PLEXUS MANUFACTURING SDN. BHD CARELINK SMARTSYNC BASE ANALYZER, PACEMAKER GENERATOR FUNCTION Back to Search Results
Model Number 24970A
Device Problems Output Problem (3005); Data Problem (3196)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 06/24/2020
Event Type  Malfunction  
Manufacturer Narrative

If information is provided in the future, a supplemental report will be issued.

 
Event Description

It was reported that there was an issue with signal representation on the programmer when the right ventricle was connected. The analyzer cable was then pulled out of the programmer with the expectation of no signal reading to be displayed but a value was present. Another programmer was used and a signal was clearly visible in the single display. Another attempt was made with the initial programmer but still no signal could be seen in the single display even with the sensitivity adjusted. The physician decided to leave the electrode as the threshold was ok. At the end, the implant measurement value was displayed. There was no issue with the atrial measurement. The programmer remains in use. No patient complications have been reported as a result of this event.

 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameCARELINK SMARTSYNC BASE
Type of DeviceANALYZER, PACEMAKER GENERATOR FUNCTION
Manufacturer (Section D)
PLEXUS MANUFACTURING SDN. BHD
bayan lepas free industrial zo
bayan lepas 11900
MY 11900
Manufacturer (Section G)
PLEXUS MANUFACTURING SDN. BHD
bayan lepas free industrial zo
bayan lepas 11900
MY 11900
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 55112
7635055378
MDR Report Key10300766
MDR Text Key199647193
Report Number3004593495-2020-00758
Device Sequence Number1
Product Code DTC
Combination Product (Y/N)N
Reporter Country CodeGM
PMA/PMN NumberP890003
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type COMPANY REPRESENTATIVE,FOREIG
Reporter Occupation
Type of Report Initial
Report Date 07/21/2020
1 Device Was Involved in the Event
1 Patient Was Involved in the Event
Date FDA Received07/21/2020
Is This An Adverse Event Report? No
Is This A Product Problem Report? Yes
Device Operator HEALTH PROFESSIONAL
Device MODEL Number24970A
Device Catalogue Number24970A
Was Device Available For Evaluation? No
Is The Reporter A Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received06/24/2020
Was Device Evaluated By Manufacturer? No Answer Provided
Is The Device Single Use? No
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse

Patient TREATMENT DATA
Date Received: 07/21/2020 Patient Sequence Number: 1
Treatment
M01A01 TABLET SOFTWARE
-
-