• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Scientific Publications by FDA Staff

  • Print
  • Share
  • E-mail
-

Search Publications



Fields



Centers











Starting Date


Ending Date


Order by

Entry Details

J Nanotechnol Eng Med 2014 Apr 15;4(4):040902

Enhanced heat transfer and thermal dose using magnetic nanoparticles during HIFU thermal ablation--an in-vitro study.

Dibaji SAR, Al-Rjoub MF, Myers MR, Banerjee RK

Abstract

Avoiding collateral damage to healthy tissues during the high intensity focused ultrasound (HIFU) ablation of malignant tumors is one of the major challenges for effective thermal therapy. Such collateral damage can originate out of the need for using higher acoustic powers to treat deep seated or highly vascularized tumors. The objective of this study is to assess the utility of using magnetic nanoparticles (mNPs) during HIFU procedures to locally enhance heating at low powers, thereby reducing the likelihood of collateral thermal damage and undesired destruction due to cavitation. Tissue phantoms with 0% (control), 1% and 3% mNPs concentrations by volume were fabricated. Each tissue phantom was embedded with four thermocouples (TCs) and sonicated using transducer acoustic powers of 5.15¿W, 9.17¿W, and 14.26¿W. The temperature profiles during the heating and cooling periods were recorded for each embedded TC. The measured transient temperature profiles were used for thermal-dose calculations. The increase in the concentration of mNPs in the tissue phantoms, from 0% to 3%, resulted in the rise in the peak temperatures for all the TCs for each acoustic power. The thermal dose also increased with the rise in the concentration of mNPs in the tissue phantoms. For the highest applied acoustic power (14.26¿W), the peak temperature at TC 1 (T1) in tissue phantoms with 1% and 3% mNPs concentrations increased (with respect to tissue phantom with 0% (control) mNPs concentration) by 1.59× and 2.09×, respectively. For an acoustic power of 14.26¿W, the time required to achieve cellular necrosis as defined by a 240 equivalent min thermal dose was approximately 75 s in the absence of mNPs, 14 s for the 1% concentration, and 8 s for the 3% concentration. Magnetic nanoparticles have the potential to significantly reduce the time for HIFU thermal-ablation procedures. They can also decrease the likelihood of collateral damage by the propagating beam in HIFU procedures by reducing the intensity required to achieve cellular necrosis.


Category: Journal Article
DOI: 10.1115/1.4027340
Includes FDA Authors from Scientific Area(s): Medical Devices
Entry Created: 2016-02-19
Feedback
-
-