Device
system, peritoneal, automatic delivery
Regulation Description
Peritoneal dialysis system and accessories.
Product Code
FKX
Regulation Number
876.5630
Device Class
2
Premarket Reviews
Manufacturer
Decision
ABBOTT
SUBSTANTIALLY EQUIVALENT
6
BAXTER HEALTHCARE CORP.
SUBSTANTIALLY EQUIVALENT
6
C.R. BARD, INC.
SUBSTANTIALLY EQUIVALENT
2
DEKA RESEARCH & DEVELOPMENT CORP.
SUBSTANTIALLY EQUIVALENT
1
FRESENIUS
SUBSTANTIALLY EQUIVALENT
2
Lifemed of California
SUBSTANTIALLY EQUIVALENT
1
ORGANON-TEKNIKA
SUBSTANTIALLY EQUIVALENT
1
PHYSIO-CONTROL, INC.
SUBSTANTIALLY EQUIVALENT
1
Device Problems
Fluid leak
388
Device displays error message
224
Overfill
149
Leak
80
Air leak
75
Disconnection
62
Improper or incorrect procedure or method
57
Component falling
50
No Information
46
No code available
41
Hole in material
29
Device operates differently than expected
21
Detachment of device component
18
Use of Device Issue
14
Break
10
No Known Device Problem
10
Contamination during use
7
Ultrafiltration
6
Excess flow or overinfusion
6
Cut in material
5
Detachment of device or device component
4
Dislodged or dislocated
4
Collapse
4
Component(s), broken
4
Material puncture
4
Failure to prime
4
Human-Device Interface Issue
4
Infusion or flow issue
4
Material separation
3
Alarm, audible
3
Device Difficult to Setup or Prepare
3
Volume accuracy issue
3
Loose or intermittent connection
3
Occlusion within device
2
Connection issue
2
Manufacturing or shipping issue associated with device
2
Grounding malfunction
2
Difficult to insert
2
Scratched material
2
Material rupture
2
Misconnection
2
Sticking
2
Nonstandard device or device component
2
Shipping damage or problem
2
Crack
2
Incorrect display
2
No flow
2
Smoking
2
Defective item
2
Blocked connection
2
Other (for use when an appropriate device code cannot be identified)
2
Unknown (for use when the device problem is not known)
2
Inaccurate delivery
2
Out-of-box failure
2
Difficult to remove
2
Unsealed device packaging
1
Inappropriate prompts
1
Use of Incorrect Control Settings
1
Failure to cycle
1
Fracture
1
Material twisted
1
Split
1
Improper flow or infusion
1
Packaging issue
1
Not Applicable
1
Filling problem
1
Mechanical issue
1
Not audible alarm
1
Slippage of device or device component
1
Suction issue
1
Reuse
1
Failure to Adhere or Bond
1
Defective component
1
Battery issue
1
Unintended collision
1
Material discolored
1
Kinked
1
Device alarm system issue
1
Burn of device or device component
1
Insufficient flow or underinfusion
1
Failure to spike
1
Perivalvular leak
1
Failure to reset
1
Misassembled
1
Total Device Problems
1418
Recalls
2007
2008
2009
2010
2011
2012
2013
Class I
0
0
0
1
0
0
0
Class II
0
1
0
1
2
2
1
Class III
0
0
0
0
0
0
0
Recalls
Manufacturer
Recall Class
Date Posted
1
Baxter Healthcare Renal Div
II
Aug-02-2012
2
Baxter Healthcare Renal Div
II
Jul-06-2011
3
Baxter Healthcare Renal Div
II
May-03-2011
4
Baxter Healthcare Renal Div
I
Mar-01-2010
5
Baxter Healthcare Renal Div
II
Mar-07-2008
6
Fresenius Medical Care Holdings, Inc.
II
Feb-11-2013
7
Fresenius Medical Care Holdings, Inc.
II
Apr-24-2012
8
Fresenius Medical Care Holdings, Inc.
II
Oct-20-2010
-
-