07/15/2019 |
Anesthesiology |
1-143 |
Complete |
ISO |
80601-2-79 First edition 2018-07 |
Medical electrical equipment - Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment |
12/21/2020 |
ObGyn/ Gastroenterology/ Urology |
9-130 |
Complete |
ISO |
8600-6 Second edition 2020-09 |
Endoscopes - Medical endoscopes and endotherapy devices - Part 6: Vocabulary |
12/23/2019 |
General I (QS/ RM) |
5-124 |
Complete |
ISO |
7000 Sixth edition 2019-07 |
Graphical symbols for use on equipment - Registered symbols |
12/23/2019 |
Radiology |
12-328 |
Complete |
IEC |
61223-3-5 Edition 2.0 2019-09 |
Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment [Including: Technical Corrigendum 1 (2006)] |
01/14/2019 |
Radiology |
12-102 |
Complete |
ANSI IES |
RP-27.2-00/R17 |
Recommended Practice for Photobiological Safety for Lamps and Lamp Systems - Measurement Techniques |
01/14/2019 |
Radiology |
12-321 |
Complete |
ANSI IES |
RP-27.3-17 |
Recommended Practice for Photobiological Safety for Lamps - Risk Group Classification and Labeling |
07/06/2020 |
InVitro Diagnostics |
7-298 |
Complete |
CLSI |
EP35, 1st Edition |
Assessment of Equivalence or Suitability of Specimen Types for Medical Laboratory Measurement Procedures |
01/14/2019 |
General I (QS/ RM) |
5-122 |
Complete |
ASME |
V&V 40-2018 |
Assessing Credibility of Computational Modeling Through Verification and Validation: Application to Medical Devices |
01/14/2019 |
Cardiovascular |
3-158 |
Complete |
ASTM |
F3320-18 |
Standard Guide forCoating Characterization of Drug Coated Balloons |
01/14/2019 |
Dental/ ENT |
4-255 |
Complete |
ANSI ADA |
Standard No. 131-2015 (R2020) |
Dental CAD/CAM Machinable Zirconia Blanks |
07/15/2019 |
Orthopedic |
11-355 |
Complete |
ISO |
15142-1 First edition 2003-08-01 |
Implants for surgery - Metal intramedullary nailing systems - Part 1: Intramedullary nails |
07/06/2020 |
Cardiovascular |
3-164 |
Complete |
ASTM |
F1830-19 |
Standard Practice for Collection and Preparation of Blood for Dynamic In Vitro Evaluation of Blood Pumps |
03/16/2012 |
Radiology |
12-115 |
Complete |
ISO |
13695:2004 |
Optics and photonics - Lasers and laser-related equipment - Test methods for the spectral characteristics of lasers |
12/23/2016 |
Radiology |
12-303 |
Complete |
IEC |
61303 Edition 1.0 1994-09 |
Medical electrical equipment - Radionuclide calibrators - Particular methods for describing performance [Including CORRIGENDUM 1 (2016)] |
12/23/2016 |
Radiology |
12-304 |
Complete |
IEC |
60731 Edition 3.1 2016-04 |
Consolidated Version Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy |
09/09/2008 |
Software/ Informatics |
13-18 |
Complete |
CLSI |
LIS03-A |
Standard Guide for Selection of a Clinical Laboratory Information Management System |
12/23/2019 |
Materials |
8-492 |
Complete |
ISO |
5832-9 Third edition 2019-02 |
Implants for surgery - Metallic materials - Part 9: Wrought high nitrogen stainless steel |
06/07/2021 |
Ophthalmic |
10-126 |
Complete |
IEC |
80601-2-58 Edition 2.0 2014-09 |
Medical electrical equipment - Part 2-58: Particular requirements for basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery [Including AMENDMENT 1 (2016)] |
ANSI AAMI IEC |
80601-2-58:2014 |
Medical electrical equipment - Part 2-58: Particular requirements for basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery [Including AMENDMENT 1 (2016)] |
07/06/2020 |
General Plastic Surgery/ General Hospital |
6-444 |
Complete |
ASTM |
D7103-19(2023) |
Standard Guide for Assessment of Medical Gloves |
07/06/2020 |
Anesthesiology |
1-146 |
Complete |
ISO |
80601-2-12 Second edition 2020-02 |
Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators |
12/21/2020 |
Nanotechnology |
18-17 |
Complete |
ISO |
21363 First edition 2020-06 |
Nanotechnologies - Measurements of particle size and shape distributions by transmission electron microscopy |
12/21/2020 |
Biocompatibility |
2-278 |
Complete |
ASTM |
F719-20 e1 |
Standard Practice for Testing Materials in Rabbits for Primary Skin Irritation |
07/09/2014 |
Software/ Informatics |
13-68 |
Complete |
ISO |
11073-90101 First edition 2008-01-15 |
Health informatics - Point-of-care medical device communication - Part 90101: Analytical instruments -- Point-of-care test |
04/04/2016 |
Software/ Informatics |
13-81 |
Complete |
IEEE |
Std 11073-10419:2015 |
Health informatics - Personal health device communication - Part 10419: Device Specialization - Insulin Pump |
07/15/2019 |
Materials |
8-510 |
Complete |
ASTM |
F997-18 |
Standard Specification for Polycarbonate Resin for Medical Applications |
12/23/2019 |
Materials |
8-505 |
Complete |
ISO |
6474-2 Second edition 2019-03 |
