Catalog Number 8065751767 |
Device Problem
Leak/Splash (1354)
|
Patient Problem
No Patient Involvement (2645)
|
Event Date 05/08/2020 |
Event Type
malfunction
|
Manufacturer Narrative
|
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
|
|
Event Description
|
A surgeon reported after finishing preparation work, it was observed that the cassette leak when tested.The product was replaced and the planned procedure was completed.There was no patient involvement and no harm to the operating room staff.
|
|
Manufacturer Narrative
|
Additional information provided in h.6.And h.10.A review of the device history record traceable to the reported lot number indicates that the product was processed and released according to the product¿s acceptance criteria.The customer reported cassette leakage.A sample was not received to date for this complaint report; therefore, visual inspection or functional testing could not be conducted.Without a sample it cannot be determined if there were any physical anomalies that led to the customer's experience.The root cause of the customer's complaint could not be established as a sample has not been received.Without a sample, it is not possible to isolate the root cause.As the root cause is unknown, the relationship, if any, of the device to the reported incident cannot be determined.No action will be taken for this occurrence, as the root cause is unknown and a sample was not returned.The manufacturer internal reference number is: (b)(4).
|
|
Manufacturer Narrative
|
Additional information provided in d.10., h.3., h.6., and h.10.The returned sample was visually inspected and no obvious defects were found.The non-invasive flow sensor (nifs) on the cassette housing was in good condition.A calibrated console representing the current software version was used to test the sample.The ball in the drip chamber¿s check valve moved freely per specification.The light emitting diode (led) rings on the console turned green as the probe connectors were engaged to the console indicating the proper communication between the probe and the console.The submerge leak test was performed on the cassette.No leakage was observed.The sample could prime and pass intraocular pressure (iop) calibration successfully.No anomalies were observed during priming.No system message code was generated during testing.Fluid flowed from the balanced salt solution (bss) bottle to the drain bag without any interfering.No leakage was detected from the pump elastomer or on the pump area of the fluidics module.Cleaning process was able to be performed after functional test had completed.The root cause of the customer's complaint could not be established; the returned sample functioned per specifications.After an investigation of this complaint, it has been determined that this sample functioned per specifications; therefore, no corrective action is required at this time.The manufacturer internal reference number is: (b)(4).
|
|