This page lists ASCA-accredited testing laboratories and their respective scopes of accreditation.

Notes:

  • Testing laboratories who wish to participate in ASCA should demonstrate that they have been accredited by an ASCA-recognized accreditation body to the currently FDA-recognized versions of the standards and test methods included in ASCA. Please check the Recognized Consensus Standards database for the currently recognized versions.
  • Some FDA-recognized consensus standards included in ASCA have an identical U.S. adoption (for example, IEC 60601-2-47, ANSI/AAMI/IEC 60601-2-47). If a testing laboratory has an international (e.g., IEC, ISO) version of a standard in their scope of ASCA Accreditation, any identical US adoption associated with the FDA Recognition number is also considered included in the testing laboratory's scope. For example, if IEC 60601-2-47 with FDA Recognition number 3-155 is listed in a testing laboratory's scope of ASCA Accreditation, testing to the associated ANSI AAMI IEC version is also acceptable even if it is not explicitly listed in the testing lab's scope.
  • Some FDA-recognized international consensus standards (e.g., IEC, ISO) included in ASCA are recognized specifically with U.S. national differences applied (e.g., IEC 60601-1, IEC 61010-1). When U.S. national differences are applied to the international versions, they are considered equivalent to the corresponding U.S. adoptions of those standards (e.g., ANSI AAMI ES60601-1, ANSI UL 61010-1). For testing laboratories listed below with such standards in their scope, both the US adoptions and the international versions of the standards are considered as part of their scope of ASCA Accreditation.
  • As of January 3,2024, Bay Area Compliance Lab has been withdrawn from the ASCA program.
  • Learn more...


    Arrow buttons can be used to sort the table by each column heading.

    Super Search Devices@FDA
    510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
    CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
     

    Test Lab: UL-CCIC COMPANY LIMITED GUANGZHOU BRANCH [TL-75]
    Accreditation Status: Accreditation Granted - Date: 06/24/2021
    Accreditation Body Organization Name: International Acccreditation Service, Inc. (IAS)
    Test Lab Primary Contact: Pamela Gwynn, Pamela.K.Gwynn@ul.com, ELECTRONIC BUILDING, PARAGE ELECTRONIC INDUSTRIAL PARK, NO.8, NANYUN ER ROAD, GUANGZHOU SCIENCE PARK GUANGZHOU CN 510670
     
    Scope of ASCA Accreditation Return to list of Testing Labs
    Status
    Status
    Date
    Sort by Standard Designation Number and Date [0 - 9]
    Sort by Standard Designation Number and Date [9 - 0]
    Category
    Sort by Standard Designation Number and Date [0 - 9]
    Sort by Standard Designation Number and Date [9 - 0]
    Biocompatibility
    Test
    Method
    Sort by Standard Designation Number and Date [0 - 9]
    Sort by Standard Designation Number and Date [9 - 0]
    Recognition
    Number
    Sort by Standard Designation Number and Date [0 - 9]
    Sort by Standard Designation Number and Date [9 - 0]
    Standards
    Development
    Organization
    Standard Designation
    Number and Date
    Title
    Exclusions
    Accreditation Granted 06/24/2021 Basic safety and essential performance   1-139 ISO 80601-2-61 Second edition 2017-12 (Corrected version 2018-02) Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
    Accreditation Granted 06/24/2021 Basic safety and essential performance   1-140 ISO 80601-2-55 Second edition 2018-02 Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors
    Accreditation Granted 06/24/2021 Basic safety and essential performance   12-293 IEC 60601-2-37 Edition 2.1 2015 Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment
    Accreditation Granted 06/24/2021 Basic safety and essential performance   17-16 IEC 60601-2-10 Edition 2.1 2016-04 Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators
    Accreditation Granted 06/24/2021 Basic safety and essential performance   19-34 IEC 61010-1 Edition 3.1 2017-01 CONSOLIDATED VERSION Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements [Including: Corrigendum 1 (2019)] - Note: This standard is recognized with relevant US national differences applied, see reference #1 in Relevant FDA Guidance and/or Supportive Publication section
    Accreditation Granted 06/24/2021 Basic safety and essential performance   19-38 IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
    Accreditation Granted 06/24/2021 Basic safety and essential performance   19-39 IEC 60601-1-12 Edition 1.1 2020-07 CONSOLIDATED VERSION Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment
    Accreditation Granted 10/10/2022 Basic safety and essential performance   19-46 ANSI, AAMI ES60601-1:2005/(R)2012 & A1:2012, C1:2009/(R)2012 & A2:2010/(R)2012 (Cons. Text) [Incl. AMD2:2021] Medical electrical equipment - Part 1: General requirements for basic safety and essential performance (IEC 60601-1:2005, MOD) [Including Amendment 2 (2021)]
    Accreditation Granted 10/10/2022 Basic safety and essential performance   19-47 AAMI, ANSI HA60601-1-11:2015 [Including AMD1:2021] Medical Electrical Equipment -- Part 1-11: General requirements for basic safety and essential performance -- Collateral Standard: Requirements for medical electrical equipment and medical electrical equipment and medical electrical systems used in the home healthcare environment (IEC 60601-1-11:2015 MOD) [Including Amendment1 (2021)]
    Accreditation Granted 06/24/2021 Basic safety and essential performance   3-105 IEC 60601-2-25 Edition 2.0 2011-10 Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs
    Accreditation Granted 06/24/2021 Basic safety and essential performance   3-115 IEC 60601-2-34 Edition 3.0 2011-05 Medical electrical equipment - Part 2-34: Particular requirements for the basic safety, including essential performance, of invasive blood pressure monitoring equipment
    Accreditation Granted 06/24/2021 Basic safety and essential performance   3-123 IEC 80601-2-30: Edition 2.0 2018-03 Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers
    Accreditation Granted 06/24/2021 Basic safety and essential performance   3-126 IEC 60601-2-27 Edition 3.0 2011-03 Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment [Including: Corrigendum 1 (2012)]
    Accreditation Granted 06/24/2021 Basic safety and essential performance   3-155 IEC 60601-2-47 Edition 2.0 2012-02 Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performanceof ambulatory electrocardiographic systems
    Accreditation Granted 06/24/2021 Basic safety and essential performance   5-131 IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems
    Accreditation Granted 06/24/2021 Basic safety and essential performance   5-132 IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
    Accreditation Granted 06/24/2021 Basic safety and essential performance   6-421 ISO 80601-2-56 Second edition 2017-03 [Including AMD1:2018] Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement. [Including: Amendment 1 (2018)].
     
    Scope History
    Action Type
    ASCA Status
    Effective
    Start Date
    Sort by Effective Date [0 - 9]
    Sort by Effective Date and Date [9 - 0]
    Biocompatibility
    Test Method
    Sort by Effective Date [0 - 9]
    Sort by Effective Date and Date [9 - 0]
    Recognition
    Number
    Sort by Recognition Number [0 - 9]
    Sort by Recognition Number [9 - 0]
    Designation Number
    Exclusions
    Transition Inactive 12/17/2023 19-14
    60601-1-11 Edition 2.0 2015-01
    Transition Inactive 12/17/2023 19-15
    60601-1-12 Edition 1.0 2014-06
    Transition Inactive 12/17/2023 19-16
    HA60601-1-11:2015
    Transition Inactive 12/17/2023 19-4
    ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text)
    Transition Inactive 12/17/2023 5-76
    60601-1-8 Edition 2.1 2012-11
    Transition Inactive 12/17/2023 5-89
    60601-1-6 Edition 3.1 2013-10
    -
    -