• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Recognized Consensus Standards

  • Print
  • Share
  • E-mail
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC

New Search Back To Search Results
Recognition List Number: 034 FR Publication Date: 01/30/2014 

Part B: Supplementary Information

Recognition Number 8-187: ISO 13779-1 Second edition 2008-10-01, implants for surgery - hydroxyapatite - part 1: ceramic hydroxyapatite. (Materials)

Date of Standard: 2008. 
Address of Standards Development Organization:
 International Organization for Standardization (ISO)*
  1, Rue de Varembe
  Case Postale 56
  CH 1211 Geneva 20, 0
CDRH Office and Division associated with recognized standards:
Devices Affected:
Orthopedic implants including various components of the following joint replacement devices: Hip, Knee, and Shoulder Protheses.
Processes Affected:
510(k), PMA, IDE, PDP, HDE, Design Controls
Type of Standard:
 International, Vertical
Extent of Recognition:
Complete standard
Related CFR Citations and Product Codes:
Device Name Device
§888.3358 Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented Class 2 LPH
§888.3358 Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous Class 2 MBL
§888.3535 Prosthesis, Knee, Femorotibial, Semi-Constrained, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer Class 2 NJD
§888.3565 Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer Class 2 MBH
§888.3670 Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented Class 2 MBF
Relevant Guidance:
Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone Cement, April 28, 1994

510(k) Information Needed for Hydroxyapatite Coated Orthopedic Implants, March 10, 1995 (revised 2/20/97)

Guidance for Industry and FDA Staff - Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Implant Abutments, May 12, 2004
FDA Technical Contact:
 Hany Demian
  10903 New Hampshire Avenue WO66 RM5502
  Silver Spring MD 20993
  email: hany.demian@fda.hhs.gov
* in the United States, copies of this standard can be obtained from:
  American National Standards Institute (ANSI)*
  25 West 43rd Street
  4th Floor
  New York, NY 10036