE5 00000045174GE0 00000074417GE7 00000049056GE5 00000036077GE6 00000042387GE1 00000052943GE8 00000051794GE6 00000051795GE3 00000010737GE5 00000024216AW4 00000034143GE4 00000034343GE4 00000024226AW3 00000057149GE7 00000018361AW6 00000023780GE0 00000065285GE9 00000047610GE1 00000060831GE5 00000086805GE9 00000075859GE9 00000010742GE5 00000029202GE9 00000026248GE5 00000029201GE1 00000053469GE3 00000016372GE5 00000009293GE2 00000070181GE3 00000022414GE7 00000086695GE4 00000214696GE2 00000020876GE9 00000040367GE5 00000016375GE8 00000019677GE4 00000019678GE2 00000019679GE0 00000027404GE3 00000053470GE1 00000020461AW0 00000075382GE2 00000072431GE0 00000031393GE2 00000023785GE9 00000037150GE0 00000031391GE6 00000070846GE1 00000018470GE5 00000024410GE3 00000056367GE6 00000018677GE5 00000015748GE7 00000021466GE8 00000016376GE6 00000087645GE8 00000019217GE9 00000028476GE0 00000050139GE5 00000037450GE4 00000049901GE2 00000025809GE5 00000046985GE8 00000047611GE9 00000014237GE2 00000015750GE3 00000044203GE8 00000016982GE1 00000026254GE3 00000063505GE2 00000046324GE0 00000031403GE9 00000031402GE1 00000031404GE7 00000054102GE9 00000080134GE0 00000025817GE8 00000026243GE6 00000041875GE6 00000019680GE8 00000058121GE5 00000047187GE0 00000034979GE5 00000011146GE8 00000020485AW9 00000035289GE8 00000035288GE0 00000082389GE8 00000049060GE7 00000066942GE4 00000058131GE4 00000026601GE5 00000051147GE7 00000051148GE5 00000051149GE3 00000012220GE0 00000019675GE8 00000055096GE2 00000055097GE0 00000037452GE0 00000053472GE7 00000052445GE4 00000072426GE0 00000012227GE5 00000056372GE6 00000075853GE2 00000075854GE0 00000070841GE2 00000037462GE9 00000047617GE6 00000024417GE8 00000050136GE1 00000076608GE9 00000076609GE7 00000016976GE3 00000052450GE4 00000066943GE2 00000083771GE6 00000070197GE9 00000052446GE2 00000011267GE2 00000011268GE0 00000076203GE9 00000033927GE5 00000080137GE3 00000016975GE5 00000080132GE4 00000078064GE3 00000044209GE5 00000037457GE9 00000075863GE1 00000082955GE6 00000060824GE0 00000058136GE3 00000071495GE6 00000036086GE7 00000043535GE4 00000062297GE7 00000065187GE7 00000030206GE7 00000025803GE8 00000041182GE7 00000037456GE1 00000059326GE9 00000014228GE1 00000038396GE8 00000015744GE6 00000048564GE9 00000047184GE7 00000041179GE3 00000022411GE3 00000023777GE6 00000058130GE6 00000051787GE0 00000051788GE8 00000047326GE4 00000063508GE6 00000029209GE4 00000045181GE5 00000025821GE0 00000020403AW2 00000076193GE2 00000070849GE5 00000053471GE9 00000010042GE0 00000070195GE3 00000075861GE5 00000075862GE3 00000034409GE3 00000052945GE3 00000052946GE1 00000020405AW7 00000058127GE2 00000063503GE7 00000063504GE5 00000076604GE8 00000035128GE8 00000020502AW1 00000031387GE4 00000046331GE5 00000046332GE3 00000070193GE8 00000081880GE7 00000082391GE4 00000010379GE6 00000020292GE9 00000020293GE7 00000068149GE4 00000076606GE3 00000020881GE9 00000068167GE6 00000081878GE1 00000011066GE8 00000011067GE6 00000042040GE6 00000057144GE8 00000010523GE9 00000014226GE5 00000081879GE9 00000030204GE2 00000024419GE4 