Device
detector and alarm, arrhythmia
Regulation Description
Arrhythmia detector and alarm (including ST-segment measurement and alarm).
Product Code
DSI
Regulation Number
870.1025
Device Class
2
Premarket Reviews
Manufacturer
Decision
INFOBIONIC, INC.
SUBSTANTIALLY EQUIVALENT
2
IRHYTHM TECHNOLOGIES, INC.
SUBSTANTIALLY EQUIVALENT
1
MEDICALGORITHMICS S.A.
SUBSTANTIALLY EQUIVALENT
1
MEDTRONIC, INC
SUBSTANTIALLY EQUIVALENT
1
MEMTEC CORPORATION
SUBSTANTIALLY EQUIVALENT
1
NATIONAL CARDIAC, INC.
SUBSTANTIALLY EQUIVALENT
1
PREVENTICE TECHNOLOGIES, INC.
SUBSTANTIALLY EQUIVALENT
1
SMARTCARDIA SA
SUBSTANTIALLY EQUIVALENT
1
MDR Year
MDR Reports
MDR Events
2019
3485
3487
2020
3084
3084
2021
3092
3092
2022
1638
1640
2023
1618
1618
2024
1320
1320
2025
650
650
Device Problems
MDRs with this Device Problem
Events in those MDRs
Under-Sensing
3902
3902
Over-Sensing
2751
2751
No Audible Alarm
2529
2529
No Audible Prompt/Feedback
1277
1277
Signal Artifact/Noise
1166
1166
Device Sensing Problem
1118
1118
Communication or Transmission Problem
710
710
Adverse Event Without Identified Device or Use Problem
524
524
Reset Problem
518
518
Migration or Expulsion of Device
415
415
Unable to Obtain Readings
401
401
Electromagnetic Interference
394
394
Failure to Interrogate
281
281
Appropriate Term/Code Not Available
201
201
Device Alarm System
192
194
Defective Alarm
190
190
Battery Problem
179
179
Inaudible or Unclear Audible Prompt/Feedback
163
163
Decreased Sensitivity
157
157
Inappropriate or Unexpected Reset
102
102
Device Displays Incorrect Message
98
98
No Device Output
92
92
Premature Discharge of Battery
88
88
Overheating of Device
79
79
Defective Component
70
70
Data Problem
63
63
Device Difficult to Program or Calibrate
62
62
Failure to Transmit Record
61
61
Output Problem
60
60
Incorrect Measurement
53
53
Defective Device
53
53
Insufficient Information
52
52
Audible Prompt/Feedback Problem
50
50
Patient Device Interaction Problem
48
50
Display or Visual Feedback Problem
47
47
Melted
44
44
Alarm Not Visible
41
41
Therapeutic or Diagnostic Output Failure
37
37
Excessive Heating
34
34
Low Audible Alarm
33
33
Biocompatibility
32
32
Use of Device Problem
31
31
Device-Device Incompatibility
29
29
Patient-Device Incompatibility
27
27
Protective Measures Problem
26
26
Incorrect, Inadequate or Imprecise Result or Readings
26
26
Break
25
25
Temperature Problem
24
24
Smoking
20
20
Delayed Alarm
19
19
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Clinical Signs, Symptoms or Conditions
7904
7904
No Known Impact Or Consequence To Patient
3881
3883
No Consequences Or Impact To Patient
1193
1193
No Patient Involvement
676
676
Unspecified Infection
255
255
Insufficient Information
229
229
Pain
182
182
Erosion
180
180
Skin Inflammation/ Irritation
61
61
Cardiac Arrest
59
59
Unspecified Heart Problem
54
54
Erythema
50
50
Discomfort
46
46
Death
41
41
Hypersensitivity/Allergic reaction
38
38
Impaired Healing
31
31
Blister
26
26
Low Oxygen Saturation
20
20
Rash
19
19
Superficial (First Degree) Burn
18
18
Bradycardia
18
18
Purulent Discharge
18
18
Burning Sensation
17
17
Arrhythmia
17
17
Itching Sensation
17
17
Swelling/ Edema
17
17
Asystole
16
16
Hemorrhage/Bleeding
16
16
Tachycardia
15
15
Hypoxia
15
15
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available
14
14
Skin Irritation
13
13
Burn(s)
12
12
Bruise/Contusion
10
10
Electric Shock
10
10
No Code Available
10
10
Bacterial Infection
10
10
Ventricular Fibrillation
9
9
Chest Pain
8
8
Skin Tears
8
8
Hematoma
7
7
Cardiopulmonary Arrest
7
7
Atrial Fibrillation
7
7
Skin Burning Sensation
7
7
Twiddlers Syndrome
7
7
Loss of consciousness
7
7
Diaphoresis
6
6
Blood Loss
6
6
Localized Skin Lesion
6
6
Wound Dehiscence
6
6
Recalls
Manufacturer
Recall Class
Date Posted
1
GE Healthcare, LLC
II
Dec-20-2019
2
GE Healthcare, LLC
II
Oct-23-2019
3
GE Medical Systems Information Technologies Inc
II
Jun-10-2025
4
Philips North America, LLC
II
Jul-10-2020
5
Philips North America, LLC
II
Jun-01-2019
6
Philips North America
II
Oct-08-2024
7
Philips North America
II
Oct-01-2024
8
Philips North America Llc
II
May-21-2021
9
Philips North America Llc
II
Dec-08-2020
10
Preventice Services, LLC
II
Jul-01-2020
11
Spacelabs Healthcare, Inc.
II
May-03-2023
12
iRhythm Technologies, Inc.
II
Nov-04-2022
-
-