Device
introducer, syringe needle
Regulation Description
Syringe needle introducer.
Product Code
KZH
Regulation Number
880.6920
Device Class
2
Premarket Reviews
Manufacturer
Decision
EMED TECHNOLOGIES CORPORATION
SUBSTANTIALLY EQUIVALENT
1
SYNTHON HISPANIA S.L.
SUBSTANTIALLY EQUIVALENT
1
MDR Year
MDR Reports
MDR Events
2021
87
91
2022
58
66
2023
35
35
2024
27
27
2025
17
17
2026
1
1
Device Problems
MDRs with this Device Problem
Events in those MDRs
Unintended Ejection
55
55
Misfire
52
52
Defective Device
12
14
Mechanical Jam
9
11
Material Twisted/Bent
7
9
Physical Resistance/Sticking
7
7
Fluid/Blood Leak
5
5
Break
5
6
Therapeutic or Diagnostic Output Failure
5
5
Failure to Deliver
4
4
Ejection Problem
4
4
Patient-Device Incompatibility
3
5
Defective Component
3
3
Insufficient Flow or Under Infusion
3
4
Output Problem
3
3
Activation, Positioning or Separation Problem
2
5
Failure to Infuse
2
2
Adverse Event Without Identified Device or Use Problem
2
2
Packaging Problem
2
2
Device Slipped
2
2
Failure to Eject
2
2
Sharp Edges
2
2
Disconnection
1
1
Complete Blockage
1
1
Loss of or Failure to Bond
1
1
Device Alarm System
1
1
Obstruction of Flow
1
1
Dull, Blunt
1
3
Use of Device Problem
1
1
Unexpected Therapeutic Results
1
1
Material Separation
1
1
Key or Button Unresponsive/not Working
1
1
Noise, Audible
1
1
Insufficient Information
1
1
Unintended Movement
1
1
Protective Measures Problem
1
1
No Flow
1
1
Mechanics Altered
1
1
Improper Flow or Infusion
1
1
Fail-Safe Problem
1
1
Device Dislodged or Dislocated
1
1
Detachment of Device or Device Component
1
1
Connection Problem
1
1
Failure to Fire
1
1
Retraction Problem
1
1
Unintended Collision
1
1
Mechanical Problem
1
1
Leak/Splash
1
1
Difficult to Insert
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Clinical Signs, Symptoms or Conditions
151
154
Insufficient Information
40
45
No Consequences Or Impact To Patient
11
11
Needle Stick/Puncture
6
6
Hyperglycemia
4
4
Bruise/Contusion
3
3
Unspecified Infection
2
2
Hypersensitivity/Allergic reaction
2
4
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available
1
1
Arthralgia
1
1
Sepsis
1
1
Inflammation
1
1
Abrasion
1
1
Fever
1
1
Chest Pain
1
1
Dyspnea
1
1
Pain
1
3
Tinnitus
1
1
Hemorrhage/Bleeding
1
1
Device Embedded In Tissue or Plaque
1
1
-
-