Recognition List Number: 030 Publication Date: 01/15/2013
Part B: SUPPLEMENTARY INFORMATION
Recognition Number 11-248: ISO 14242-1 Second edition 2012-01-15, Implants for surgery -- Wear of total hip-joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test. (Orthopaedics)
Date of Standard: 2012. |
| Address of Standards Organization: |
| International Organization for Standardization (ISO)* |
| 1, Rue de Varembe |
| Case Postale 56 |
| CH 1211 Geneva 20, 0 |
|
SWITZERLAND
|
|
| CDRH Office and Division Associated with Recognized Standards: |
| OFFICE OF DEVICE EVALUATION (ODE) | | DIVISION OF SURGICAL DEVICES (DSD) |
|
|
| Devices Affected: |
|
| Processes Affected: |
| 510(k), HDE, IDE, PMA, PDP, Design Controls |
|
| Type of Standard: |
| Vertical, International, Test Methods |
| Extent of Recognition: |
Complete standard
This standard specifies the relative angular movement between articulating components, the pattern of the applied force, the speed and duration of testing, the sample configuration and the test environment to be used for the wear testing of total hip-joint prostheses.
Additional information must be provided to document that the design of the product will provide adequate mechanical properties for the particular application. |
|
| Related CFR Citations and Product Codes: |
Regulation Number |
Device Name |
Device Class |
Product Code |
| Unclassified |
Prosthesis, Hip, Semi-Constrained, Ceramic-On-Metal Articulation |
Class 3 |
OVO |
| Unclassified |
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic, Cemented |
Class 3 |
LPF |
| Unclassified |
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic/Metal, Cemented Or Uncemented |
Class 3 |
MRA |
| Unclassified |
Prosthesis, Hip, Semi-Constrained, Metal/Metal, Resurfacing |
Class 3 |
NXT |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3300 |
Prosthesis, Hip, Constrained, Metal |
Class 3 |
KXD |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3310 |
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer |
Class 2 |
KWZ |
| §888.3310 |
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive |
Class 2 |
PBI |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3320 |
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component) |
Class 3 |
JDL |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3330 |
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component) |
Class 3 |
KWA |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3340 |
Prosthesis, Hip, Semi-Constrained, Composite/Metal |
Class 2 |
KMC |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3350 |
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented |
Class 2 |
OQH |
| §888.3350 |
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented |
Class 2 |
JDI |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3353 |
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented |
Class 2 |
OQI |
| §888.3353 |
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish |
Class 2 |
MAY |
| §888.3353 |
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented |
Class 2 |
LZO |
| §888.3353 |
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate |
Class 2 |
MEH |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3358 |
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented |
Class 2 |
OQG |
| §888.3358 |
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented |
Class 2 |
LPH |
| §888.3358 |
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous |
Class 2 |
MBL |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3360 |
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented |
Class 2 |
LWJ |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3390 |
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented |
Class 2 |
KWY |
| |
Regulation Number |
Device Name |
Device Class |
Product Code |
| §888.3410 |
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer |
Class 3 |
KXB |
| §888.3410 |
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented |
Class 3 |
OCG |
| |
|
| Relevant Guidance: |
| There is no relevant guidance developed at this time. |
|
| FDA Technical Contact: |
| John Goode |
| FDA/CDRH/ODE |
| 10903 New Hampshire Avenue Building 66, Room 1510 |
| Silver Spring MD 20993 |
| 301/796-6407 |
| Email: john.goode@fda.hhs.gov |
|
|
|
| * In the United States, copies of this standard can be obtained from: |
| American National Standards Institute (ANSI)* |
| 25 West 43rd Street |
| 4th Floor |
| New York, NY 10036 |
|
|