00000060838GE0 00000051132GE9 00000049908GE7 00000049907GE9 00000049910GE3 00000049912GE9 00000049913GE7 00000049909GE5 00000049911GE1 00000024403GE8 00000055101GE0 00000046330GE7 00000046329GE9 00000056364GE3 00000021784GE4 00000010738GE3 00000047201GE9 00000047200GE1 00000043840GE8 00000043841GE6 00000043546GE1 00000043545GE3 00000043846GE5 00000043544GE6 00000043543GE8 00000043847GE3 00000043845GE7 00000043844GE0 00000043843GE2 00000043842GE4 00000020294GE5 00000052544AW4 00000014973AW2 00000011530AW3 00000005602AW8 00000005643AW2 00000004451AW1 00000000565AW4 00000005656AW4 00000018331AW9 00000027247AW6 00000033351AW8 00000033341AW9 00000033342AW7 00000045651AW7 00000056859AW2 00000018295AW6 00000018294AW9 00000045600AW4 000000ANT21926 000000ANT20592 00000004433AW9 00000488134BU8 00000027234AW4 00000030056AW6 00000532527BU9 00000052452AW0 00000052453AW8 00000004422AW2 00000004445AW3 00000005620AW0 00000004450AW3 00000004426AW3 00000005595AW4 00000004456AW0 00000011557AW6 00000005598AW8 00000011511AW3 00000011475AW1 00000004460AW2 00000015060AW7 00000027299AW7 00000036848AW0 00000036879AW5 000000ANT25807 00000039468AW4 000000ANT20596 00000015012AW8 00000005632AW5 00000004372AW9 00000014975AW7 00000005609AW3 00000013906AW3 00000013907AW1 00000018351AW7 00000018360AW8 00000020465AW1 00000020475AW0 00000013949AW3 00000030066AW5 000000ANT20594 00000014970AW8 00000013937AW8 00000024238AW8 000000ANT25637 00000005600AW2 00000039509AW5 00000461798BU1 00000523077BU6 00000514658BU4 00000027215AW3 00000011474AW4 00000004377AW8 00000004438AW8 00000014988AW0 00000014991AW4 00000036895AW1 00000052498AW3 00000014990AW6 00000013923AW8 00000020451AW1 00000045630AW1 00000057320AW4 00000057328AW7 00000056883AW2 00000011464AW5 00000011465AW2 00000011463AW7 00000005652AW3 00000018353AW3 00000531047BU9 00000056909AW5 00000004399AW2 00000005646AW5 00000005599AW6 00000461794BU0 00000005624AW2 00000018345AW9 00000486415BU3 00000014992AW2 00000020464AW4 00000013954AW3 00000027278AW1 00000030075AW6 00000030077AW2 00000036852AW2 00000020457AW8 00000036886AW0 00000045636AW8 00000039881AW8 00000024221AW4 00000057343AW6 00000461802BU1 00000018285AW7 00000057327AW9 00000014964AW1 00000024227AW1 00000018337AW6 00000005618AW4 00000013912AW1 00000013911AW3 00000004380AW2 00000030102AW8 00000036893AW6 00000045624AW4 00000015057AW3 00000486425BU2 00000030131AW7 00000056924AW4 00000004387AW7 00000015056AW5 00000013926AW1 00000020442AW0 00000024213AW1 00000039851AW1 00000036855AW5 00000011484AW3 00000024220AW6 00000013953AW5 00000024234AW7 00000020489AW1 00000030108AW5 00000036850AW6 00000036906AW6 00000056888AW1 00000056876AW6 00000056889AW9 00000057329AW5 00000045657AW4 00000052515AW4 000000ANT20824 000000ANT20603 00000005597AW0 00000020488AW3 00000036877AW9 00000013913AW9 00000013920AW4 00000027282AW3 00000027216AW1 00000030095AW4 00000036899AW3 00000045570AW9 00000057345AW1 00000057382AW4 00000461797BU3 00000013917AW0 00000024229AW7 00000024248AW7 00000030062AW4 00000027297AW1 00000030055AW8 00000027304AW5 