Part B: SUPPLEMENTARY INFORMATION
ANSI / RESNA , . () |
| Addresses of Standards Organizations: |
| American National Standards Institute (ANSI) |
| 25 West 43rd Street |
| 4th Floor |
| New York, NY 10036 |
| |
| Rehabilitation Engineering and Assistive Technology Society of North America (RESNA) |
| 1700 N. Moore Street |
| Suite 1540 |
| Arlington, VA 22209-1903 |
| |
|
| CDRH Office and Division Associated with Recognized Standards: |
| OFFICE OF DEVICE EVALUATION (ODE) | | |
|
|
| Devices Affected: |
|
| Processes Affected: |
|
| Type of Standard: |
| Test Methods, National, Vertical |
| Related CFR Citations and Product Codes: |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3800 |
Vehicle, Motorized 3-Wheeled |
Class 2 |
INI |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3850 |
Wheelchair, Mechanical |
Class 1 |
IOR |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3860 |
Wheelchair, Powered |
Class 2 |
ITI |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3880 |
Wheelchair, Special Grade |
Class 2 |
IQC |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3890 |
Wheelchair, Stair Climbing |
Class 3 |
IMK |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3900 |
Wheelchair, Standup |
Class 2 |
IPL |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3930 |
Elevator, Wheelchair, Portable |
Class 2 |
ING |
| |
|
| FDA Technical Contact: |
| Laurence Coyne |
| FDA/CDRH/ODE |
| 10903 New Hampshire Avenue Building 66, Room 1526 |
| Silver Spring MD 20993 |
| 301/796-5650 |
| Email: laurence.coyne@fda.hhs.gov |
|
|