| General |
| Study Status |
Study Pending |
Application Number / Requirement Number |
P230030 S012/ PAS001 |
| Date Original Protocol Accepted |
08/06/2026
|
| Date Current Protocol Accepted |
08/06/2026
|
| Study Name |
FAR-AHEAD Study
|
| Device Name |
FARAPULSE™ Pulsed Field Ablation System (FARAWAVE™ Pulsed Field Ablation Catheter, FARAWAVE™ NAV Pulsed Field Ablation Catheter, FARAPOINT™ Pulsed Field Ablation Catheter, FARASTAR™ Catheter Connection Cable, FARASTAR™ Pulsed Field Ablation Generator, FARASTAR™ Recording System Module, FARASTAR™ Mapping System Module, FARASTAR™ Stimulation Module Cable, FARASTAR™ EGM Cable, FARASTAR™ Stimulation Module Male Cable, FARASTAR™ Stimulation Module Female Cable, FARASTAR™ Stimulation Module Y-Cable Long, FARASTAR™ Stimulation Module Y-Cable Short, FARASTAR™ Recording System Module Catheter Pin Cable, FARASTAR™ Recording System Module ECG Trunk Cable, FARASTAR™ Recording System Module ECG Output Module (AAMI/IEC), FARASTAR™ Recording System Module EGM Input Module, FARASTAR™ SNAP CABLE R/L – (AAMI/IEC), FARASTAR™ SNAP CABLE V SET – (AAMI), FARASTAR™ SNAP CABLE C SET – (IEC), FARASTAR™ Recording System Module ECG Output to Rhythmia HDx™ ECG Input Cable, FARASTAR™ Recording System Module EGM Ou
|
| Clinical Trial Number(s) |
NCT05443594
|
| General Study Protocol Parameters |
| Study Design |
Comprehensive/Linked/RegistryBased Surveillance
|
| Data Source |
New Data Collection
|
| Comparison Group |
Objective Performance Criterion
|
| Analysis Type |
Descriptive
|
| Study Population |
Adult: At least 22 yrs
|
| Detailed Study Protocol Parameters |
| Study Objectives |
To obtain real world clinical data on the safety and effectiveness of the FARAPOINT catheter for CTI ablation as an adjunctive treatment of drug-refractory, symptomatic PsAF (episode duration <1 year) in support of the following objectives: 4. Estimating the primary safety adverse event rate at 30 days following PsAF ablation procedure using the FARAWAVE™ Pulsed Field Ablation Catheter and the FARAPOINT™ Pulsed Field Ablation Catheter. 5. Estimating the rate of chronic RCA stenosis (>= 50% obstruction) related to CTI ablation with the FARAPOINT™ Pulsed Field Ablation Catheter. 6. Estimating the rate of durable CTI conduction block following concomitant CTI ablation with the FARAPOINT™ Pulsed Field Ablation Catheter.
|
| Sample Size |
Number of subjects: 265 Assumptions for sample size estimation: Ensure a very high probability (99%-99.5%) to detect at least one primary safety event (primary study objective #1), assuming an event rate of 2% based on results from ADVANTAGE AF Phase 2 FARAPOINT treatment subjects Number of sites: 10 Sites location: TBA
|
| Key Study Endpoints |
Data collection will include the following: - Medical history and demographics - Acute procedural details - 30-day evaluation of primary safety - 6- and 12-month rhythm monitoring for recurrence - At least 60 PsAF subjects will undergo a baseline and 12-month post-procedure CTA to assess RCA stenosis - Re-mapping data for patients undergoing redo during the 12-month follow-up to evaluate the durability of the CTI lesion - 3-year post-discharge composite rate for acute coronary syndrome, new ischemic electrocardiogram (ECG) changes consistent with inferior ischemia requiring treatment, hemodynamically significant coronary artery spasm requiring intracoronary nitroglycerin and/or causing ST-segment elevation, urgent coronary angiography with an RCA culprit finding, and cardiac death - 36 – month freedom from AF/AFL/AT recurrence from medical chart review
|
| Follow-up Visits and Length of Follow-up |
Patients in FAR-AHEAD will be enrolled and followed for 36 months post-ablation.
|