Date of Entry
|
Specialty Task Group Area
|
Recognition Number
|
Extent of Recognition
|
Standards Developing Organization
|
Standard Designation Number and Date
|
Standard Title (click for recognition information)
|
| 12/21/2020 |
Anesthesiology |
1-149 |
Complete |
ISO |
7376 Third edition 2020-08 |
Anaesthetic and respiratory equipment - Laryngoscopes for tracheal intubation |
| 12/19/2022 |
Anesthesiology |
1-160 |
Complete |
ISO |
80601-2-84 First edition 2020-07 |
Medical electrical equipment - Part 2-84: Particular requirements for the basic safety and essential performance of ventilators for the emergency medical services environment |
| 12/20/2021 |
Orthopedic |
11-388 |
Complete |
ASTM |
F1717-21 |
Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
| 04/04/2016 |
Materials |
8-200 |
Complete |
ASTM |
F2003-02 (Reapproved 2015) |
Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air |
| 01/14/2019 |
Biocompatibility |
2-141 |
Complete |
ASTM |
F1984-99 (Reapproved 2018) |
Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials |
| 12/23/2016 |
Materials |
8-441 |
Complete |
ASTM |
F3109-16 |
Standard Test Method for Verification of Multi-Axis Force Measuring Platforms |
| 12/20/2021 |
Software/ Informatics |
13-120 |
Complete |
ANSI AAMI |
2700-1:2019 |
Medical Devices and Medical Systems - Essential safety requirements for equipment comprising the patient-centric integrated clinical environment (ICE) - Part 1: General requirements and conceptual model |
| 12/20/2021 |
Materials |
8-563 |
Complete |
ASTM |
F1801-20 |
Standard Practice for Corrosion Fatigue Testing of Metallic Implant Materials |
| 12/23/2019 |
General Plastic Surgery/ General Hospital |
6-437 |
Complete |
ISO |
23907-2 First edition 2019-11 |
Sharps injury protection - Requirements and test methods - Part 2: Reusable sharps containers. |
| 03/31/2006 |
Radiology |
12-137 |
Complete |
ISO |
4090 Third eidition 2001-08-15 |
Photography - Medical radiographic cassette/screens/films and hard-copy imaging films - Dimensions and specifications |
| 10/04/2010 |
Radiology |
12-215 |
Complete |
IEC |
62494-1 Edition 1.0 (2008-08) |
Medical electrical equipment - Exposure index of digital X-ray imaging systems - Part 1: Definitions and requirements for general radiography |
| 03/16/2012 |
Radiology |
12-117 |
Complete |
ISO |
15367-1 First edition 2003-09-15 |
Lasers and laser-related equipment - Test methods for determination of the shape of a laser beam wavefront - Part 1: Terminology and fundamental aspects |
| 07/09/2014 |
Sterility |
14-437 |
Complete |
ISO ASTM |
52701 First edition 2013-11-15 (R2020) |
Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing |
| 09/17/2018 |
Materials |
8-465 |
Complete |
ISO |
5832-2 Fourth edition 2018-03 |
Implants for surgery - Metallic materials - Part 2: Unalloyed titanium |
| 12/23/2024 |
Cardiovascular |
3-193 |
Complete |
ISO |
12417-1 Second edition 2024-02 |
Cardiovascular implants and extracorporeal systems - Vascular device-drug combination products - Part 1: General requirements |
| 05/26/2025 |
General Plastic Surgery/ General Hospital |
6-512 |
Complete |
IEC |
60601-2-35 Edition 2.1 2023-12 CONSOLIDATED VERSION |
Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads and mattresses and intended for heating in medical use |
| 05/25/2026 |
Dental/ ENT |
4-368 |
Complete |
ISO |
4823 Sixth edition 2025-06 |
Dentistry - Elastomeric impression and bite registration materials |
| 12/23/2016 |
Materials |
8-437 |
Complete |
ASTM |
F2082/F2082M-16 |
Standard Test Method for Determination of Transformation Temperature of Nickel-Titanium Shape Memory Alloys by Bend and Free Recovery |
| 08/21/2017 |
Tissue Engineering |
15-49 |
Complete |
ASTM |
F2027-16 |
Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products |
| 07/09/2014 |
Tissue Engineering |
15-40 |
Complete |
ASTM |
F2211-13 |
Standard Classification for Tissue Engineered Medical Products (TEMPs) |
| 12/04/2017 |
Software/ Informatics |
13-98 |
Complete |
ISO IEC |
646 Third edition 1991-12-15 (R2018) |
Information technology - ISO 7-bit coded character set for information interchange |
| INCITS ISO IEC |
646:1991 (R2018) |
Information technology - ISO 7-bit coded character set for information interchange |
| 12/23/2024 |
Sterility |
14-609 |
Complete |
AAMI |
TIR17:2024 |
Compatibility of materials subjected to sterilization |
| 05/30/2022 |
Radiology |
12-343 |
Complete |
IEC |
62127-1 Edition 2.0 2022-03 |
Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields |
| 07/09/2014 |
InVitro Diagnostics |
7-213 |
Complete |
CLSI |
GP44-A4 (Formerly H18-A4) |
Procedures for the Handling and Processing of Blood Specimens for Common Laboratory Tests; Approved Guideline-Fourth Edition |
| 12/19/2022 |
Cardiovascular |
3-183 |
Complete |
ISO |
11658 First edition 2012-05-15 |
Cardiovascular implants and extracorporeal systems - Blood/tissue contact surface modifications for extracorporeal perfusion systems |
| ANSI AAMI ISO |
11658: 2012 |
Cardiovascular implants and extracorporeal systems - Blood/tissue contact surface modifications for extracorporeal perfusion systems |
| 08/14/2015 |
General Plastic Surgery/ General Hospital |
6-185 |
Complete |
ASTM |
F881-94 (Reapproved 2022) |
Standard Specification for Silicone Elastomer Facial Implants |
| 04/04/2016 |
Materials |
8-401 |
Complete |
ASTM |
F2118-14 (Reapproved 2020) |
Standard Test Method for Constant Amplitude of Force Controlled Fatigue Testing of Acrylic Bone Cement Materials |
| 12/23/2016 |
Materials |
8-368 |
Complete |
ASTM |
F2625-10 (Reapproved 2016) |
Standard Test Method for Measurement of Enthalpy of Fusion, Percent Crystallinity, and Melting Point of Ultra-High-Molecular Weight Polyethylene by Means of Differential Scanning Calorimetry |
| 01/30/2014 |
Sterility |
14-395 |
Complete |
ISO |
14698-2 First edition 2003-09-15 |
Cleanrooms and Associated Controlled Environments - Biocontamination Control - Part 2: Evaluation and Interpretation of Biocontamination Data [Including: Technical Corrigendum 1 (2004)] |
| 01/30/2014 |
Sterility |
14-397 |
Complete |
AOAC |
6.2.04:2013 |
Official Method 955.15, Testing Disinfectants Against Staphylococcus aureus,Use-Dilution Method |
| 01/30/2014 |
Sterility |
14-398 |
Complete |
AOAC |
6.3.05:2013 |
Official Method 966.04, Sporicidal Activity of Disinfectants Method I |
| 01/30/2014 |
Sterility |
14-399 |
Complete |
AOAC |
6.3.06:2012 |
Official Method 965.12 Tuberculocidal Activity of Disinfectants |
| 01/30/2014 |
Sterility |
14-400 |
Complete |
ASTM |
F2203-13 (Reapproved 2022) |
Standard Test Method for Linear Measurement Using Precision Steel Rule |
| 05/30/2022 |
Radiology |
12-345 |
Complete |
IEC |
61223-3-7 Edition 1.0 2021-12 |
Evaluation and routine testing in medical imaging departments - Part 3-7: Acceptance and constancy tests - Imaging performance of X-ray equipment for dental cone beam computed tomography |
| 07/26/2016 |
Biocompatibility |
2-213 |
Complete |
ASTM |
F1904-14 |
Standard Practice for Testing the Biological Responses to Particles In Vivo |
| 09/17/2018 |
Materials |
8-380 |
Complete |
ASTM |
F1160-14 (Reapproved 2017)e1 |
Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate/Metallic Coatings |
| 01/14/2019 |
Cardiovascular |
3-66 |
Complete |
ASTM |
F2081-06 (Reapproved 2017) |
Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents |
| 05/25/2026 |
Anesthesiology |
1-203 |
Complete |
ISO |
10079-1 Fourth edition 2022-03 [Including AMD1:2026] |