Implants for surgery - Ceramic materials - Part 2: Composite materials based on a high-purity alumina matrix with zirconia reinforcement |
12/23/2019 |
Materials |
8-507 |
Complete |
ASTM |
F688-19 |
Standard Specification for Wrought Cobalt-35Nickel-20Chromium-10Molybdenum Alloy Plate, Sheet, and Foil for Surgical Implants (UNS R30035) |
08/14/2015 |
Software/ Informatics |
13-76 |
Complete |
ISO |
11073-91064 First edition 2009-05-01 |
Health informatics - Standard communication protocol - Computer-assisted electrocardiography |
07/06/2020 |
ObGyn/ Gastroenterology/ Urology |
9-124 |
Complete |
CIE ISO |
11664-1:2019 |
Colorimetry - Part 1: CIE standard colorimetric observers |
08/21/2017 |
Software/ Informatics |
13-94 |
Complete |
ISO IEEE |
11073-10424 First edition 2016-06-15 |
Health informatics - Personal health device communication - Part 10424: Device specialization - Sleep Apnoea Breathing Therapy Equipment (SABTE) [Including TECHNICAL CORRIGENDUM 1 (2018)] |
08/06/2013 |
Software/ Informatics |
13-49 |
Complete |
ISO IEEE |
11073-20101 First edition 2004-12-15 |
Health informatics - Point-of-care medical device communication - Part 20101: Application Profiles - Base Standard |
07/09/2014 |
Radiology |
12-275 |
Complete |
IEC |
61161 Edition 3.0 2013-01 |
Ultrasonics -- Power measurement -- Radiation force balances and performance requirements |
07/09/2014 |
Radiology |
12-280 |
Complete |
IEC |
62555 Edition 1.0 2013-11 |
Ultrasonics -- Power measurement -- High intensity therapeutic ultrasound (HITU) transducers and systems |
07/09/2014 |
Radiology |
12-281 |
Complete |
IEC |
60601-2-62 Edition 1.0 2013-07 |
Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
07/06/2020 |
ObGyn/ Gastroenterology/ Urology |
9-129 |
Complete |
ISO CIE |
61966-2-1 First edition 1999-10 |
Multimedia systems and equipment - Colour measurement and management - Part 2-1: Colour management - Default RGB colour space - sRGB [Including: Amendment 1 (2003) and Corrigendum 1 (2014)] |
12/23/2019 |
Materials |
8-520 |
Complete |
ASTM |
F799-19 |
Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Forgings for Surgical Implants (UNS R31537, R31538, R31539) |
12/21/2020 |
Sterility |
14-554 |
Complete |
ASTM |
F17-20 |
Standard Terminology Relating to Flexible Barrier Packaging |
12/23/2019 |
General Plastic Surgery/ General Hospital |
6-424 |
Complete |
ASTM |
D5151-19(2023) |
Standard Test Method for Detection of Holes in Medical Gloves |
10/04/2004 |
InVitro Diagnostics |
7-104 |
Complete |
CLSI |
H7-A3 |
Procedure for Determining Packed Cell Volume by the Microhematocrit Method - Second Edition; Approved Standard - Third Edition. |
03/18/2009 |
InVitro Diagnostics |
7-180 |
Complete |
CLSI |
M34-A (Replaces M24-P) |
Western Blot Assay for Antibodies to Borrelia burgdorferi; Approved Guideline. |
10/04/2010 |
InVitro Diagnostics |
7-212 |
Complete |
CLSI |
EP18-A2 |
Risk Management Techniques to Identify and Control Laboratory Error Sources; Approved Guideline - Second Edition |
03/16/2012 |
Radiology |
12-134 |
Complete |
ISO |
11146-1 First edition 2005-01-15 |
Lasers and laser-related equipment - Test methods for laser beam widths, divergence angles and beam propagation ratios - Part 1: Stigmatic and simple astigmatic beams |
07/09/2014 |
Sterility |
14-282 |
Complete |
ASTM |
F2338-09 (Reapproved 2020) |
Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method |
08/06/2013 |
Ophthalmic |
10-78 |
Complete |
ISO |
11979-3 Third edition 2012-12-01 |
Ophthalmic implants - Intraocular lenses - Part 3: Mechanical properties and test methods |
01/30/2014 |
General Plastic Surgery/ General Hospital |
6-305 |
Complete |
ISO |
10555-3 Second edition 2013-06-15 |
Intravascular catheters -- Sterile and single-use catheters -- Part 3: Central venous catheters |
01/30/2014 |
Sterility |
14-405 |
Complete |
ASTM |
F2252/F2252M-13 (Reapproved 2018) |
Standard Practice for Evaluating Ink or Coating Adhesion to Flexible Packaging Materials Using Tape |
08/14/2015 |
ObGyn/ Gastroenterology/ Urology |
9-108 |
Complete |
ISO |
8009 Second edition 2014-11-15 |
Mechanical contraceptives - Reusable natural and silicone rubber contraceptive diaphragms - Requirements and tests |
09/17/2018 |
Orthopedic |
11-337 |
Complete |
ISO |
16087 First edition 2013-10-01 |
Implants for surgery - Roentgen stereophotogrammetric analysis for the assessment of migration of orthopaedic implants |
09/09/2008 |
Radiology |
12-166 |
Complete |
NEMA |
XR 23-2006 (R2020) |
"Quality Control Manual" Template for Manufacturers of Hardcopy Output Devices Labeled for Final Interpretation in Full-field Digital Mammography |
10/04/2010 |
Radiology |
12-213 |
Complete |
IEC |
62220-1-2 Edition 1.0 2007-06 |
Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography |