Post-Approval Studies (PAS) Database

  • Print
  • Share
  • E-mail
-

The FDA has the authority to require sponsors to perform a post-approval study (or studies) at the time of approval of a premarket approval (PMA), humanitarian device exemption (HDE), or product development protocol (PDP) application. Post-approval studies can provide patients, health care professionals, the device industry, the FDA and other stakeholders information on the continued safety and effectiveness (or continued probable benefit, in the case of an HDE) of approved medical devices. This database allows you to search Post-Approval Study information by applicant or device information.

Learn more...


           

Jewel P-WCD Post-Approval Study


Suggest Enhancement / Report Issue | export reports to excelExport to Excel
General
Study Status Ongoing
Application Number /
Requirement Number
P230022 / PAS001
Date Original Protocol Accepted 08/20/2025
Date Current Protocol Accepted 11/19/2025
Study Name Jewel P-WCD Post-Approval Study
Device Name Jewel Patch Wearable Cardioverter Defibrillator (P-WCD) ("Jewel"), Jewel P-WCD Firmware, Device Accessories Skin Preparation Kit, Placement Accessory, Device Removal Kit, Optional Software Accessories ES Mobile Application, ES Cloud, ES Report Generator, ES Clinical Portal
Clinical Trial Number(s) NCT05201495 
General Study Protocol Parameters
Study Design Prospective Cohort Study
Data Source Sponsor Registry
Comparison Group Historical Control
Analysis Type Descriptive
Study Population Transit.Adolescent B(as adults): 18 yrs < 22 yrs, Adult: At least 22 yrs
Detailed Study Protocol Parameters
Study Objectives This will be a prospective cohort study to demonstrate the continued safety and clinical effectiveness of the Jewel P-WCD. The study will also demonstrate the generalizability of the arrhythmia detection algorithm which was developed using techniques of artificial intelligence and machine learning (AI/ML). The study is also described by the sponsor as being an observational registry study.

All Jewel P-WCDs will be collected by the Sponsor following the end of the prescription period or device use, per commercial process. Devices which cannot be retrieved per commercial process will be considered lost to follow up.
Study Population All patients who are prescribed and receive a Jewel P-WCD device.
Sample Size Number of subjects: 6,330 to capture 100 shockable VT/VF events.
Assumptions for sample size estimation: It is assumed that the event rate will be similar to the KESTRA ACE PAS (Kestra Medical Technologies) which was 1.58%.
Number of sites: N/A
Sites location: N/A
Key Study Endpoints Safety Endpoints
Primary: The primary safety endpoint is to observe an inappropriate shock rate of no more than 2.0 inappropriate shocks per 100 patient-months using a one sided upper 90% confidence interval. Only first inappropriate shocks during analyzable wear time will contribute to the analysis of this endpoint. The appropriateness of shocks will be determined by the patient’s medical team.
Secondary: The secondary endpoints (report only) for this study are to observe: the proportion of subjects experiencing skin related Adverse Device Effects classified as MDR reportable; and, the number of subjects who deferred a shock and percentage of events successfully deferred.

Effectiveness Endpoints
Primary: The primary effectiveness endpoint is to demonstrate an overall detection rate greater than 87%, using a 90% one-sided lower confidence limit.
Secondary: N/A
Follow-up Visits and Length of Follow-up this is a registry and has no investigational device or intervention. Data will be analyzed after the completion of the prescribed wear period.
Interim or Final Data Summary
Interim Results N/A
Actual Number of Patients Enrolled 5
Actual Number of Sites Enrolled N/A
Patient Follow-up Rate N/A
Final Safety Findings N/A


Jewel P-WCD Post-Approval Study Reporting Schedule

Reporting Schedule
Report
Date Due
FDA Receipt
Date
Applicant's Reporting Status
6 month report 02/20/2026 02/19/2026 On Time
1 year report 08/20/2026 08/18/2026 On Time
18 month report 02/19/2027    
2 year report 08/20/2027    
3 year report 08/18/2028    
4 year report 08/20/2029    
final report 10/19/2029    