Medical suction equipment - Part 1: Electrically powered suction equipment [Including Amendment 1 (2026)] |
| 05/26/2025 |
Software/ Informatics |
13-143 |
Complete |
AAMI |
TIR45:2023 |
Guidance on the use of AGILE practices in the development of medical device software |
| 05/25/2026 |
Dental/ ENT |
4-369 |
Complete |
ANSI ADA |
Standard No. 113-2015 |
Periodontal Curettes, Dental Scalers and Excavators |
| 05/25/2026 |
Dental/ ENT |
4-370 |
Complete |
ANSI ADA |
Standard No. 126-2015 (R2023) |
Casting Investments and Refractory Die Materials |
| 12/20/2021 |
Cardiovascular |
3-171 |
Complete |
ASTM |
F2514-21 |
Standard Guide for Finite Element Analysis (FEA) of Metallic Vascular Stents Subjected to Uniform Radial Loading |
| 12/20/2021 |
Cardiovascular |
3-172 |
Complete |
AAMI |
TIR42:2021 |
Evaluation of Particulates Associated with Vascular Medical Devices |
| 05/30/2022 |
InVitro Diagnostics |
7-312 |
Complete |
CLSI |
M39 5th Edition |
Analysis and Presentation of Cumulative Antimicrobial Susceptibility Test Data |
| 09/17/2018 |
Materials |
8-112 |
Complete |
ASTM |
F1044-05 (Reapproved 2017)e1 |
Standard Test Method for Shear Testing of Calcium Phosphate Coatings and Metallic Coatings |
| 09/17/2018 |
Materials |
8-466 |
Complete |
ASTM |
F2213-17 |
Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
| 06/07/2018 |
Radiology |
12-316 |
Complete |
IEC |
62359 Edition 2.1 2017-09 CONSOLIDATED VERSION |
Ultrasonics - Field characterization - Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields |
| 06/07/2018 |
Nanotechnology |
18-9 |
Complete |
ISO |
TR 13014 First edition 2012-05-15 |
Nanotechnologies - Guidance on physico-chemical characterization of engineered nanoscale materials for toxicologic assessment [Including CORRIGENDUM 1 (2012)]. |
| 12/23/2024 |
Anesthesiology |
1-187 |
Complete |
ISO |
80601-2-12 Third edition 2023-11 |
Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators |
| 05/26/2025 |
Radiology |
12-379 |
Complete |
IEC |
62127-2 Edition 2.0 2025-01 |
Ultrasonics -- Hydrophones -- Part 2: Calibration for ultrasonic fields up to 40 MHz |
| 01/27/2015 |
Dental/ ENT |
4-219 |
Complete |
ISO |
29022 First edition 2013-06-01 |
Dentistry - Adhesive - Notched-edge sheer bond strength test |
| 01/30/2014 |
Materials |
8-344 |
Complete |
ISO |
7153-1 Second edition 1991-04-01 |
Surgical instruments -- Metallic materials -- Part 1: Stainless steel [Including: Amendment 1 (1999)] |
| 01/30/2014 |
Sterility |
14-401 |
Complete |
ASTM |
F2217/F2217M-13 (Reapproved 2023) |
Standard Practice for Coating/Adhesive Weight Determination |
| 05/30/2022 |
Materials |
8-593 |
Complete |
ISO |
13779-6 First Edition 2015-01-15 Corrected Version 2016-09-15 |
Implants for surgery - Hydroxyapatite - Part 6: Powders |
| 09/17/2018 |
Orthopedic |
11-336 |
Complete |
ISO |
17853 Third edition 2011-03-01 |
Wear of implant materials - Polymer and metal wear particles - Isolation and characterization |
| 01/30/2014 |
Neurology |
17-12 |
Complete |
ISO |
7197 Third edition 2006-06-01 |
Neurosurgical Implants - Sterile, single-use hydrocephalus shunts and components [Including: Technical Corrigendum 1 (2007)] |
| 01/27/2015 |
Dental/ ENT |
4-136 |
Complete |
ASTM |
F2504-05 (Reapproved 2022) |
Standard Practice for Describing System Output of Implantable Middle Ear Hearing Devices |
| 01/14/2019 |
Ophthalmic |
10-114 |
Complete |
ANSI |
Z80.28-2017 |
American National Standard for Ophthalmics - Methods of Reporting Optical Aberrations of Eyes |
| 01/14/2019 |
Software/ Informatics |
13-105 |
Complete |
ANSI AAMI |
SW91:2018 |
Classification of defects in health software |
| 05/30/2022 |
Materials |
8-589 |
Complete |
ASTM |
F1925-22 |
