• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SOFRADIM PRODUCTION SAS MESH SOFRADIM- PARIETEX COMPOSITE MESH MESH, SURGICAL, POLYMERIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SOFRADIM PRODUCTION SAS MESH SOFRADIM- PARIETEX COMPOSITE MESH MESH, SURGICAL, POLYMERIC Back to Search Results
Model Number PCO1510
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Adhesion(s) (1695); Nausea (1970); Cramp(s) (2193); Hernia (2240); Injury (2348); Obstruction/Occlusion (2422); Abdominal Distention (2601)
Event Type  Injury  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
The patient¿s attorney alleged a deficiency against the device. The product was used for therapeutic treatment of a hernia. It was reported that after the implant, the patient experienced small bowel obstruction, adhesions and recurrence. Post-operative patient treatment included small bowel resection and revision surgery.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameMESH SOFRADIM- PARIETEX COMPOSITE MESH
Type of DeviceMESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR 01600
Manufacturer (Section G)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR 01600
Manufacturer Contact
lisa hernandez
60 middletown ave.
north haven, CT 06473
2034925563
MDR Report Key10098358
MDR Text Key193062586
Report Number9615742-2020-01213
Device Sequence Number1
Product Code FTL
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K040998
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation
Type of Report Initial,Followup
Report Date 06/02/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/28/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date03/31/2011
Device Model NumberPCO1510
Device Catalogue NumberPCO1510
Device Lot NumberPGC00272
Was Device Available for Evaluation? No
Is the Reporter a Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received05/13/2020
Was Device Evaluated by Manufacturer? No Answer Provided
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 05/28/2020 Patient Sequence Number: 1
-
-