Device
computer, diagnostic, pre-programmed, single-function
Product Code
DXG
Regulation Number
870.1435
Device Class
2
Premarket Reviews
Manufacturer
Decision
APPLIED PHYSIOLOGY PTY LTD.
SUBSTANTIALLY EQUIVALENT
1
BOMED INC
SUBSTANTIALLY EQUIVALENT
1
CARDIOX CORP.
SUBSTANTIALLY EQUIVALENT
1
CHEETAH MEDICAL INC.
SUBSTANTIALLY EQUIVALENT
1
DIRECTED SYSTEMS LTD
SUBSTANTIALLY EQUIVALENT
2
EDWARDS LIFESCIENCES
SUBSTANTIALLY EQUIVALENT
1
EDWARDS LIFESCIENCES, LLC
SUBSTANTIALLY EQUIVALENT
1
EDWARDS LIFESCIENCES, LLC.
SUBSTANTIALLY EQUIVALENT
4
GE HEALTHCARE FINLAND OY
SUBSTANTIALLY EQUIVALENT
1
ICU MEDICAL
SUBSTANTIALLY EQUIVALENT
1
LIDCO LTD
SUBSTANTIALLY EQUIVALENT
2
LIDCO LTD.
SUBSTANTIALLY EQUIVALENT
2
PULSION MEDICAL SYSTEMS AG
SUBSTANTIALLY EQUIVALENT
1
PULSION MEDICAL SYSTEMS SE
SUBSTANTIALLY EQUIVALENT
3
PULSION MEDICAL SYSTEMS, INC.
SUBSTANTIALLY EQUIVALENT
1
RETIA MEDICAL, LLC
SUBSTANTIALLY EQUIVALENT
1
TRANSONIC SYSTEMS, INC.
SUBSTANTIALLY EQUIVALENT
4
MDR Year
MDR Reports
MDR Events
2014
44
44
2015
34
34
2016
67
67
2017
62
62
2018
83
83
2019
81
81
2020
49
49
2021
29
29
2022
44
44
2023
8
8
2024
5
5
Device Problems
MDRs with this Device Problem
Events in those MDRs
Incorrect Measurement
233
233
Incorrect, Inadequate or Imprecise Result or Readings
231
231
Smoking
33
33
Fire
14
14
Sparking
12
12
Device Displays Incorrect Message
11
11
Display or Visual Feedback Problem
11
11
Break
10
10
Output Problem
10
10
Temperature Problem
8
8
High Test Results
8
8
Operating System Becomes Nonfunctional
8
8
Device Operates Differently Than Expected
7
7
Electrical Power Problem
6
6
Therapeutic or Diagnostic Output Failure
6
6
No Display/Image
6
6
Overheating of Device
6
6
Device Alarm System
6
6
Thermal Decomposition of Device
6
6
Inaccurate Information
6
6
Unable to Obtain Readings
5
5
Failure to Power Up
4
4
Device Emits Odor
4
4
Leak/Splash
4
4
Improper Device Output
4
4
Melted
3
3
High Readings
3
3
Application Program Freezes, Becomes Nonfunctional
3
3
Failure to Zero
3
3
Loss of Power
3
3
Material Fragmentation
2
2
Low Test Results
2
2
Defective Device
2
2
Output below Specifications
2
2
Electrical /Electronic Property Problem
2
2
Intermittent Communication Failure
2
2
Adverse Event Without Identified Device or Use Problem
2
2
Appropriate Term/Code Not Available
2
2
Use of Device Problem
2
2
Data Problem
2
2
Material Integrity Problem
2
2
Ambient Temperature Problem
2
2
Low Readings
2
2
Improper or Incorrect Procedure or Method
2
2
Battery Problem
2
2
Energy Output Problem
1
1
Inappropriate/Inadequate Shock/Stimulation
1
1
Electro-Static Discharge
1
1
Failure to Advance
1
1
Power Problem
1
1
Material Discolored
1
1
Inflation Problem
1
1
Excessive Cooling
1
1
Material Twisted/Bent
1
1
Component Missing
1
1
No Audible Alarm
1
1
Failure to Calibrate
1
1
Increase in Pressure
1
1
Circuit Failure
1
1
Inappropriate or Unexpected Reset
1
1
Device Difficult to Program or Calibrate
1
1
Connection Problem
1
1
Noise, Audible
1
1
Crack
1
1
Low Audible Alarm
1
1
Imprecision
1
1
Device Damaged Prior to Use
1
1
Moisture Damage
1
1
Loose or Intermittent Connection
1
1
Erratic or Intermittent Display
1
1
Decrease in Pressure
1
1
Image Display Error/Artifact
1
1
Unintended Movement
1
1
Pressure Problem
1
1
Misassembly by Users
1
1
Positioning Failure
1
1
Application Network Problem
1
1
Unexpected Shutdown
1
1
Device Issue
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Consequences Or Impact To Patient
267
267
No Known Impact Or Consequence To Patient
210
210
No Clinical Signs, Symptoms or Conditions
83
83
No Patient Involvement
56
56
Burn(s)
4
4
Death
2
2
No Code Available
2
2
Superficial (First Degree) Burn
2
2
Insufficient Information
1
1
No Information
1
2
Alteration In Body Temperature
1
1
Injury
1
1
Reaction
1
1
High Blood Pressure/ Hypertension
1
1
Necrosis
1
1
Swelling
1
1
Blurred Vision
1
1
Cardiac Arrest
1
1
Cardiopulmonary Arrest
1
1
Stroke/CVA
1
1
Recalls
Manufacturer
Recall Class
Date Posted
1
Edwards Lifesciences, Llc
II
Feb-02-2012
2
Edwards Lifesciences, Llc
II
Oct-28-2010
3
GETINGE US SALES LLC
II
Jul-25-2019
4
Hospira Inc
II
Nov-09-2009
5
ICU Medical, Inc.
II
Jan-14-2021
6
ICU Medical, Inc.
II
May-07-2020
7
Lidco Ltd
II
Dec-30-2020
8
Transonic Systems Inc
II
Apr-18-2013
-
-