Model Number TABLETOP
Device Problem Failure to Shut Off (2939)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.(b)(4).
 
Event Description
A healthcare professional reported that the lamp stays on when the illuminator probe is removed.Additional information has been requested.
 
Manufacturer Narrative
The company service representative examined the system and did not indicate replicating the reported event.The illuminator module was replaced.The system was then tested and met all product specifications.The illuminator module was received and tested.The evaluation found a nonconforming fiber cable assembly in the illuminator module.The system was manufactured on march 13, 2009.Based on qa assessment, the product met specifications at the time of release.The root cause of the reported event can be attributed to the nonconforming illuminator module fiber cable assembly.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CONSTELLATION VISION SYSTEM
Type of Device
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
MDR Report Key10212145
MDR Text Key197912065
Report Number2028159-2020-00475
Device Sequence Number1
Product Code HQC
Combination Product (y/n)N
PMA/PMN Number
K101285
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Remedial Action Other
Type of Report Initial,Followup
Report Date 09/08/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/30/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberTABLETOP
Device Catalogue Number8065751150
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/22/2020
Date Manufacturer Received09/01/2020
Is This a Reprocessed and Reused Single-Use Device? No