Device
full field digital, system, x-ray, mammographic
Regulation Description
Full-field digital mammography system.
Product Code
MUE
Regulation Number
892.1715
Device Class
2
Premarket Reviews
Manufacturer
Decision
DRTECH CORPORATION
SUBSTANTIALLY EQUIVALENT
1
FUJIFILM CORPORATION
SUBSTANTIALLY EQUIVALENT
1
GE HEALTHCARE
SUBSTANTIALLY EQUIVALENT
3
IMS GIOTTO S.P.A.
SUBSTANTIALLY EQUIVALENT
1
METALTRONICA SPA
SUBSTANTIALLY EQUIVALENT
1
PLANMED OY
SUBSTANTIALLY EQUIVALENT
2
RAYENCE CO., LTD
SUBSTANTIALLY EQUIVALENT
2
SIEMENS MEDICAL SOLUTIONS USA, INC.
SUBSTANTIALLY EQUIVALENT
2
VIEWORKS CO., LTD.
SUBSTANTIALLY EQUIVALENT
1
VMI TECNOLOGIAS LTDA
SUBSTANTIALLY EQUIVALENT
1
MDR Year
MDR Reports
MDR Events
2020
49
49
2021
25
25
2022
36
36
2023
29
29
2024
33
33
2025
6
6
Device Problems
MDRs with this Device Problem
Events in those MDRs
Unintended System Motion
110
110
Break
13
13
Use of Device Problem
7
7
Adverse Event Without Identified Device or Use Problem
6
6
Unintended Movement
5
5
Device Operational Issue
3
3
Insufficient Information
3
3
Fire
2
2
Mechanical Problem
2
2
Positioning Problem
2
2
Device Handling Problem
2
2
No Apparent Adverse Event
2
2
Mechanical Jam
2
2
Unintended Collision
2
2
Output Problem
1
1
Physical Resistance/Sticking
1
1
Device Alarm System
1
1
Crack
1
1
Unintended Electrical Shock
1
1
Material Disintegration
1
1
Material Erosion
1
1
Device Fell
1
1
Defective Device
1
1
Material Integrity Problem
1
1
Therapeutic or Diagnostic Output Failure
1
1
Patient Data Problem
1
1
Incorrect, Inadequate or Imprecise Result or Readings
1
1
Failure to Power Up
1
1
Structural Problem
1
1
Data Problem
1
1
Labelling, Instructions for Use or Training Problem
1
1
Product Quality Problem
1
1
Retraction Problem
1
1
Detachment of Device or Device Component
1
1
Fracture
1
1
Melted
1
1
Display or Visual Feedback Problem
1
1
Improper or Incorrect Procedure or Method
1
1
Device Displays Incorrect Message
1
1
Noise, Audible
1
1
Patient Problems
MDRs with this Patient Problem
Events in those MDRs
No Clinical Signs, Symptoms or Conditions
113
113
No Consequences Or Impact To Patient
35
35
Insufficient Information
8
8
Laceration(s)
4
4
Bone Fracture(s)
3
3
No Known Impact Or Consequence To Patient
3
3
Pain
3
3
Radiation Exposure, Unintended
2
2
Syncope
1
1
Complaint, Ill-Defined
1
1
Electric Shock
1
1
Dizziness
1
1
No Information
1
1
Cardiac Arrest
1
1
Irritation
1
1
Fall
1
1
Muscle/Tendon Damage
1
1
Unspecified Tissue Injury
1
1
Skin Tears
1
1
Bruise/Contusion
1
1
Recalls
Manufacturer
Recall Class
Date Posted
1
GE Medical Systems, SCS
II
Feb-08-2024
2
Hologic, Inc.
II
Feb-18-2020
3
Siemens Medical Solutions USA, Inc
II
Jun-16-2020
-
-