00000014969AW0 00000030087AW1 00000030073AW1 00000039452AW8 00000056855AW0 00000057347AW7 00000057388AW1 000000ANT21796 00000004440AW4 00000004411AW5 00000005573AW1 00000014972AW4 00000014986AW4 00000024231AW3 00000030071AW5 00000030068AW1 00000030107AW7 00000057372AW5 00000005627AW5 00000005608AW5 00000013881AW8 00000033288AW2 00000027301AW1 00000057337AW8 00000045635AW0 00000057344AW4 00000057319AW6 00000013870AW1 00000020490AW9 00000039824AW8 00000045626AW9 00000013928AW7 00000045602AW0 00000039485AW8 00000052509AW7 00000057380AW8 00000057321AW2 000000ANT20898 00000005649AW9 00000013962AW6 00000057397AW2 00000036892AW8 00000036836AW5 00000013943AW6 00000005639AW0 00000004404AW0 00000011535AW2 00000020404AW0 00000020477AW6 00000027217AW9 00000036897AW7 00000045607AW9 00000045620AW2 00000039472AW6 00000039486AW6 00000020476AW8 00000036882AW9 00000045581AW6 00000057346AW9 00000057383AW2 00000057350AW1 00000011469AW4 00000045584AW0 000000ANT20598 000000ANT20901 000000ANT20600 000000ANT20601 00000052521AW2 00000052508AW9 00000052535AW2 00000013946AW9 00000004437AW0 00000020411AW5 00000036918AW1 00000039857AW3 000000ANT20896 00000011553AW5 00000039506AW1 00000052530AW3 00000030144AW0 00000030145AW7 00000018310AW3 00000027230AW2 00000033294AW0 00000057302AW2 00000036911AW6 00000036860AW5 00000033318AW7 00000515067BU7 00000014995AW5 00000033275AW9 00000488147BU0 00000005571AW5 00000004382AW8 00000052514AW7 00000005641AW6 00000027207AW0 00000057311AW3 00000033298AW1 00000052471AW0 00000030057AW4 00000030086AW3 00000057306AW3 00000033325AW2 00000004386AW9 00000005574AW9 00000005623AW4 00000004429AW7 00000015034AW2 00000033312AW0 00000005650AW7 00000004385AW1 00000004375AW2 00000036902AW5 00000005578AW0 00000039495AW7 00000004436AW2 00000005592AW1 00000004452AW9 00000005629AW1 00000005614AW3 00000005633AW3 00000005628AW3 00000011508AW9 00000011501AW4 00000011496AW7 00000011539AW4 00000011556AW8 00000014963AW3 00000004364AW6 00000013864AW4 00000011505AW5 00000463058BU8 00000013885AW9 00000013918AW8 00000013902AW2 00000013899AW0 00000014998AW9 00000020437AW0 00000013927AW9 00000015028AW4 00000011541AW0 00000015013AW6 00000013940AW2 00000486420BU3 00000018278AW2 00000015040AW9 00000018319AW4 00000018275AW8 00000015061AW5 00000018265AW9 00000015020AW1 00000011558AW4 00000015043AW3 00000020444AW6 00000020416AW4 00000027232AW8 00000486428BU6 00000011497AW5 00000024247AW9 00000020431AW3 00000018276AW6 00000024212AW3 00000486418BU7 00000024219AW8 00000486429BU4 00000486417BU9 00000488140BU5 00000027245AW0 00000515342BU4 00000039858AW6 00000486416BU1 00000024241AW2 00000039477AW5 00000027253AW4 00000039479AW1 00000027266AW6 00000027242AW7 00000488141BU3 00000027286AW4 00000027274AW0 00000027226AW0 00000027209AW6 00000027295AW5 00000030096AW2 00000027263AW3 00000040369GE1 00000030076AW4 00000027285AW6 00000027236AW9 00000030104AW4 00000045650AW9 00000030093AW9 00000045648AW3 00000030069AW9 00000030064AW0 00000030063AW2 00000033255AW1 00000030072AW3 00000027292AW2 00000045659AW0 