The FDA has the authority to require sponsors to perform a post-approval study (or studies) at the time of approval of a premarket approval (PMA), humanitarian device exemption (HDE), or product development protocol (PDP) application. Post-approval studies can provide patients, health care professionals, the device industry, the FDA and other stakeholders information on the continued safety and effectiveness (or continued probable benefit, in the case of an HDE) of approved medical devices. This database allows you to search Post-Approval Study information by applicant or device information.

Learn more...


           

MAGiC-CHD Post-Approval Study


Suggest Enhancement / Report Issue | export reports to excelExport to Excel
General
Study Status Study Pending
Application Number /
Requirement Number
P240014 / PAS001
Date Original Protocol Accepted 07/31/2026
Date Current Protocol Accepted 07/31/2026
Study Name MAGiC-CHD Post-Approval Study
Device Name MAGiC Ablation Catheter
Clinical Trial Number(s) NCT06019845 
General Study Protocol Parameters
Study Design Prospective Cohort Study
Data Source New Data Collection
Comparison Group No Control
Analysis Type Descriptive
Study Population Adult: At least 22 yrs
Detailed Study Protocol Parameters
Study Objectives The MAGiC-CHD Post-Approval Study is a prospective, nonrandomized, multi-center, single-arm study to confirm the effectiveness and safety of the MAGiC Ablation Catheter for the treatment of supraventricular tachycardia (SVT) in adult patients with congenital heart disease (CHD) and limited vascular access or difficult access to the target cardiac chamber.
The objective of MAGiC-CHD is to collect device-related Major Adverse Events, and acute and chronic success rates with MAGiC in subjects with CHD being treated for a cardiac arrhythmia.
Study Population Adult patients with congenital heart disease (CHD) and limited vascular access or difficult access to the target cardiac chamber.
Sample Size Number of subjects: 40
Assumptions for sample size estimation:
Number of sites: 10
Sites location: TBA
Key Study Endpoints Safety Endpoints
Safety will be assessed by the rate of device- or procedure-related serious adverse events through 7 days post procedure.
Effectiveness Endpoints
The primary endpoint is: 1. to estimate the rate of acute procedural success, defined as the percentage of patients with successful resolution of the treated index arrhythmia at the end of the procedure; and 2. to estimate the rate of chronic success through 6 months post-procedure, defined as the percentage of patients free
from documented sustained recurrence of the treated index arrhythmia.
Additional endpoints will be collected and reported:
¿ Rate of serious adverse events related to the MAGiC Ablation Catheter
¿ Acute procedural success and chronic success by type of target arrhythmia and by specific congenital defect and surgical repair.
¿ Arrhythmia or procedure related hospitalization and major adverse events through 6 months follow-up.
¿ All serious adverse events for severity, relatedness and outcome.
¿ Procedure Details
o Procedure time (groin puncture to removal of all sheaths)
o Total fluoroscopy time and dose
¿ Estimating the change in patient quality of life and arrhythmia burden.
Follow-up Visits and Length of Follow-up Follow-up clinical data will be collected at discharge, 7 days, 1 month, and 6 months post-procedure.


MAGiC-CHD Post-Approval Study Reporting Schedule

Reporting Schedule
Report
Date Due
FDA Receipt
Date
Applicant's Reporting Status
6 month report 07/06/2026 07/08/2026 Overdue/Received
1 year report 01/05/2027    
18 month report 07/06/2027    
2 year report 01/05/2028    
30 month report 07/05/2028    
3 year report 01/04/2029    
42 month report 07/05/2029    
4 year report 01/04/2030    