Device culdoscope (and accessories)
Product CodeHEW
Regulation Number 884.1640
Device Class 2


Premarket Reviews
ManufacturerDecision
APPLIED MEDICAL RESOURCES
  SUBSTANTIALLY EQUIVALENT 1
APPLIED MEDICAL RESOURCES CORP.
  SUBSTANTIALLY EQUIVALENT 1
COOPER SURGICAL INC.
  SUBSTANTIALLY EQUIVALENT 1
COOPERSURGICAL, INC.
  SUBSTANTIALLY EQUIVALENT 2
J.SINGH INSTRUMENTS
  SUBSTANTIALLY EQUIVALENT 1
LSI SOLUTIONS, INC.
  SUBSTANTIALLY EQUIVALENT 1
SURGITOOLS PTY LTD.
  SUBSTANTIALLY EQUIVALENT 1

MDR Year MDR Reports MDR Events
2014 2 2
2016 9 9
2017 15 15
2018 13 13
2019 29 29
2020 35 35
2021 14 14
2022 23 23
2023 18 18
2024 5 5

Device Problems MDRs with this Device Problem Events in those MDRs
Break 30 30
Melted 19 19
Detachment of Device or Device Component 17 17
Material Separation 8 8
Entrapment of Device 7 7
Adverse Event Without Identified Device or Use Problem 7 7
Inflation Problem 6 6
Sparking 5 5
Insufficient Information 5 5
Defective Device 5 5
Material Fragmentation 5 5
Leak/Splash 5 5
Material Rupture 4 4
Thermal Decomposition of Device 3 3
Overheating of Device 3 3
Poor Quality Image 3 3
Material Twisted/Bent 3 3
Improper or Incorrect Procedure or Method 3 3
Smoking 3 3
Component Missing 3 3
Material Puncture/Hole 2 2
Use of Device Problem 2 2
Device Dislodged or Dislocated 2 2
Material Split, Cut or Torn 2 2
Therapeutic or Diagnostic Output Failure 2 2
Product Quality Problem 2 2
Device Fell 2 2
Defective Component 2 2
Excess Flow or Over-Infusion 2 2
Nonstandard Device 2 2
Loose or Intermittent Connection 2 2
Mechanics Altered 1 1
Flaked 1 1
Difficult to Insert 1 1
Malposition of Device 1 1
Material Perforation 1 1
Microbial Contamination of Device 1 1
Fluid/Blood Leak 1 1
Mechanical Problem 1 1
Crack 1 1
Display or Visual Feedback Problem 1 1
Output Problem 1 1
Mechanical Jam 1 1
Unintended Movement 1 1
Arcing 1 1
Fitting Problem 1 1
Material Deformation 1 1
Material Integrity Problem 1 1
Fire 1 1
Material Disintegration 1 1
Burst Container or Vessel 1 1
Gas/Air Leak 1 1
No Display/Image 1 1
Disassembly 1 1
Appropriate Term/Code Not Available 1 1
Increase in Pressure 1 1
Contamination /Decontamination Problem 1 1

Patient Problems MDRs with this Patient Problem Events in those MDRs
No Known Impact Or Consequence To Patient 43 43
No Clinical Signs, Symptoms or Conditions 36 36
Insufficient Information 15 15
Laceration(s) 12 12
No Patient Involvement 11 11
Foreign Body In Patient 10 10
No Consequences Or Impact To Patient 9 9
Uterine Perforation 6 6
Hemorrhage/Bleeding 4 4
Device Embedded In Tissue or Plaque 4 4
No Information 3 3
Unspecified Infection 3 3
Burn(s) 2 2
Perforation 2 2
Bowel Perforation 1 1
Discomfort 1 1
Injury 1 1
Burn, Thermal 1 1
Adhesion(s) 1 1
Perforation of Vessels 1 1
Menstrual Irregularities 1 1
Pain 1 1
No Code Available 1 1
Unspecified Tissue Injury 1 1
Vascular Dissection 1 1

Recalls
Manufacturer Recall Class Date Posted
1 CooperSurgical, Inc. II May-26-2021
2 CooperSurgical, Inc. II Jul-15-2019
3 CooperSurgical, Inc. II Oct-11-2018
-
-