00000030109AW3 00000030147AW3 00000033256AW9 00000033257AW7 00000033319AW5 00000027293AW0 00000045658AW2 00000027262AW5 00000039444AW5 00000030127AW5 00000033286AW6 00000030153AW1 00000030154AW9 00000033297AW3 00000033279AW1 00000030150AW7 00000036890AW2 00000033315AW3 00000036874AW6 00000036831AW6 00000036863AW9 00000033299AW9 00000033343AW5 00000033328AW6 00000033293AW2 00000036891AW0 00000033289AW0 00000514656BU8 00000036914AW0 00000036919AW9 00000039437AW9 00000039435AW3 00000039879AW2 00000039825AW5 00000039828AW9 00000039832AW1 00000036900AW9 00000036903AW3 00000039424AW7 00000039489AW0 00000039510AW3 00000514650BU1 00000045574AW1 00000039473AW4 00000039483AW3 00000045582AW4 00000045625AW1 00000045611AW1 00000523082BU6 00000523107BU1 00000045571AW7 00000532515BU4 00000523106BU3 00000039502AW0 00000039475AW9 00000045628AW5 00000045641AW8 00000045608AW7 00000045603AW8 00000045590AW7 00000045661AW6 00000045640AW0 00000045615AW2 00000045643AW4 00000045595AW6 00000039469AW2 00000045594AW9 00000045664AW0 00000052467AW8 00000531046BU1 00000052466AW0 00000039490AW8 00000045592AW3 00000045576AW6 00000052533AW7 00000045585AW7 00000056851AW9 00000052542AW8 00000056852AW7 00000057303AW0 00000532530BU3 00000532528BU7 00000045665AW7 00000052458AW7 00000045655AW8 00000052500AW6 00000045618AW6 00000052523AW8 00000045598AW0 00000057336AW0 00000057352AW7 00000056894AW9 00000056896AW4 00000057335AW2 00000057351AW9 00000057301AW4 00000056870AW9 00000056878AW2 00000056895AW6 00000052507AW1 00000056897AW2 00000057340AW2 00000056921AW0 00000057395AW6 00000056917AW8 00000056941AW8 00000056936AW8 00000056947AW5 00000056928AW5 00000056914AW5 000000ANT20591 000000ANT21738 00000057362AW6 000000ANT21310 000000ANT21190 000000ANT21528 00000532516BU2 00000030142AW4 00000005625AW9 00000011504AW8 00000027237AW7 00000005579AW8 00000045588AW1 00000052491AW8 00000005584AW8 00000463062BU0 00000463067BU9 00000011466AW0 00000013901AW4 00000013878AW4 00000005640AW8 00000014983AW1 00000027212AW0 00000020497AW4 00000515072BU7 00000057357AW6 00000039504AW6 00000030089AW7 00000515066BU9 00000045642AW6 00000039501AW2 00000039877AW6 00000056923AW6 00000056874AW1 00000056867AW5 000000ANT21519 00000056902AW0 00000056904AW6 00000057392AW3 00000039428AW8 00000011533AW7 00000011532AW9 00000005642AW4 00000024237AW0 00000027283AW1 00000052478AW5 00000030117AW6 00000039487AW4 00000036834AW0 000000ANT25639 000000ANT25565 00000004394AW3 00000488139BU7 00000488145BU4 00000488144BU7 00000033332AW8 00000033335AW1 00000530430BU8 00000018301AW2 00000056866AW7 00000057389AW9 00000018288AW1 00000018266AW7 00000011480AW1 00000004449AW5 00000011516AW2 00000015007AW8 00000036853AW0 00000057332AW9 00000018327AW7 00000011473AW6 00000005619AW2 00000011472AW8 00000013957AW6 00000024250AW3 00000011540AW2 00000514653BU5 00000030130AW9 00000039513AW7 00000530440BU7 00000052540AW2 00000056908AW7 00000056926AW9 00000024254AW5 00000039426AW2 00000015002AW9 000000ANT20503 000000ANT20502 000000ANT20507 00000045609AW5 00000014965AW8 00000011476AW9 