• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Recognized Consensus Standards

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

New Search Back To Search Results
Part B: Supplementary Information Sheet (SIS)
FR Recognition List Number 050 Date of Recognition 09/17/2018 
FR Recognition Number 14-514
Standard
ISO 11737-1 Third edition 2018-01
Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on product
U.S. Identical Adoption
ANSI AAMI ISO 11737-1:2018
Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microrganisms on products
Scope/Abstract
ISO 11737-1:2018 specifies requirements and provides guidance on the enumeration and microbial characterization of the population of viable microorganisms on or in a health care product, component, raw material or package.

NOTE 1 The nature and extent of microbial characterization is dependent on the intended use of bioburden data.

NOTE 2 See Annex A for guidance on Clauses 1 to 9.

ISO 11737-1:2018 does not apply to the enumeration or identification of viral, prion or protozoan contaminants. This includes the removal and detection of the causative agents of spongiform encephalopathies, such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease.

NOTE 3 Guidance on inactivating viruses and prions can be found in ISO 22442‑3, ICH Q5A(R1) and ISO 13022.

ISO 11737-1:2018 does not apply to the microbiological monitoring of the environment in which health care products are manufactured.

Extent of Recognition
Complete standard
Rationale for Recognition
This standard is relevant to medical devices and is recognized on its scientific and technical merit and/or because it supports existing regulatory policies.
Relevant FDA Guidance and/or Supportive Publications
ISO 11737-2 Second edition 2009-11-15 Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process.
FDA Technical Contact
 Elizabeth Gonzalez
  FDA/OMPT/CDRH/ODE/DRGUD/RNDB/
  301-796-6826
  Elizabeth.Gonzalez@fda.hhs.gov
Standards Development Organization
ISO International Organization for Standardization https://www.iso.org/
FDA Specialty Task Group (STG)
Sterility
-
-