Part B: Supplementary Information Sheet (SIS)
FR Recognition List Number 044 Date of Entry 07/26/2016 
FR Recognition Number 2-119
Standard
ASTM F813-07 (Reapproved 2012)
Standard Practice for Direct Contact Cell Culture Evaluation of Materials for Medical Devices
Scope/Abstract
1.1 This practice covers a reference method of direct contact cell culture testing which may be used in evaluating the cytotoxic potential of materials for use in the construction of medical materials and devices.

1.2 This practice may be used either directly to evaluate materials or as a reference against which other cytotoxicity test methods may be compared.

1.3 This is one of a series of reference test methods for the assessment of cytotoxic potential, employing different techniques.

1.4 Assessment of cytotoxicity is one of several tests employed in determining the biological response to a material, as recommended in Practice F748.

1.5 The L-929 cell line was chosen because it has a significant history of use in assays of this type. This is not intended to imply that its use is preferred; only that the L-929 is a well-characterized, readily available, established cell line that has demonstrated reproducible results in several laboratories.

1.6 Since the test sample is not removed at the time of microscopic evaluation and underlying cells may be affected by the specific gravity of the test sample, this practice is limited to evaluation of cells outside the perimeter of the overlying test sample.
Extent of Recognition
Complete standard
Rationale for Recognition
This standard is relevant to medical devices and is recognized on its scientific and technical merit and/or because it supports existing regulatory policies.
Transition Period
FDA recognition of ASTM F813-07 (Reapproved 2012) [Rec# 2-119] will be superseded by recognition of ASTM F813-20 [Rec# 2-277]. FDA will accept declarations of conformity, in support of premarket submissions, to [Rec# 2-119] until December 18, 2022. After this transition period, declarations of conformity to [Rec# 2-119] will not be accepted
Public Law, CFR Citation(s) and Procode(s)*
21 CFR 58 Good Laboratory Practice for Nonclinical Laboratory Studies
Relevant FDA Guidance and/or Supportive Publications*
Use of International Standard ISO 10993-1, Biological evaluation of medical devices--Part 1: Evaluation and testing within a risk management process. Guidance for Industry and Food and Drug Administration Staff. Issued on June 16, 2016.

Appropriate Use of Voluntary Consensus Standards in Premarket Submissions for Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued September 2018.
FDA Technical Contacts
 Simona Bancos
  FDA/OC/CDRH/OPEQ/OHTI/DHTIA/
  301-796-6860
  simona.bancos@fda.hhs.gov
 Chandramallika (Molly) Ghosh
  FDA/OC/CDRH/OPEQ/OHTV/DHTVB/
  301-796-6496
  molly.ghosh@fda.hhs.gov
Standards Development Organization
ASTM ASTM International http://www.astm.org/
FDA Specialty Task Group (STG)
Biocompatibility
*These are provided as examples and others may be applicable.
-
-