00000011479AW3 00000011478AW5 00000056939AW2 00000005655AW6 00000052529AW5 00000011520AW4 00000011526AW1 00000030059AW0 00000030060AW8 00000056873AW3 00000039511AW1 00000015055AW7 00000015050AW8 00000015054AW0 00000015051AW6 00000018286AW5 00000013875AW0 00000013932AW9 00000013930AW3 00000036841AW5 00000013919AW6 00000024232AW1 00000024233AW9 00000005662AW2 00000005661AW4 00000018274AW1 00000020414AW9 00000036842AW3 00000036843AW1 00000036839AW9 00000523109BU7 00000523110BU5 00000013894AW1 00000013882AW6 00000057366AW7 00000036833AW2 00000039846AW1 00000004439AW6 00000011525AW3 00000018267AW5 00000018268AW3 00000004413AW1 00000014971AW6 00000014974AW0 00000013931AW1 00000013945AW1 00000039421AW3 00000033349AW2 00000033347AW6 00000486412BU0 00000011495AW9 00000013936AW0 00000045663AW2 00000004407AW3 000000ANT23227 00000013868AW5 00000056931AW9 00000020446AW1 00000027288AW0 00000532514BU7 00000039494AW0 000000ANT20978 00000011477AW7 00000036909AW0 00000011529AW5 00000018264AW2 00000013903AW0 00000004369AW5 00000015047AW4 00000036866AW2 000000ANT23831 00000024239AW6 00000045614AW5 00000052455AW3 00000052456AW1 00000052527AW9 00000052525AW3 00000011534AW5 000000ANT22041 000000ANT21795 00000057309AW7 00000057310AW5 00000057307AW1 00000014979AW9 00000005612AW7 00000039434AW6 00000036825AW8 00000027235AW1 00000011517AW0 00000005568AW1 00000011507AW1 00000005610AW1 00000045647AW5 00000013947AW7 00000013948AW5 00000024218AW0 00000486424BU5 00000530703BU8 00000027255AW9 00000030148AW1 00000011519AW6 00000004383AW6 00000052516AW2 00000033326AW0 00000013891AW7 00000005607AW7 00000033323AW7 00000052483AW5 00000052512AW1 00000033339AW3 00000033336AW9 00000033309AW6 00000045591AW5 00000014977AW3 00000015003AW7 00000052517AW0 00000020466AW9 00000461799BU9 00000004428AW9 00000052519AW6 00000005638AW2 00000013884AW2 00000013890AW9 00000011503AW0 00000020421AW4 000000ANT21521 000000ANT21927 00000052492AW6 00000052487AW6 00000052463AW7 00000005651AW5 00000039830AW5 00000039476AW7 00000015058AW1 00000033307AW0 00000045660AW8 00000018282AW4 00000036844AW9 00000020445AW3 00000039503AW8 00000033274AW2 00000036881AW1 00000013874AW3 00000018347AW5 00000033290AW8 00000056922AW8 00000056857AW6 00000056913AW7 00000056940AW0 00000056911AW1 00000004370AW3 00000011518AW8 00000052490AW0 00000530702BU0 00000011487AW6 00000515337BU4 00000027287AW2 00000052464AW5 00000039451AW0 00000011528AW7 00000488136BU3 00000027213AW8 00000515341BU6 00000039855AW2 00000056890AW7 00000027261AW7 00000039497AW3 00000036867AW0 00000036820AW9 00000015004AW5 00000015005AW2 00000056893AW1 00000056903AW8 00000024240AW4 00000018315AW2 00000020472AW7 00000020467AW7 00000020492AW5 00000020419AW8 00000020481AW8 00000020493AW3 00000020420AW6 00000027241AW9 00000027240AW1 00000013865AW1 00000011493AW4 00000005621AW8 00000030133AW3 00000033337AW7 00000027259AW1 00000027244AW3 00000523108BU9 00000015023AW5 00000011514AW7 00000530705BU3 00000530706BU1 00000045596AW4 00000530439BU9 00000052454AW6 00000018323AW6 00000018322AW8 