Recognition List Number: 030 Publication Date: 01/15/2013 

Part B: SUPPLEMENTARY INFORMATION

Recognition Number 11-250: ISO 14242-3 First edition 2009-03-15, Implants for surgery - Wear of total hip-joint prostheses - Part 3: Loading and displacement parameters for orbital bearing type wear testing machines and corresponding envrionmental conditions for test. (Orthopaedics)

Date of Standard: 2009. 
Address of Standards Organization:
  International Organization for Standardization (ISO)*
  1, Rue de Varembe
  Case Postale 56
  CH 1211 Geneva 20, 0
  SWITZERLAND
CDRH Office and Division Associated with Recognized Standards:
OFFICE OF DEVICE EVALUATION (ODE)
DIVISION OF SURGICAL DEVICES (DSD)
Devices Affected:
Total hip protheses
Processes Affected:
510(k), HDE, IDE, PMA, PDP, Design Controls
Type of Standard:
 Vertical, International, Test Methods
Extent of Recognition:
Complete standard

This standard specifies relative angular movemenet between articulating components, the pattern of the applied force, speed and duration of testing, sample configuration and test environment to be used for the orbital bearing type wear testing of total hip joint prostheses.

Additional information must be provided to document that the design of the product will provide adequate mechanical properties for the particular application.
Related CFR Citations and Product Codes:
Regulation
Number
Device Name Device
Class
Product
Code
Unclassified Prosthesis, Hip, Semi-Constrained, Ceramic-On-Metal Articulation Class 3 OVO
Unclassified Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic, Cemented Class 3 LPF
Unclassified Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic/Metal, Cemented Or Uncemented Class 3 MRA
Unclassified Prosthesis, Hip, Semi-Constrained, Metal/Metal, Resurfacing Class 3 NXT
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3300 Prosthesis, Hip, Constrained, Metal Class 3 KXD
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3320 Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component) Class 3 JDL
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3330 Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component) Class 3 KWA
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3340 Prosthesis, Hip, Semi-Constrained, Composite/Metal Class 2 KMC
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3350 Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented Class 2 OQH
§888.3350 Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented Class 2 JDI
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3353 Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented Class 2 OQI
§888.3353 Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish Class 2 MAY
§888.3353 Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented Class 2 LZO
§888.3353 Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate Class 2 MEH
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3358 Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented Class 2 OQG
§888.3358 Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented Class 2 LPH
§888.3358 Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous Class 2 MBL
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3360 Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented Class 2 LWJ
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3390 Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented Class 2 KWY
 
Regulation
Number
Device Name Device
Class
Product
Code
§888.3410 Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer Class 3 KXB
§888.3410 Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented Class 3 OCG
 
Relevant Guidance:
There is no relevant guidance developed at this time.
FDA Technical Contact:
  John Goode
  FDA/CDRH/ODE
  10903 New Hampshire Avenue Building 66, Room 1510
  Silver Spring MD 20993
  301/796-6407
  Email: john.goode@fda.hhs.gov
* In the United States, copies of this standard can be obtained from:
  American National Standards Institute (ANSI)*
  25 West 43rd Street
  4th Floor
  New York, NY 10036
-
-