• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

TPLC - Total Product Life Cycle

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

New Search show TPLC since Back to Search Results
Device restraint, protective
Product CodeFMQ
Regulation Number 880.6760
Device Class 1


Premarket Reviews
ManufacturerDecision
CHILDREN'S HEALTH FIRST, INC.
  SUBSTANTIALLY EQUIVALENT 1
MEDI-TECH INTL. CORP.
  SUBSTANTIALLY EQUIVALENT 1

MDR Year MDR Reports MDR Events
2014 43 43
2015 33 33
2016 24 24
2017 54 54
2018 23 23
2019 57 57
2020 38 38
2021 33 33
2022 54 54
2023 47 47
2024 42 42

Device Problems MDRs with this Device Problem Events in those MDRs
Break 125 125
Adverse Event Without Identified Device or Use Problem 47 47
Device Slipped 43 43
Mechanical Problem 30 30
Insufficient Information 18 18
Material Split, Cut or Torn 15 15
Device Operates Differently Than Expected 14 14
Torn Material 13 13
Material Integrity Problem 12 12
Improper or Incorrect Procedure or Method 12 12
Device Contaminated During Manufacture or Shipping 11 11
Defective Device 9 9
Material Separation 9 9
Defective Component 8 8
Patient Device Interaction Problem 7 7
Detachment Of Device Component 7 7
Product Quality Problem 6 6
Detachment of Device or Device Component 6 6
Mechanics Altered 6 6
Positioning Problem 5 5
Labelling, Instructions for Use or Training Problem 5 5
Material Frayed 5 5
Material Disintegration 4 4
Difficult to Open or Close 4 4
Human-Device Interface Problem 4 4
Misassembled 4 4
Material Rupture 4 4
Fail-Safe Problem 3 3
Stretched 3 3
Use of Device Problem 3 3
Connection Problem 3 3
Appropriate Term/Code Not Available 2 2
Protective Measures Problem 2 2
Therapeutic or Diagnostic Output Failure 2 2
No Apparent Adverse Event 2 2
Inadequacy of Device Shape and/or Size 2 2
Device Handling Problem 2 2
Difficult or Delayed Separation 2 2
Activation, Positioning or Separation Problem 2 2
Degraded 2 2
Unraveled Material 2 2
Microbial Contamination of Device 2 2
Structural Problem 1 1
Off-Label Use 1 1
Disconnection 1 1
Loose or Intermittent Connection 1 1
Nonstandard Device 1 1
Material Too Soft/Flexible 1 1
Escape 1 1
Tear, Rip or Hole in Device Packaging 1 1

Patient Problems MDRs with this Patient Problem Events in those MDRs
No Clinical Signs, Symptoms or Conditions 131 131
No Consequences Or Impact To Patient 95 95
No Known Impact Or Consequence To Patient 59 59
Extubate 34 34
Insufficient Information 21 21
No Patient Involvement 15 15
Fall 12 12
No Code Available 10 10
No Information 9 9
Death 6 6
Skin Tears 6 6
Not Applicable 6 6
Irritability 5 5
Emotional Changes 5 5
Bruise/Contusion 4 4
Skin Erosion 4 4
Loss of consciousness 3 3
Injury 3 3
Confusion/ Disorientation 3 3
Bone Fracture(s) 3 3
Unspecified Mental, Emotional or Behavioural Problem 2 2
Laceration(s) 2 2
Choking 2 2
Anxiety 2 2
Skin Irritation 2 2
Unintended Extubation 2 2
Cardiac Arrest 1 1
Irritation 1 1
Blood Loss 1 1
Abrasion 1 1
Needle Stick/Puncture 1 1
Concussion 1 1
Numbness 1 1
Hematoma 1 1
Head Injury 1 1
Cardiopulmonary Arrest 1 1
Pain 1 1
Paresis 1 1
Unspecified Tissue Injury 1 1
Therapeutic Response, Decreased 1 1
Hemorrhage/Bleeding 1 1
Sweating 1 1
Complaint, Ill-Defined 1 1
Reinfusion 1 1
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available 1 1
Fracture, Arm 1 1
Ventilator Dependent 1 1
Damage to Ligament(s) 1 1
Device Embedded In Tissue or Plaque 1 1

Recalls
Manufacturer Recall Class Date Posted
1 DeRoyal Industries Inc II Aug-22-2022
2 DeRoyal Industries Inc II Mar-30-2020
3 DeRoyal Industries Inc II Mar-14-2014
4 J T Posey Company II Apr-09-2013
5 J T Posey Company II Sep-22-2009
6 J T Posey Company II Feb-03-2009
7 Med Tec Inc II Sep-14-2015
8 Med Tec Inc II Jan-15-2015
9 Queen Comfort Products lLC II Nov-01-2021
10 TIDI PRODUCTS II Oct-25-2019
-
-