00000018321AW0 00000018305AW3 00000027218AW7 00000033352AW6 00000039862AW8 00000515333BU3 00000039443AW7 00000039442AW9 00000461801BU3 00000018338AW4 00000033287AW4 000000ANT26074 000000ANT26076 000000ANT21311 00000039847AW9 00000039450AW2 00000014967AW4 00000039873AW5 00000013915AW4 00000027238AW5 00000039843AW8 00000004432AW1 00000039461AW9 00000039460AW1 00000033271AW8 00000033272AW6 00000033273AW4 00000033278AW3 00000011560AW0 00000033258AW5 00000033277AW5 00000463061BU2 00000033284AW1 00000011552AW7 00000011550AW1 00000011548AW5 00000036901AW7 00000036837AW3 00000052475AW1 00000045612AW9 00000004457AW8 00000013866AW9 00000013867AW7 00000039868AW5 00000039880AW0 000000ANT22007 00000045578AW2 00000039865AW1 00000515340BU8 00000011488AW4 00000011489AW2 00000463064BU6 00000056905AW3 00000005654AW9 00000039874AW3 00000013886AW7 00000011542AW8 00000004444AW6 00000018299AW8 00000004421AW4 00000005575AW6 00000052506AW3 00000052497AW5 00000020491AW7 00000020486AW7 00000005563AW2 00000011524AW6 00000011513AW9 00000004425AW5 00000005581AW4 00000005580AW6 00000005583AW0 00000030137AW4 00000530437BU3 00000056932AW7 00000005606AW9 00000039433AW8 00000461800BU5 00000039430AW4 00000039823AW0 00000039854AW5 00000020500AW5 00000024205AW7 00000027294AW8 00000027291AW4 00000027257AW5 00000039493AW2 00000039454AW4 00000052481AW9 00000004378AW6 00000033265AW0 00000011546AW9 00000011545AW1 00000015035AW9 00000039465AW0 00000039481AW7 00000030088AW9 00000018326AW9 00000033296AW5 00000033295AW7 00000018277AW4 00000005569AW9 00000004412AW3 00000033321AW1 00000033327AW8 00000515335BU8 00000515338BU2 00000015036AW7 00000015049AW0 00000024225AW5 00000004381AW0 00000004417AW2 00000018304AW6 00000030152AW3 00000532518BU8 00000011494AW2 000000ANT25560 00000027251AW8 00000004455AW2 00000057393AW1 00000057385AW7 00000004454AW5 00000005586AW3 00000015037AW5 00000020487AW5 00000018329AW3 00000018328AW5 00000011491AW8 00000013924AW6 00000013925AW3 00000036862AW1 00000027272AW4 00000027271AW6 00000015039AW1 00000045605AW3 00000036876AW1 00000036849AW8 00000057375AW8 00000057368AW3 00000005615AW0 00000004403AW2 00000020432AW1 00000015033AW4 00000018352AW5 00000056899AW8 00000056927AW7 00000004420AW6 00000005590AW5 00000011523AW8 00000005589AW7 00000018283AW2 00000018271AW7 00000018273AW3 00000018272AW5 00000004388AW5 00000515063BU6 00000036904AW1 00000036905AW8 00000036907AW4 00000515064BU4 00000515071BU9 00000030081AW4 00000039462AW7 00000039463AW5 00000057394AW9 00000013952AW7 00000013944AW4 00000039852AW9 00000039482AW5 00000039498AW1 00000005585AW5 00000005645AW7 00000005644AW0 00000036822AW5 00000036823AW3 00000011470AW2 00000011471AW0 00000013879AW2 0 000000ANT22352 00000033330AW2 00000033314AW6 00000033311AW2 00000033322AW9 00000056885AW7 00000015006AW0 00000015001AW1 00000015014AW4 00000039882AW6 00000039876AW8 00000052472AW8 00000532519BU6 00000004441AW2 00000004442AW0 00000014968AW2 00000005637AW4 00000005631AW7 00000005658AW0 00000013929AW5 00000013938AW6 00000039456AW9 00000027211AW2 