Standard Specification for Semi-Crystalline Poly(lactide) Polymer and Copolymer Resins for Surgical Implants |
| 12/22/2025 |
Materials |
8-628 |
Complete |
ASTM |
F754-24 |
Standard Specification for Implantable Polytetrafluoroethylene (PTFE) Sheet, Tube, and Rod Shapes Fabricated from Granular Molding Powders |
| 12/22/2025 |
Materials |
8-629 |
Complete |
ASTM |
F67-24 |
Standard Specification for Unalloyed Titanium, for Surgical Implant Applications (UNS R50250, UNS R50400, UNS R50550, UNS R50700) |
| 12/20/2021 |
Dental/ ENT |
4-289 |
Complete |
ISO |
18556 Frist edition 2016-04 |
Dentistry - Intraoral spatulas |
| 12/20/2021 |
Dental/ ENT |
4-290 |
Complete |
ISO |
28158 Second edition 2018-09 |
Dentistry - Integrated dental floss and handles |
| ANSI ADA |
Standard No. 185-2020 |
Integrated Dental Floss and Handles |
| 12/19/2022 |
ObGyn/ Gastroenterology/ Urology |
9-144 |
Complete |
ISO |
20697 First edition 2018-06; Corrected 2018-09 |
Sterile drainage catheters and accessory devices for single use |
| 12/19/2022 |
Orthopedic |
11-395 |
Complete |
ASTM |
F1814-22 |
Standard Guide for Evaluating Modular Hip and Knee Joint Components |
| 12/19/2022 |
Orthopedic |
11-396 |
Complete |
ISO |
7206-13 First edition 2016-07-01 [Including AMD1:2022] |
Implants for surgery - Partial and total hip joint prostheses - Part 13: Determination of resistance to torque of head fixation of stemmed femoral components [Including AMENDMENT 1 (2022)] |
| 12/20/2021 |
Dental/ ENT |
4-292 |
Complete |
ISO |
28888 First edition 2013-10 |
Dentistry - Screening method for erosion potential of oral rinses on dental hard tissues |
| ANSI ADA |
Standard No. 151-2015 (R2020) |
Screening Method for Erosion Potential of Oral Rinses on Dental Hard Tissues |
| 08/06/2013 |
Software/ Informatics |
13-42 |
Complete |
ANSI AAMI IEC |
TIR 80001-2-2:2012 |
Application of risk management for IT Networks incorporating medical devices - Part 2-2: Guidance for the disclosure and communication of medical device security needs, risks and controls |
| IEC |
TR 80001-2-2 Edition 1.0 2012-07 |
Application of risk management for IT Networks incorporating medical devices - Part 2-2: Guidance for the disclosure and communication of medical device security needs, risks and controls |
| 01/14/2019 |
Dental/ ENT |
4-162 |
Complete |
ANSI ASA |
S3.4-2007 (Reaffirmed 2025) |
American National Standard Procedure for the Computation of Loudness of Steady Sounds |
| 12/23/2019 |
Physical Medicine |
16-220 |
Complete |
RESNA ANSI |
WC-1:2019 Section 15 |
American National Standard for Wheelchairs - Volume 1: Requirements and Test Methods for Wheelchairs (including Scooters) Section 15: Requirements for Information Disclosure, Documentation and Labeling |
| 08/14/2015 |
Radiology |
12-291 |
Complete |
IEC |
62127-2 Edition 1.2 2017-03 CONSOLIDATED VERSION |
Ultrasonics -- Hydrophones -- Part 2: Calibration for ultrasonic fields up to 40 MHz |
| 05/26/2025 |
Radiology |
12-380 |
Complete |
IEC |
60601-2-37 Edition 3.0 2024-07 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
| 06/27/2016 |
Radiology |
12-293 |
Complete |
IEC |
60601-2-37 Edition 2.1 2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
| 12/19/2022 |
Software/ Informatics |
13-124 |
Complete |
AAMI |
CR34971:2022 |
Guidance on the Application of ISO 14971 to Artificial Intelligence and Machine Learning |
| 12/19/2022 |
Software/ Informatics |
13-125 |
Complete |
ANSI AAMI UL |
2800-1-1:2022 |
Standard for Risk Concerns for Interoperable Medical Products |
| 12/20/2021 |
Sterility |
14-563 |
Complete |
ISO |
13408-6 Second edition 2021-04 |
Aseptic processing of health care products - Part 6: Isolator systems |
| 12/20/2021 |
Sterility |
14-564 |
Complete |
USP-NF |
