• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

TPLC - Total Product Life Cycle

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

New Search show TPLC since Back to Search Results
Device catheter, intravascular, diagnostic
Regulation Description Diagnostic intravascular catheter.
Product CodeDQO
Regulation Number 870.1200
Device Class 2


Premarket Reviews
ManufacturerDecision
ABBOTT MEDICAL
  SUBSTANTIALLY EQUIVALENT 1
ACCURATE MEDICAL THERAPEUTICS
  SUBSTANTIALLY EQUIVALENT 1
BIOPTIMAL INTERNATIONAL PTE. , LTD.
  SUBSTANTIALLY EQUIVALENT 1
CORDIS CORPORATION
  SUBSTANTIALLY EQUIVALENT 1
CORDIS US CORP
  SUBSTANTIALLY EQUIVALENT 1
EMBOLX, INC.
  SUBSTANTIALLY EQUIVALENT 1
GENTUITY, LLC
  SUBSTANTIALLY EQUIVALENT 2
IMPERATIVE CARE, INC.
  SUBSTANTIALLY EQUIVALENT 1
MERIT MEDICAL SYSTEMS, INC.
  SUBSTANTIALLY EQUIVALENT 1
PFM MEDICAL, INC.
  SUBSTANTIALLY EQUIVALENT 1
PHENOX, LTD.
  SUBSTANTIALLY EQUIVALENT 2
SPECTRUM VASCULAR
  SUBSTANTIALLY EQUIVALENT 1
TERUMO CLINICAL SUPPLY CO., LTD.
  SUBSTANTIALLY EQUIVALENT 1
TERUMO CORPORATION
  SUBSTANTIALLY EQUIVALENT 1
VASCULAR SOLUTIONS, LLC
  SUBSTANTIALLY EQUIVALENT 1

MDR Year MDR Reports MDR Events
2021 338 340
2022 379 379
2023 391 397
2024 511 511
2025 665 665
2026 364 364

Device Problems MDRs with this Device Problem Events in those MDRs
Material Separation 565 565
Fracture 550 550
Detachment of Device or Device Component 349 349
Difficult to Remove 219 219
Degraded 200 200
Break 175 177
Crack 141 141
Adverse Event Without Identified Device or Use Problem 141 147
Material Split, Cut or Torn 88 88
Difficult to Advance 75 75
Fluid/Blood Leak 72 72
Material Puncture/Hole 52 52
Device Contamination with Chemical or Other Material 52 52
Physical Resistance/Sticking 46 46
Leak/Splash 43 43
Material Deformation 38 38
Deformation Due to Compressive Stress 38 38
Failure to Advance 36 36
Entrapment of Device 36 36
Material Protrusion/Extrusion 32 32
No Display/Image 32 32
Device Contaminated During Manufacture or Shipping 32 32
Communication or Transmission Problem 31 31
Peeled/Delaminated 31 31
Stretched 31 31
Material Fragmentation 31 31
Material Integrity Problem 30 30
Mechanical Problem 28 28
Poor Quality Image 23 23
Material Twisted/Bent 21 21
Incorrect, Inadequate or Imprecise Result or Readings 21 21
Improper or Incorrect Procedure or Method 20 20
Difficult or Delayed Positioning 18 18
Material Frayed 18 18
Tear, Rip or Hole in Device Packaging 17 17
Difficult to Insert 17 17
Device-Device Incompatibility 17 17
Obstruction of Flow 15 15
Unable to Obtain Readings 15 15
Defective Component 15 15
Material Rupture 14 14
Gas/Air Leak 13 13
Contamination 13 13
Disconnection 13 13
Air/Gas in Device 12 12
Use of Device Problem 11 11
Defective Device 10 10
Unraveled Material 10 10
Device Damaged by Another Device 10 10
Difficult to Open or Remove Packaging Material 9 9

Patient Problems MDRs with this Patient Problem Events in those MDRs
No Clinical Signs, Symptoms or Conditions 1996 1997
Foreign Body In Patient 301 301
Insufficient Information 100 101
Vascular Dissection 75 75
Thrombosis/Thrombus 31 31
Obstruction/Occlusion 27 30
Stroke/CVA 22 24
Vasoconstriction 16 16
Device Embedded In Tissue or Plaque 15 15
Hemorrhage/Bleeding 15 15
Cardiac Arrest 14 14
Non specific EKG/ECG Changes 13 13
Low Blood Pressure/ Hypotension 13 13
Perforation of Vessels 13 13
Chest Pain 12 12
Pericardial Effusion 12 12
Air Embolism 11 11
Ischemia Stroke 10 10
Ischemia 10 10
Intracranial Hemorrhage 9 9
Ventricular Fibrillation 9 9
Pain 8 8
Speech Disorder 8 8
Cardiac Tamponade 8 8
Hematoma 6 6
Muscle Weakness 6 6
Dyspnea 6 6
Angina 6 6
Myocardial Infarction 5 5
Embolism/Embolus 5 5
Bradycardia 5 5
Rupture 5 5
Cardiogenic Shock 5 5
Cardiac Perforation 5 5
Thromboembolism 4 5
Infiltration into Tissue 4 4
Paresis 4 5
Failure of Implant 4 4
Hypersensitivity/Allergic reaction 4 4
Paralysis 4 4
Encephalopathy 3 3
No Consequences Or Impact To Patient 3 3
Pseudoaneurysm 3 3
Unspecified Tissue Injury 3 3
Tachycardia 3 3
Laceration(s) 3 3
Brain Injury 3 3
Inflammation 3 4
Arrhythmia 2 2
Foreign Body Embolism 2 2

Recalls
Manufacturer Recall Class Date Posted
1 Abbott Vascular I May-19-2022
2 Angiodynamics, Inc. II Apr-17-2026
3 Angiodynamics, Inc. II Jul-31-2024
4 Boston Scientific Corporation I May-10-2024
5 Cook Incorporated I May-01-2026
6 Cook Incorporated II Apr-06-2026
7 Cook Incorporated I Jun-16-2025
8 Cordis Corporation I Sep-15-2021
9 Cordis US Corp I Nov-09-2023
10 Cordis US Corp II Dec-16-2022
11 Gentuity, LLC II Apr-16-2026
12 Stryker Neurovascular II May-28-2024
13 Stryker Neurovascular II Jul-15-2022
14 Stryker, Inc. II Feb-14-2024
-
-