|
Device | EDWARDS SAPIEN TRANSCATHETER HEART VALVE AND ACCESSORIES |
Generic Name | Aortic valve, prosthesis, percutaneously delivered |
Applicant | EDWARDS LIFESCIENCES LLC. One Edwards Way Irvine, CA 92614 |
PMA Number | P110021 |
Date Received | 05/02/2011 |
Decision Date | 10/19/2012 |
Withdrawal Date
|
03/18/2019 |
Product Code |
NPT |
Docket Number | 12M-1088 |
Notice Date | 11/07/2012 |
Advisory Committee |
Cardiovascular |
Expedited Review Granted? | Yes |
Combination Product | No |
Recalls | CDRH Recalls |
Approval Order Statement APPROVAL FOR EDWARDS SAPIEN¿ TRANSCATHETER HEART VALVE MODEL 9000TFX, SIZES 23MM AND 26MM, AND TRANSAPICAL AND TRANSFEMORAL ACCESSORIES LISTED ABOVE. THIS DEVICE IS INDICATED FOR THE FOLLOWING:TRANSAPICAL - THE EDWARDS SAPIEN TRANSCATHETER HEART VALVE, MODEL 9000TFX, SIZES 23 MM AND 26 MM, IS INDICATED FOR TRANSAPICAL DELIVERY IN PATIENTS WITH SEVERE SYMPTOMATIC CALCIFIED NATIVE AORTIC VALVESTENOSIS WITHOUT SEVERE AORTIC INSUFFICIENCY AND WITH EJECTION FRACTION >= 20% WHO HAVE BEEN EXAMINED BY A HEART TEAM INCLUDING AN EXPERIENCED CARDIAC SURGEON AND A CARDIOLOGIST AND FOUND TO BE OPERATIVE CANDIDATES FOR AORTIC VALVE REPLACEMENT BUT WHO HAVE A SOCIETY OF THORACIC SURGEONS OPERATIVE RISK SCORE >= 8% OR ARE JUDGED BY THE HEART TEAM TO BE AT A >=15% RISK OF MORTALITY FOR SURGICAL AORTIC VALVE REPLACEMENT. THE ASCENDRA BALLOON CATHETER IS INDICATED FOR THE TRANSAPICAL DELIVERY OF THE EDWARDS SAPIEN TRANSCATHETER HEART VALVE. TRANSFEMORALTHE EDWARDS SAPIEN TRANSCATHETER HEART VALVE, MODEL 9000TFX, SIZES 23 MM AND 26 MM, ISINDICATED FOR TRANSFEMORAL DELIVERY IN PATIENTS WITH SEVERE SYMPTOMATIC CALCIFIED NATIVE AORTIC VALVESTENOSIS WITHOUT SEVERE AORTIC INSUFFICIENCY AND WITH EJECTION FRACTION >20% WHO HAVE BEENEXAMINED BY A HEART TEAM INCLUDING AN EXPERIENCED CARDIAC SURGEON AND A CARDIOLOGIST AND FOUND TOEITHER BE: 1) INOPERABLE AND IN WHOM EXISTING CO-MORBIDITIES WOULD NOT PRECLUDE THE EXPECTEDBENEFIT FROM CORRECTION OF THE AORTIC STENOSIS; OR 2) BE OPERATIVE CANDIDATES FOR AORTIC VALVE REPLACEMENT BUT WHO HAVE A SOCIETY OF THORACIC SURGEONS PREDICTED OPERATIVE RISK SCORE > 8% OR ARE JUDGED BY THE HEART TEAM TO BE AT A >15% RISK OF MORTALITY FOR SURGICAL AORTIC VALVE REPLACEMENT.THE RETROFLEX 3 DELIVERY SYSTEM IS INDICATED FOR THE TRANSFEMORAL DELIVERY OF THE EDWARDSSAPIEN TRANSCATHETER HEART VALVE. |
Approval Order | Approval Order |
Summary | Summary of Safety and Effectiveness |
Labeling | Labeling
|
Post-Approval Study | Show Report Schedule and Study Progress |
Supplements: |
S015 S016 S017 S042 S044 S009 S010 S013 S001 S002 S003 S004 S049 S050 S051 S033 S040 S026 S027 S028 S029 S030 S031 S034 S035 S036 S045 S046 S005 S006 S007 S008 S052 S053 S014 S041 S047 S048 S018 S019 S020 S021 S022 S037 S038 S039 S023 S024 S025 S055 S056 |