M98910_01_01 |
<161> Medical Devices-Bacterial Endotoxin and Pyrogen Tests |
| 04/04/2016 |
General II (ES/ EMC) |
19-17 |
Complete |
IEEE ANSI |
C63.18-2014 |
American National Standard Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Electromagnetic Immunity of Medical Devices to Radiated Radio-Frequency (RF) Emissions from RF Transmitters |
| 12/04/2017 |
Software/ Informatics |
13-103 |
Complete |
IEC |
TR 80001-2-9 Edition 1.0 2017-01 |
Application of risk management for it-networks incorporating medical devices - Part 2-9: Application guidance - Guidance for use of security assurance cases to demonstrate confidence in IEC TR 80001-2-2 security capabilities |
| 07/06/2020 |
General I (QS/ RM) |
5-130 |
Complete |
ISO |
7010 Third edition 2019-07 |
Graphical symbols - Safety colours and safety signs - Registered safety signs |
| 06/07/2021 |
General II (ES/ EMC) |
19-40 |
Complete |
IEC |
60086-4 Edition 5.0 2019-04 |
Primary batteries - Part 4: Safety of lithium batteries [Including: Corrigendum 1 (2019) and Corrigendum 2 (2020)] |
| 05/26/2025 |
Dental/ ENT |
4-339 |
Complete |
ANSI ADA |
Standard No. 119-2023 |
Dentistry-Manual Toothbrushes |
| 12/22/2025 |
General Plastic Surgery/ General Hospital |
6-515 |
Complete |
ASTM |
D6499-24 |
Standard Test Method for Immunological Measurement of Antigenic Protein in Hevea Natural Rubber (HNR) and its Products |
| 12/20/2021 |
Orthopedic |
11-392 |
Complete |
ASTM |
F2723-21 |
Standard Test Method for Evaluating Mobile Bearing Knee Tibial Baseplate/Bearing Resistance to Dynamic Disassociation |
| 12/19/2022 |
General I (QS/ RM) |
5-139 |
Complete |
ISO |
18250-3 First edition 2018-06 |
Medical devices - Connectors for reservoir delivery systems for healthcare applications - Part 3: Enteral application |
| 05/30/2022 |
General Plastic Surgery/ General Hospital |
6-477 |
Complete |
ISO |
11608-3:2022 |
Needle-based injection systems for medical use - Requirements and test methods - Part 3: Containers and integrated fluid paths |
| 05/30/2022 |
Dental/ ENT |
4-293 |
Complete |
ANSI ADA |
Standard No. 119-2021 |
Manual Toothbrushes |
| 05/26/2025 |
Dental/ ENT |
4-340 |
Complete |
ANSI ADA |
Standard No. 46-2016 |
Dental Patient Chair |
| 05/26/2025 |
Dental/ ENT |
4-341 |
Complete |
ANSI ADA |
Standard No. 47-1-2021 |
Stationary Dental Units and Patient Chairs-Part 1: General Requirements |
| 05/26/2025 |
Dental/ ENT |
4-342 |
Complete |
ANSI ADA |
Standard No. 47-2-2021 |
Stationary Dental Units and Patient Chairs-Part 2: Air, Water, Suction and Wastewater Systems |
| 12/22/2025 |
Orthopedic |
11-432 |
Complete |
ASTM |
F2180-24 |
Standard Specification for Metallic Implantable Strands and Cables |
| 12/22/2025 |
Dental/ ENT |
4-356 |
Complete |
ANSI ADA |
Standard No. 32-2024 |
Dentistry - Orthodontic Wires |
| 12/20/2021 |
General Plastic Surgery/ General Hospital |
6-468 |
Complete |
USP-NF |
M99670_02_01 |
<881> Tensile Strength |
| 12/20/2021 |
General Plastic Surgery/ General Hospital |
6-472 |
Complete |
USP-NF |
M36660_04_01 |
Heparin Lock Flush Solution |
| 12/20/2021 |
Sterility |
14-565 |
Complete |
USP-NF |
M98802_01_01 |
<62> Microbiological Examination of Nonsterile Products: Tests for Specified Microorganisms |
| 12/20/2021 |
Sterility |
14-566 |
Complete |
USP-NF |
M98795_02_01 |
<55> Biological Indicators -- Resistance Performance Tests |
| 12/20/2021 |
Sterility |
14-567 |
Complete |
USP-NF |
M7414_01_01 |
<1229.5> Biological Indicators for Sterilization |
| 12/20/2021 |
Sterility |
14-568 |
Complete |
USP-NF |
M98800_01_01 |
<61> Microbiological Examination of Nonsterile Products: Microbial Enumeration Tests |
| 12/20/2021 |
Sterility |
14-569 |
Complete |
USP-NF |
M98810_01_01 |
<71> Sterility Tests |