Enforcement Report - Week of August 8, 2012

  • Print
  • Share
  • E-mail
-

Event Detail

Event ID 62504
Product Type Devices
Status Ongoing
Recalling Firm Stryker Instruments Div. of Stryker Corporation
City Portage
State MI
Country US
Voluntary/Mandated Voluntary: Firm Initiated
Recall Initiation Date 2012-07-17
Initial Firm Notification of
Consignee or Public
Two or more of the following: Email, Fax, Letter, Press Release, Telephone, Visit
Distribution Pattern Worldwide Distribution - US Nationwide and the countries of England, France, Netherlands, and Switzerland.

Product Detail

Product Description Code Info Classification Reason for Recall Product Quantity Recall Number
RF Cannula, 100 mm,Curved 5 MM, 20 G, REF 0406-630-115 RX only, Disposable ( 10/pk) Product Usage: The Stryker RF Cannulae, in combination with the Stryker RF Generator/Multi- Gen and electrodes, are intended for coagulation of soft tissue in orthopedic, arthroscopic, spinal, and neurosurgical applications. REF 0406-630-115, lot 1000035056 Class II Stryker has received 6 complaints that the 5mm needle was placed in 10 mm package and 10 mm needle was placed in the 5 mm package. If the clinician does not recognize that the active tip on the cannula is 10 mm instead of 5mm and the cannula is used in a cervical procedure there is a potential for a thermal skin lesion due to a larger lesion creation. If the 10 mm active tip cannula, as opposed to the 5mm active tip, is placed perpendicular to the target on a very thin patient, there is a potential for the patient to be exposed to skin burn. 210 Z-2134-2012
RF Cannula, 100 mm,Curved 10 MM, 20 G, REF 0406-630-125 RX only, Disposable ( 10/pk) Product Usage: The Stryker RF Cannulae, in combination with the Stryker RF Generator/Multi- Gen and electrodes, are intended for coagulation of soft tissue in orthopedic, arthroscopic, spinal, and neurosurgical applications. REF 0406-630-125, lot 1000037535 Class II Stryker has received 6 complaints that the 5mm needle was placed in 10 mm package and 10 mm needle was placed in the 5 mm package. If the clinician does not recognize that the active tip on the cannula is 10 mm instead of 5mm and the cannula is used in a cervical procedure there is a potential for a thermal skin lesion due to a larger lesion creation. If the 10 mm active tip cannula, as opposed to the 5mm active tip, is placed perpendicular to the target on a very thin patient, there is a potential for the patient to be exposed to skin burn. 226 Z-2135-2012
-
-