Class 1 Device Recall Spectrum Central Venous Catheter Tray, Minocycline/Rifampin Antibiotic Impregnated, 5 Lumen |
|
Date Initiated by Firm |
October 04, 2010 |
Date Posted |
February 23, 2011 |
Recall Status1 |
Terminated 3 on June 21, 2011 |
Recall Number |
Z-1126-2011 |
Recall Event ID |
57663 |
510(K)Number |
K081113
|
Product Classification |
Peripherally Inserted, Central Venous Catheter Tray - Product Code FOZ
|
Product |
Spectrum Central Venous Catheter Tray, Minocycline/Rifampin Antibiotic Impregnated, Double Lumen Polyurethane, 4.0 Fr/12 cm, C-UDLMY-401J- RSC-ABRM-HC-FST, G43993, Sterile, Cook Medical, Cook Incorporated, Bloomington, IN. |
Code Information |
Part Number: C-UDLMY-401J-RSC- ABRM-HC-FST; Global Part Number G43993, lots 2239672, 2240535, 2242733, 2247662, 2248313, 2252474, 2254446, 2256875, 2259331, 2262108, 2262211, 2275423, 2276823, 2282408, 2290114, 2291776, 2300741, 2315939, 2318834 and 2330565. |
Recalling Firm/ Manufacturer |
Cook, Inc. 750 Daniels Way Bloomington IN 47404-9120
|
For Additional Information Contact |
Rita A. Harden 812-339-2235
|
Manufacturer Reason for Recall |
Cook, Inc. is recalling Single, Double, Triple, and Five-Lumen Central Venous Catheter Trays AND Single and Double Lumen PICC Peripherally Inserted Central Venous Catheter Trays. These kits and trays contain 0.9% Sodium Chloride Injection USP 5 mL fill in 6 mL flush syringes that have been recalled by Excelsior Medical. During a routine test for syringe sterility, a possible integrity failure wa
|
FDA Determined Cause 2 |
Nonconforming Material/Component |
Action |
Cook, Inc. sent URGENT DEVICE RECALLS letters to its customers dated 10/4/2010. The letters asked customers to examine their inventory and notify Cook for product return. The letter included a response form. |
Quantity in Commerce |
51,473 total kits/trays |
Distribution |
Worldwide distribution: USA, Chile, Colombia, Panama, Barbados, Canada, Guatemala, and Saudi Arabia. |
Total Product Life Cycle |
TPLC Device Report
|
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
|
510(K) Database |
510(K)s with Product Code = FOZ and Original Applicant = COOK, INC.
|
|
|
|