00000027275AW7 00000057384AW0 00000056856AW8 00000004390AW1 00000004384AW4 00000027302AW9 00000004443AW8 00000039441AW1 00000056929AW3 00000056881AW6 00000011527AW9 00000020448AW7 00000027210AW4 00000462624BU8 00000463066BU1 00000030128AW3 00000013922AW0 00000013921AW2 00000039423AW9 00000027281AW5 00000027280AW7 00000027296AW3 00000004461AW0 00000005603AW6 00000015017AW7 00000039420AW5 00000039835AW4 00000515068BU5 00000015011AW0 00000013956AW8 00000052537AW8 00000036887AW8 00000005565AW7 00000018308AW7 00000018307AW9 00000018309AW5 00000036917AW3 00000039848AW7 00000039849AW5 00000039833AW9 00000039838AW8 00000005653AW1 00000011510AW5 00000033310AW4 00000015048AW2 00000018292AW3 00000039422AW1 00000015024AW3 00000052460AW3 00000056879AW0 00000056880AW8 00000033266AW8 00000045627AW7 00000030094AW7 00000018289AW9 00000052470AW2 00000027270AW8 00000004459AW4 00000057356AW8 00000014978AW1 00000011490AW0 00000039867AW7 00000039474AW2 00000018320AW2 00000488137BU1 00000488152BU0 00000039840AW4 00000514655BU0 00000514652BU7 00000005660AW6 00000052495AW9 00000052526AW1 000000ANT21193 00000057371AW7 00000036830AW8 00000039850AW3 00000011547AW7 00000014989AW8 00000045633AW5 00000020456AW0 00000005594AW7 00000056915AW2 00000030135AW8 00000027246AW8 00000004397AW6 00000027206AW2 00000018293AW1 00000018349AW1 00000030092AW1 00000532520BU4 00000004363AW8 00000027265AW8 00000033340AW1 00000015062AW3 00000015021AW9 00000015022AW7 00000057318AW8 00000530441BU5 00000056861AW8 00000027223AW7 00000052461AW1 00000010950AW4 00000013889AW1 00000039831AW3 00000030149AW9 00000039507AW9 00000045619AW4 00000005593AW9 00000033313AW8 00000531040BU4 00000033338AW5 00000052513AW9 00000039837AW0 00000036872AW0 00000011543AW6 00000011531AW1 00000039842AW0 00000013880AW0 00000005564AW0 00000020440AW4 00000039484AW1 00000013909AW7 00000005588AW9 00000530434BU0 00000057399AW8 000000ANT20504 00000030105AW1 00000013908AW9 00000030134AW1 00000036869AW6 00000030129AW1 00000011522AW0 00000011521AW2 00000488146BU2 00000045667AW3 00000530438BU1 00000052451AW2 00000033283AW3 00000004424AW8 00000531044BU6 00000014987AW2 00000005617AW6 00000045572AW5 00000027300AW3 00000488138BU9 00000027256AW7 00000011498AW3 00000462626BU3 00000462627BU1 000000ANT22045 00000514659BU2 00000514657BU6 00000027264AW1 00000462633BU9 00000020413AW1 00000039866AW9 00000039455AW1 00000033334AW4 00000013892AW5 00000013900AW6 00000013897AW4 00000013883AW4 00000018354AW1 00000011485AW0 00000057364AW2 000000ANT21793 00000039829AW7 00000045653AW3 00000027205AW4 00000027214AW6 00000018300AW4 00000018325AW1 00000018297AW2 00000033282AW5 00000486411BU2 00000018333AW5 00000018334AW3 00000024236AW2 00000011515AW4 00000033316AW1 00000005570AW7 00000052503AW0 00000014996AW3 00000004434AW7 00000015025AW0 00000020415AW6 00000020425AW5 00000020412AW3 00000486410BU4 00000486426BU0 00000027279AW9 00000033269AW2 00000039447AW8 00000052476AW9 00000030122AW6 00000052502AW2 00000052493AW4 00000056935AW0 00000005636AW6 00000020447AW9 00000027252AW6 00000015046AW6 