• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Recognized Consensus Standards

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | Registration & Listing | Adverse Events | Recalls | PMA | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

New Search Back To Search Results
Recognition List Number: 020 Publication Date: 09/09/2008 

Part B: SUPPLEMENTARY INFORMATION

Recognition Number 8-63: ISO 5832-11:1994, Implants for surgery -- Metallic materials -- Part 11: Wrought titanium 6-aluminium 7-niobium alloy. (Materials)

Date of Standard: 1994. 
Address of Standards Organization:
  International Organization for Standardization (ISO)*
  1, Rue de Varembe
  Case Postale 56
  CH 1211 Geneva 20, 0
  SWITZERLAND
CDRH Offices and Divisions Associated with Recognized Standards:
(1)OFFICE OF DEVICE EVALUATION (ODE)
(2)OFFICE OF DEVICE EVALUATION (ODE)
Devices Affected:
Implantable Medical Devices
Processes Affected:
510(K), PMA, IDE, PDP, HDE, Design Controls
Type of Standard:
 International, Horizontal
Extent of Recognition:
This standard includes requirements for chemical composition, metallurgical characteristics, and mechanical properties in various conditions. Although this material has a long history of successful use for implants, the standard has no specific requirements regarding biologic response. Refer to the appropriate biocompatibility standards for specific biocompatibility requirements. Additional information must be provided to document that the design of the product will provide adequate mechanical properties for the particular application. Depending on the device application, additional material property data (such as fatigue life, wear and abrasion resistance, pitting or crevice corrosion resistance, and magnetic susceptibility) may be required beyond what is addressed by this standard.
Related CFR Citations and Product Codes:
Regulation
Number
Device Name Device
Class
Product
Code
§872.3640 Implant, Endosseous, Root-Form Class 2 DZE
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.3645 Implant, Subperiosteal Class 2 ELE
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.3890 Splint, Endodontic Stabilizing Class 2 ELS
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.3940 Joint, Temporomandibular, Implant Class 3 LZD
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.3950 Glenoid Fossa Prosthesis Class 3 MPI
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.3960 Mandibular Condyle Prosthesis Class 3 MPL
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.4600 Lock, Wire, And Ligature, Intraoral Class 2 DYX
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.4760 External Mandibular Fixator And/Or Distractor Class 2 MQN
§872.4760 Implant, Transmandibular Class 2 MDL
§872.4760 Plate, Bone Class 2 JEY
 
Regulation
Number
Device Name Device
Class
Product
Code
§872.4880 Screw, Fixation, Intraosseous Class 2 DZL
 
No Product Code information listed for §872.4XXX, Metallic components
 
No Product Code information listed for §888.3XXX, Metallic components of all implantables
 
Relevant Guidance:
There is no relevant guidance developed at this time.
FDA Technical Contacts:
  John Goode (Orthopaedics)
  FDA/CDRH/ODE/DGRND
  9200 CORPORATE BLVD, HFZ-410
  ROCKVILLE MD 20850
  240/276-3676
  Email: JOHN.GOODE@FDA.HHS.GOV
  Michael J. Ryan (Dental)
  FDA/CDRH/ODE
  10903 New Hampshire Avenue Building 66, Room 1615
  Silver Spring MD 20993
  301/796-6283
  Email: michael.ryan@fda.hhs.gov
* In the United States, copies of this standard can be obtained from:
  American National Standards Institute (ANSI)*
  25 West 43rd Street
  4th Floor
  New York, NY 10036
-
-