Quick Links: Skip to main page content
Skip to Search
Skip to Topics Menu
Skip to Common Links
U.S. Food & Drug Administration
Follow FDA
En Español
Search FDA
Home
Food
Drugs
Medical Devices
Radiation-Emitting Products
Vaccines, Blood & Biologics
Animal & Veterinary
Cosmetics
Tobacco Products
TPLC - Total Product Life Cycle
FDA Home
medical devices
databases
-
510(k)
|
DeNovo
|
Registration & Listing
|
Adverse Events
|
Recalls
|
PMA
|
HDE
|
Classification
|
Standards
CFR Title 21
|
Radiation-Emitting Products
|
X-Ray Assembler
|
Medsun Reports
|
CLIA
|
TPLC
New Search
show TPLC since
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
Back to Search Results
Device
intrauterine tamponade balloon
Regulation Description
Obstetric-gynecologic specialized manual instrument.
Definition
provides temporary control or reduction of postpartum uterine bleeding
Product Code
OQY
Regulation Number
884.4530
Device Class
2
Premarket Reviews
Manufacturer
Decision
ALYDIA HEALTH
SUBSTANTIALLY EQUIVALENT
2
COOK INCORPORATED
SUBSTANTIALLY EQUIVALENT
1
SINAPI BIOMEDICAL (PTY) , LTD.
SUBSTANTIALLY EQUIVALENT
1
MDR Year
MDR Reports
MDR Events
2020
90
91
2021
113
113
2022
274
274
2023
228
228
2024
215
215
2025
180
180
Device Problems
MDRs with this Device Problem
Events in those MDRs
Adverse Event Without Identified Device or Use Problem
486
486
Fluid/Blood Leak
343
343
Material Rupture
69
69
Inflation Problem
34
34
Detachment of Device or Device Component
21
21
Leak/Splash
20
20
Break
19
19
Material Puncture/Hole
14
14
Improper or Incorrect Procedure or Method
12
12
Material Integrity Problem
12
12
Fracture
11
11
Component Missing
10
10
Suction Failure
9
9
Suction Problem
8
8
Device Dislodged or Dislocated
7
7
Obstruction of Flow
7
7
Infusion or Flow Problem
6
6
Component or Accessory Incompatibility
5
5
Expulsion
5
5
Compatibility Problem
5
5
Component Incompatible
5
5
Loose or Intermittent Connection
4
4
Material Separation
4
4
Decrease in Suction
4
4
Positioning Failure
4
4
Therapeutic or Diagnostic Output Failure
4
4
Defective Device
4
5
Migration or Expulsion of Device
4
4
Mechanical Problem
4
4
Material Split, Cut or Torn
4
4
Deflation Problem
3
3
Use of Device Problem
3
3
Unintended Deflation
3
3
Device Damaged Prior to Use
3
3
Contamination /Decontamination Problem
2
2
Positioning Problem
2
2
Defective Component
2
2
Insufficient Information
2
2
Difficult or Delayed Positioning
2
2
Migration
2
2
Failure to Deflate
2
2
Device Contaminated During Manufacture or Shipping
2
2
Device Slipped
2
2
Difficult to Remove
1
1
Patient Device Interaction Problem
1
1
Difficult to Insert
1
2
Manufacturing, Packaging or Shipping Problem
1
1
Backflow
1
1
Material Twisted/Bent
1
1
Lack of Effect
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Clinical Signs, Symptoms or Conditions
523
523
Hemorrhage/Bleeding
279
279
Insufficient Information
236
236
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available
119
119
No Consequences Or Impact To Patient
62
62
Disseminated Intravascular Coagulation (DIC)
26
26
Uterine Perforation
20
20
Laceration(s)
17
17
No Known Impact Or Consequence To Patient
12
12
Low Blood Pressure/ Hypotension
10
10
Foreign Body In Patient
9
9
Thrombosis/Thrombus
8
8
Blood Loss
8
9
Fever
7
7
Abdominal Pain
4
4
Wound Dehiscence
4
4
Coagulation Disorder
4
4
Rupture
4
4
Cough
3
3
No Information
3
3
Distress
2
2
Bacterial Infection
2
2
Swelling/ Edema
2
2
Perforation of Vessels
2
2
Tachycardia
2
2
Shock
2
2
Abscess
2
2
No Patient Involvement
2
2
Cardiac Arrest
2
2
Obstruction/Occlusion
2
2
Necrosis
2
2
Arthralgia
2
2
Hypovolemic Shock
2
2
Reaction to Medicinal Component of Device
1
1
Pelvic Inflammatory Disease
1
1
Intermenstrual Bleeding
1
1
Implant Pain
1
1
Abdominal Distention
1
1
Perforation
1
1
Exposure to Body Fluids
1
1
Micturition Urgency
1
1
Urinary Retention
1
1
Vomiting
1
1
Muscle Weakness
1
1
Hematoma
1
1
Pain
1
1
Prolapse
1
1
Fluid Discharge
1
1
Genital Bleeding
1
1
No Code Available
1
1
-
-