During a procedure an attempt was made to use one resolute integrity rx coronary drug eluting stent to treat a severely tortuous, severely calcified lesion exhibiting 93% stenosis located in the right coronary artery (rca).Negative prep was performed with no issues noted.The lesion was pre-dilated.Resistance was encountered when advancing the device.It was reported that the catheter/delivery system kinked and deformed.It was stated that the event was due to use of the device in difficult lesion morphology/anatomy, i.E.The event was procedural related and not device related.It was later reported that the device detached 8cm distal to the strain relief.It was stated that this occurred during positioning at the lesion.The device was not kinked and restraightened during use.It was stated that the detached portion removed along with guiding catheter.The patient was reported to be alive with no injuries.
|
Product analysis: kinks were evident on the hypotube.There was a detachment on the hypotube 8.3cm distal to the strain relief.The hypotube material was oval and jagged on both sides of the detachment site.There was no other damage evident to the remainder of the device.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|