Recognition Number 16-180: ANSI / RESNA WC-2:2009, American National Standard for Wheelchairs - Volume 2: Additional Requirements for Wheelchairs (including Scooters) with Electrical Systems Section 14: Power and control systems for electrically powered wheelchairs ¿ Requirements and test methods. (Physical Medicine)
Date of Standard: 2009. |
| Addresses of Standards Organizations: |
| American National Standards Institute (ANSI) |
| 25 West 43rd Street |
| 4th Floor |
| New York, NY 10036 |
| |
| Rehabilitation Engineering and Assistive Technology Society of North America (RESNA) |
| 1700 N. Moore Street |
| Suite 1540 |
| Arlington, VA 22209-1903 |
| |
|
| CDRH Office and Division Associated with Recognized Standards: |
| OFFICE OF DEVICE EVALUATION (ODE) | | |
|
|
| Devices Affected: |
| Powered Wheelchairs and Motorized 3-Wheeled Vehicles (Scooters) |
|
| Processes Affected: |
| 510(K), IDE, PMA, PDP, Design Controls |
|
| Type of Standard: |
| Test Methods, National, Vertical |
| Extent of Recognition: |
Complete Standard.
Standard specifies the requirements for the power and control systems of electrically powered wheelchairs, including battery chargers, and associated test methods.
If the specified maximum capacity of the device is greater than 100 kg, a custom-designed test dummy should be used to complete this test. The design of the test dummy should follow the guidelines provided in RESNA WC-1:2009 American National Standard for Wheelchairs - Volume 1: Requirements and Test Methods for Wheelchairs (including Scooters) Section 11 Test dummies.
Manufacturers should disclose the results of the testing in the product labeling.
Manufacturers should also document that the ground leakage current for the battery charger does not exceed 100 u Amp ANSI/AAMI ES60601-1:2005, Medical Electrical Equipment - Part 1: General)requirements for basic safety and essential performance. |
|
| Related CFR Citations and Product Codes: |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3800 |
Vehicle, Motorized 3-Wheeled |
Class 2 |
INI |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3860 |
Wheelchair, Powered |
Class 2 |
ITI |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3880 |
Wheelchair, Special Grade |
Class 2 |
IQC |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3890 |
Wheelchair, Stair Climbing |
Class 3 |
IMK |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3900 |
Wheelchair, Standup |
Class 2 |
IPL |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §890.3930 |
Elevator, Wheelchair, Portable |
Class 2 |
ING |
| |
|
| Relevant Guidance: |
| There is no relevant guidance developed at this time. |
|
| FDA Technical Contact: |
| Laurence Coyne |
| FDA/CDRH/ODE |
| 10903 New Hampshire Avenue Building 66, Room 1526 |
| Silver Spring MD 20993 |
| 301/796-5650 |
| Email: laurence.coyne@fda.hhs.gov |
|
|