00000461793BU2 00000039519AW4 00000033304AW7 00000036888AW6 00000004402AW4 00000013935AW2 00000013916AW2 00000056945AW9 000000ANT22040 00000530442BU3 00000013950AW1 00000013893AW3 00000057359AW2 00000057358AW4 00000057360AW0 00000020418AW0 00000020417AW2 00000018306AW1 00000004368AW7 00000004401AW6 00000056944AW2 00000018296AW4 00000004423AW0 00000004431AW3 00000030141AW6 00000036875AW3 00000033285AW8 00000036865AW4 00000033350AW0 00000036828AW2 00000488149BU6 00000532522BU0 000000ANT20975 00000027239AW3 00000036861AW3 00000036859AW7 00000036847AW2 00000486419BU5 00000039512AW9 00000039518AW6 00000033308AW8 00000033317AW9 00000014966AW6 00000005647AW3 00000005648AW1 00000024253AW7 00000014982AW3 00000014981AW5 00000014980AW7 00000004392AW7 00000045579AW0 00000027303AW7 00000018335AW0 00000018336AW8 00000018339AW2 00000011482AW7 00000014993AW0 00000014994AW8 00000052532AW9 00000036870AW4 00000030100AW2 00000030120AW0 00000039836AW2 00000045599AW8 00000004414AW9 00000018263AW4 00000018270AW9 00000033345AW0 00000020460AW2 00000033264AW3 00000027208AW8 00000039500AW4 00000027290AW6 00000015041AW7 00000024252AW9 00000052482AW7 00000036868AW8 00000005567AW3 00000018269AW1 00000036854AW8 
Recalling Firm/
Manufacturer
GE Healthcare
3000 N Grandview Blvd
Waukesha WI 53188-1615
For Additional Information Contact
262-544-3894
Manufacturer Reason
for Recall
Aortic Length over-estimated: incorrect measurements when using the Aorta analysis protocol or customized protocols. Until a new software version is installed the aorta analysis protocol or the customized protocols for an aneurysm should NOT BE USED.
FDA Determined
Cause 2
Software design
Action An Urgent Safety Notice to customers dated 9/10/07, was issued by the recalling firm informing them of the device defect, safety issues, warnings on future uses and promised new software updates to be installed by GE representatives, free of charge, beginning Nov. 2007.
Quantity in Commerce 2,518
Distribution Worldwide Distribution - USA including states of AK, AL, AR, AZ, CA, CO, CT, CU, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, PR, RI, SC, SD, TN, TX, UT, VA, WA, WI, WY, and Guam, and countries of Canada, Mexico. Argentina, Brazil, Chile, Colombia, Dominican Republic, Ecuador, Australia, China, Honk Kong, Indonesia, Japan, Korea, New Zealand, Singapore, Thailand, Taiwan, United Arab Emirates, Albania, Austria, Azerbaijan, Bosnia, Belgium, Belarus, Switzerland, Czech Republic, Germany, Denmark, Egypt, Spain, Finland, France, Great Britain, Guadeloupe, Greece, Hungary , Ireland, Israel, Italy, Kuwait, Lebanon, Morocco, Netherlands, Norway, French Polynesia, Poland, Portugal, Russian Federation, Saudi Arabia, Sweden, Slovenia, Tunisia, Turkey, and South Africa.
Total Product Life Cycle TPLC Device Report

1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
510(K) Database 510(K)s with Product Code = LLZ and Original Applicant = GE HEALTHCARE
510(K)s with Product Code = LLZ and Original Applicant = GE MEDICAL SYSTEMS
-
-