Recognition List Number: 029 Publication Date: 08/20/2012
Part B: SUPPLEMENTARY INFORMATION
Recognition Number 7-218: CLSI M45-A2, Methods for Antimicrobial Dilution and Disk Susceptibility Testing of Infrequently Isolated or Fastidious Bacteria; Approved Guideline - Second Edition. (InVitro Diagnostics)
Date of Standard: 2006. |
| Address of Standards Organization: |
| Clinical Laboratory Standards Institute (CLSI) |
| 950 West Valley Road |
| Suite 2500 |
| Wayne, PA 19087 |
| |
|
| CDRH Office and Division Associated with Recognized Standards: |
| OFFICE OF IN VITRO DIAGNOSTICS AND RADIOLOGICAL HEALTH (OIR) | | DIVISION OF MICROBIOLOGY (DMD) |
|
|
| Devices Affected: |
| Antimicrobial Susceptibility minimum inhibitory concentration (MIC) and disk diffusion devices. |
|
| Processes Affected: |
|
| Type of Standard: |
| Horizontal, National |
| Extent of Recognition: |
| Partial: CDRH recognizes the methods used for MIC and disk diffusion test, however we can not recognize interpretive criteria when different from that in CDER approved drug labels. |
|
| Related CFR Citations and Product Codes: |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §866.1620 |
Discs, Elution |
Class 2 |
LTX |
| §866.1620 |
Susceptibility Test Discs, Antimicrobial |
Class 2 |
JTN |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §866.1640 |
Manual Antimicrobial Susceptibility Test Systems |
Class 2 |
JWY |
| §866.1640 |
Panels, Test, Susceptibility, Antimicrobial |
Class 2 |
LTT |
| §866.1640 |
Solution, Antimicrobial |
Class 2 |
LOP |
| §866.1640 |
Susceptibility Test Cards, Antimicrobial |
Class 2 |
LTW |
| §866.1640 |
Susceptibility Test Powders, Antimicrobial |
Class 2 |
JTT |
| §866.1640 |
Susceptibility Test Powders, Antimycobacterial |
Class 2 |
MJA |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §866.1645 |
System, Test, Automated, Antimicrobial Susceptibility, Short Incubation |
Class 2 |
LON |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §866.1700 |
Culture Media, Antifungal, Susceptibility Test |
Class 2 |
MJE |
| §866.1700 |
Culture Media, Antimicrobial Susceptibility Test |
Class 2 |
LKA |
| §866.1700 |
Culture Media, Antimicrobial Susceptibility Test, Excluding Mueller Hinton Agar |
Class 2 |
JSO |
| §866.1700 |
Culture Media, Antimicrobial Susceptibility Test, Mueller Hinton Agar/Broth |
Class 2 |
JTZ |
| §866.1700 |
Culture Media, Antimycobacteria, Susceptibility Test |
Class 2 |
MJD |
| |
|
| Relevant Guidance: |
| There is no relevant guidance developed at this time. |
|
| FDA Technical Contacts: |
| Alexandra Wong |
| FDA/CDRH/OIVD |
| 10993 New Hampshire Avenue Building 66, Room 5502 |
| Silver Spring MD 20993 |
| 301/796-6210 |
| Email: alexandra.wong@fda.hhs.gov |
|
| Ribhi Shawar, Ph.D. |
| FDA/CDRH/OIVD |
| 10903 New Hampshire Avenue Building 66, Room 5513 |
| Silver Spring MD 20993 |
| 301/796-6698 |
| Email: ribhi.shawar@fda.hhs.gov |
|
|
|
|