Model Number 97714
Device Problems Failure to Deliver Energy (1211); Failure to Power Up (1476); Connection Problem (2900)
Patient Problems Pain (1994); Therapeutic Effects, Unexpected (2099); Therapeutic Response, Decreased (2271)
Event Date 07/26/2020
Event Type  Malfunction  
Manufacturer Narrative

Other relevant device(s) are: product id: 37751, serial/lot #: (b)(4). If information is provided in the future, a supplemental report will be issued.

 
Event Description

Information was received from a consumer regarding a patient with an implantable neurostimulator (ins) for spinal pain. It was reported the recharger (insr) would not power on. The patient felt their stimulation turn off and they had a return of pain. There was a slight wiggle when the desktop charger (dtc) is plugged into the insr, and resetting the insr did not resolve the issue. A replacement insr was sent to the patient, along with 2 recharger belts that were requested.

 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameSURESCAN
Type of DeviceSTIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF
Manufacturer (Section D)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer (Section G)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer Contact
david gustafson
7000 central avenue ne rcw215
minneapolis, MN 55432
7635149628
MDR Report Key10346349
MDR Text Key201205774
Report Number3004209178-2020-13162
Device Sequence Number1
Product Code LGW
Combination Product (Y/N)N
Reporter Country CodeUS
PMA/PMN NumberP840001
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type CONSUMER
Reporter Occupation
Type of Report Initial,Followup
Report Date 08/19/2020
1 Device Was Involved in the Event
0 PatientS WERE Involved in the Event:
Date FDA Received07/30/2020
Is This An Adverse Event Report? Yes
Is This A Product Problem Report? Yes
Device Operator HEALTH PROFESSIONAL
Device EXPIRATION Date04/28/2018
Device MODEL Number97714
Device Catalogue Number97714
Was Device Available For Evaluation? No
Is The Reporter A Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received08/11/2020
Was Device Evaluated By Manufacturer? Yes
Date Device Manufactured06/07/2017
Is The Device Single Use? Yes
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-