Event ID 63174
Product Type Devices
Status Ongoing
Recalling Firm Accutron Inc
City Phoenix
State AZ
Country US
Voluntary/Mandated Voluntary: Firm Initiated
Recall Initiation Date 2012-04-29
Initial Firm Notification of
Consignee or Public
Letter
Distribution Pattern US Nationwide Distribution

Product Detail

Product Description Code Info Classification Reason for Recall Product Quantity Recall Number
Newport Portable Package, Model #50000, Serial # 13591, 13592, 13604, 13606, 13614, 13662, 13663, 13664, 13726, 13731, 13733, 13736, 13737, 13738, 13740, 13768, 13770, 13771, 13772, 13784, 13787. Product Usage: Portable Analgesia Gas Machine. Lot # 73656, 74139, 75209, 74689, 75515, 74858. Class I Accutron is recalling the Flowmeter (Analgesia Gas Machine) because when it flows Nitrous Gas without Oxygen gas being turned on, it functions in an incorrect manner. 220 units total Z-0020-2013
CM Flowmeter Pkg H, Model #36700, Serial # 13749 Product Usage: Conscious Sedation Unit Analgesia Gas Machine. Lot # 75285 Class I Accutron is recalling the Flowmeter (Analgesia Gas Machine) because when it flows Nitrous Gas without Oxygen gas being turned on, it functions in an incorrect manner. 220 units total Z-0019-2013
Ultra PC% Cabinet Mount Package G, Model #36600, Serial # 13593, 13594, 13595, 13596, 13597, 13598, 13599, 13600, 13602, 13605, 13610, 13611, 13612, 13615, 13616, 13617, 13621, 13622, 13624, 13625, 13627, 13628, 13633, 13634, 13635, 13636, 13637, 13638, 13639, 13640, 13642, 13643, 13644, 13647, 13650, 13669, 13675, 13673, 13678, 13679, 13680, 13683, 13685, 13687, 13691, 13693, 13694, 13695, 13696, 13697, 13701, 13702, 13705, 13706, 13709, 13710, 13711, 13724, 13725, 13728, 13729, 13735, 13739, 13743, 13746, 13750, 13751, 13753, 13754, 13755, 13756, 13760, 13762, 13766, 13774, 13775, 13777, 13781, 13782, 13783, 13785, 13786, 13788, 13792, 13794, 13796, 13799, 13800, 13803, 13804, 13809, 13810, 28298, 28299, 28304, 28305, 28306, 28307, Ultra PC% Cabinet Mount Pkg I, Model #36800, Serial # 13601, 13603, 13607, 13608, 13609, 13613, 13618, 13620, 13623, 13626, 13629, 13630, 13631, 13632, 13641, 13645, 13646, 13648, 13649, 13651, 13652, 13653, 13654, 13655, 13656, 13657, 13658, 13659, 13660, 13661, 13665, 13666, 13667, 13668, 13671, 13672, 13674, 13676, 13677, 13684, 13688, 13689, 13698, 13700, 13707, 13723, 13727, 13730, 13732, 13734, 13741, 13742, 13757, 13758, 13759, 13761, 13762, 13763, 13764, 13765, 13767, 13769, 13789, 13790, 13791, 13795, 13797, 13801, 13802, 13806, 13808, 28300, 28302, 28303, Ultra PC% Cabinet Mount Pkg G, Model#36600-NS, Serial# 13805, 13807, 13811, 13812. Ultra PC% Cabinet Mount Pkg H, Model#36800-NS, Serial# 13744, 13745,13752, 13773, 13774, 13778, 13779, 13780 Product Usage: Conscious Sedation Unit Analgesia Gas Machine. Model #36600, Lot # 73778, 73740, 73851, 73920, 74475, 74035, 74012, 74219, 74118, 74471, 75583, 74372, 75049, 74745, 75049, 75283, 75616, 75299, 74926, 75767, 75344, 75311, 74513. Model #36800, Lot# 73739, 73852, 74011, 73921, 74470, 74032, 74011, 73969, 74139, 74125, 74204, 74220, 74143, 74617, 74573, 74746, 75584, 75449, 74927, 75617, 74568 Model#36600-NS, Lot#75328. Model#36800-NS, Lot#75286. Class I Accutron is recalling the Flowmeter (Analgesia Gas Machine) because when it flows Nitrous Gas without Oxygen gas being turned on, it functions in an incorrect manner. 220 units total Z-0018-2013
Flow Meter, CM Assembly, Model #27025, Serial # 13686, 13690, 13712, 13793. Flowmeter, CM Assembly, Model#31970, Serial#13692. Product Usage: Conscious Sedation Unit Analgesia Gas Machine. Model#27025: Lot # 73971, 74929. Model#31970: Lot#74142. Class I Accutron is recalling the Flowmeter (Analgesia Gas Machine) because when it flows Nitrous Gas without Oxygen gas being turned on, it functions in an incorrect manner. 220 units total Z-0017-2013
-
-