Device
tube, feeding
Regulation Description
Gastrointestinal tube and accessories.
Product Code
FPD
Regulation Number
876.5980
Device Class
2
Premarket Reviews
Manufacturer
Decision
VYGON USA
SUBSTANTIALLY EQUIVALENT
1
1. K243361
Nutrifit
MDR Year
MDR Reports
MDR Events
2020
31
31
2021
24
25
2022
19
20
2023
55
59
2024
41
41
2025
10
10
Device Problems
MDRs with this Device Problem
Events in those MDRs
Malposition of Device
31
31
Adverse Event Without Identified Device or Use Problem
28
28
Break
24
27
Material Deformation
17
17
Material Too Rigid or Stiff
16
16
Leak/Splash
9
9
Insufficient Information
9
9
Material Puncture/Hole
8
9
Material Integrity Problem
7
7
Disconnection
6
6
Obstruction of Flow
5
5
Fluid/Blood Leak
4
4
Material Split, Cut or Torn
4
4
Crack
4
4
Device Markings/Labelling Problem
3
3
Detachment of Device or Device Component
3
3
Material Twisted/Bent
3
3
Material Rupture
3
3
Migration or Expulsion of Device
2
2
Physical Resistance/Sticking
2
2
Complete Blockage
2
2
Connection Problem
2
3
Fracture
2
2
Migration
2
2
Difficult to Remove
2
2
Patient Device Interaction Problem
2
3
Air/Gas in Device
2
2
No Flow
1
1
Mechanical Jam
1
1
Loose or Intermittent Connection
1
1
Difficult to Open or Close
1
1
Material Too Soft/Flexible
1
1
Device Dislodged or Dislocated
1
1
Material Separation
1
1
Incorrect Measurement
1
1
Infusion or Flow Problem
1
1
Structural Problem
1
1
Material Perforation
1
1
Inaccurate Flow Rate
1
1
Gas/Air Leak
1
1
Component Missing
1
1
Material Discolored
1
1
Material Fragmentation
1
1
Inadequate Instructions for Healthcare Professional
1
1
Defective Component
1
1
Device Fell
1
1
Difficult to Advance
1
1
Patient-Device Incompatibility
1
1
Restricted Flow rate
1
1
Incomplete or Missing Packaging
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Clinical Signs, Symptoms or Conditions
45
45
Insufficient Information
23
23
Foreign Body In Patient
21
23
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available
13
14
Low Blood Pressure/ Hypotension
11
11
Unspecified Infection
11
11
Bowel Perforation
10
10
No Information
10
10
No Known Impact Or Consequence To Patient
10
10
Bradycardia
9
10
Perforation
9
9
Vomiting
8
8
Perforation of Esophagus
7
7
Vaso-Vagal Response
6
6
Pneumothorax
5
5
Hematuria
5
5
Abscess
4
4
Abdominal Distention
4
4
Hemorrhage/Bleeding
3
3
Hypoxia
3
3
Hyperglycemia
3
3
Skin Discoloration
3
3
Nausea
3
3
Electrolyte Imbalance
2
2
Abnormal Blood Gases
2
2
Apnea
2
2
No Consequences Or Impact To Patient
2
2
Internal Organ Perforation
2
2
Lethargy
2
2
Anemia
1
1
Laceration(s) of Esophagus
1
1
Cardiac Arrest
1
1
Diminished Pulse Pressure
1
1
Pulmonary Emphysema
1
1
Cyst(s)
1
1
Adhesion(s)
1
1
Stomach Ulceration
1
2
Chest Pain
1
1
Increased Intra-Peritoneal Volume (IIPV)
1
1
Necrosis
1
1
Laceration(s)
1
1
Pain
1
1
Choking
1
1
Unspecified Gastrointestinal Problem
1
1
Hypoglycemia
1
1
Gastrointestinal Regurgitation
1
1
Hyponatremia
1
1
Respiratory Distress Syndrome of Newborns
1
1
Pressure Sores
1
1
Ascites
1
1
Recalls
Manufacturer
Recall Class
Date Posted
1
ICU Medical, Inc.
II
Sep-09-2022
2
Kentec Medical, Inc
II
Jul-08-2020
-
-