• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Recognized Consensus Standards

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | Registration & Listing | Adverse Events | Recalls | PMA | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

New Search Back To Search Results
Recognition List Number: 022 Publication Date: 09/08/2009 

Part B: SUPPLEMENTARY INFORMATION

Recognition Number 11-213: ASTM F1223-08, Standard Test Method for Determination of Total Knee Replacement Constraint. (Orthopaedics)

Date of Standard: 2008. 
Address of Standards Organization:
  ASTM International (ASTM)
  100 Barr Harbor Drive
  West Conshohocken, PA 19428-2959
 
CDRH Office and Division Associated with Recognized Standards:
OFFICE OF DEVICE EVALUATION (ODE)
Devices Affected:
Total knee replacement (TKR) prostheses
Processes Affected:
510(k), HDE, IDE, PMA, PDP,Design Controls
Type of Standard:
 National, Vertical, Test Methods
Extent of Recognition:
Complete standard

This test method covers procedures to establish a database of total knee replacement (TKR) motion characteristics. It provides a means by which the TKR constraint may be quantified according to motion delineated by the articulation design.

Additional information must be provided to document that the design of the product will provide adequate mechanical properties for the particular application. In applications subjected to wear or articulation, additional data may be needed to document resistance to wear and abrasion.
Related CFR Citations and Product Codes:
Regulation
Number
Device Name Device
Class
Product
Code
Unclassified Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Polymer/Metal/Polymer Class 3 LXY
Unclassified Prosthesis, Knee, Patello/Femorotibial, Unconstrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer Class 3 MBD
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3480 Metal Cemented Constrained Femorotibial Knee Prosthesis Class 3 KRN
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3490 Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented Class 2 KTX
§888.3490 Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented Class 2 KMB
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3500 Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite Class 2 KYK
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3510 Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer Class 2 KRO
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3520 Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Class 2 HSX
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3530 Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer Class 2 HRY
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3550 Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal Class 3 KRP
§888.3550 Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer Class 2 KRQ
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3560 Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer Class 2 MBV
§888.3560 Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer Class 2 JWH
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3565 Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer Class 2 MBH
 
Relevant Guidance:
Class II Special Controls Guidance Document: Knee Joint Patellofemorotibial and Femorotibial Metal/Polymer Porous-Coated Uncemented Prostheses; Guidance for Industry and FDA, January 16, 2003
FDA Technical Contact:
  John Goode
  FDA/CDRH/ODE
  10903 New Hampshire Avenue Building 66, Room 1510
  Silver Spring MD 20993
  301/796-6407
  Email: john.goode@fda.hhs.gov
-
-