| General |
| Study Status |
Ongoing |
Application Number / Requirement Number |
P240020 / PAS001 |
| Date Original Protocol Accepted |
09/05/2025
|
| Date Current Protocol Accepted |
09/05/2025
|
| Study Name |
Continued Long-Term Follow-up Study
|
| Device Name |
TOUCH® CMC 1 Prosthesis
|
| Clinical Trial Number(s) |
NCT01954433
|
| General Study Protocol Parameters |
| Study Design |
Prospective Cohort Study
|
| Data Source |
New Data Collection
|
| Comparison Group |
No Control
|
| Analysis Type |
Descriptive
|
| Study Population |
Adult: At least 22 yrs
|
| Detailed Study Protocol Parameters |
| Study Objectives |
Study Design and Objective(s) A descriptive prospective, single-center, single-arm study design. To evaluate the 5-year long-term safety and effectiveness of the TOUCH CMC 1 Prosthesis.
|
| Study Population |
Study Population Enrollment of the patients included in the original PMA cohort (Touch Cohort Swiss study), who are evaluable for the long term 5 year follow up, which includes all 103 remaining patients, from the original 149 patients.
Supplemental analysis will evaluate: - Retrospective PMCF 5-Year Study: N=74 patients (82 devices) - Published Falaise et al. 2025: N=57 patients (61 devices)
|
| Sample Size |
103
|
| Key Study Endpoints |
Study Endpoints Primary endpoints: A Year 5 composite clinical success (CCS) primary endpoint will be employed. To be a success, a subject must meet all of the following criteria: • Improvement of pain: A clinically meaningful improvement in pain defined as a decrease in the pain score of = 30% on a 10-point scale. • Maintenance or improvement in function: defined by key pinch strength which is = 85% of the subject’s pre-operative key pinch strength. • Safety: success is defined as freedom from: o Subsequent secondary surgical interventions (SSI) (i.e., reoperation, revision, removal of any study component, or supplemental fixations) on the study carpometacarpal joint, or Serious, device- or procedure-related adverse events. Secondary endpoints: • Pain evolution (% change), as measured by either Numerical Rating Scale (NRS) or Visual Analog Scale (VAS) on a 10-point scale • Key pinch strength (kg) evolution • Kapandji index • Patient satisfaction via brief Michigan Hand Outcomes Questionnaire (bMHQ) • Return to work time • Radiographic success – investigators will make best efforts to obtain 5 years post-operative radiographs for all enrolled subjects: absence of device migration, osteolysis, radiolucencies or fracture Individual components of the CCS including need for revision surgery and serious, device-related adverse events¿
|
| Follow-up Visits and Length of Follow-up |
5 years
|