Part B: Supplementary Information Sheet (SIS)
FR Recognition List Number 040 Date of Entry 08/14/2015 
FR Recognition Number 9-98
Standard
ISO 13959 Third edition 2014-04-01
Water for haemodialysis and related therapies
Scope/Abstract
ISO 13959:2014 specifies minimum requirements for water to be used in haemodialysis and related therapies.

ISO 13959:2014 includes water to be used in the preparation of concentrates, dialysis fluids for haemodialysis, haemodiafiltration and haemofiltration, and for the reprocessing of Haemodialysers.
Extent of Recognition
Complete standard
Transition Period
FDA recognition of ISO 13959 Third edition 2014-04-01 [Rec# 9-98] will be superseded by recognition of ISO 23500-3 First edition 2019 [Rec# 9-135]. FDA will accept declarations of conformity, in support of premarket submissions, to [Rec# 9-98] until July 10, 2022. After this transition period, declarations of conformity to [Rec# 9-98] will not be accepted.
Public Law, CFR Citation(s) and Procode(s)*
Regulation Number Device Name Device Class Product Code
§876.5665 Disinfectant, Subsystem, Water Purification Class 2 NIH
§876.5665 Subsystem, Water Purification Class 2 FIP
§876.5665 System, Water Purification, General Medical Use Class 2 NHV
§876.5820 Dialysate Concentrate For Hemodialysis (Liquid Or Powder) Class 2 KPO
§876.5820 Meter, Conductivity, Induction, Remote Type Class 2 FLB
§876.5820 Set, Dialysis, Single Needle With Uni-Directional Pump Class 2 FIF
§876.5820 Set, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed Class 2 NNG
§876.5820 Solution-Test Standard-Conductivity, Dialysis Class 2 FKH
§876.5820 Strip, Dialysate Ph Indicator Class 2 MNV
§876.5820 Strip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator Class 2 NTZ
§876.5820 Subsystem, Proportioning Class 2 FKR
§876.5820 System, Dialysate Delivery, Central Multiple Patient Class 2 FKQ
§876.5820 System, Dialysate Delivery, Recirculating Class 2 FIK
§876.5820 System, Dialysate Delivery, Recirculating, Single Pass Class 2 FIJ
§876.5820 System, Dialysate Delivery, Single Pass Class 2 FIL
§876.5820 System, Dialysate Delivery, Single Patient Class 2 FKP
§876.5860 Disinfectant, Dialysate Delivery System Class 2 NII
§876.5860 System, Dialysate Delivery, Sealed Class 2 FII
Relevant FDA Guidance and/or Supportive Publications*
Guidance for the Content of Premarket Notifications for Water Purification Components and Systems for Hemodialysis, Issued May 1997.
Regulatory Status of Disinfectants Used to Process Dialysate Delivery Systems and Water Purification Systems for Hemodialysis; Guidance for Industry and FDA, Issued August 2002.
FDA Technical Contacts
 Carolyn Neuland
  FDA/OC/CDRH/OPEQ/OHTIII/DHTIIIA/
  301-796-6523
  carolyn.neuland@fda.hhs.gov
 Gema Gonzalez
  FDA/OC/CDRH/OPEQ/OHTIII/DHTIIIA/
  301-796-6519
  gema.gonzalez@fda.hhs.gov
Standards Development Organization
ISO International Organization for Standardization https://www.iso.org/
FDA Specialty Task Group (STG)
ObGyn/Gastroenterology/Urology
*These are provided as examples and others may be applicable.
-
-