Catalog Number 955367
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Chest Tightness/Pressure (2463)
Event Date 09/04/2020
Event Type  Injury  
Manufacturer Narrative
A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot. The device was not received for evaluation; therefore, a device analysis could not be completed. Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that 15 minutes into treatment with a theranova 400 (ultrafiltration volume set to 2. 6l over 4h of treatment), the patient experienced a ¿stuffy chest¿ sensation. The patient was treated with dexamethasone (dexa) and chlorphenamine (peniramin) intravenously and the theranova 400 was replaced after 2h 20 min of treatment. The patient outcome was not reported. No additional information is available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameTHERANOVA 400
Type of DeviceDIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
Manufacturer (Section G)
BAXTER HEALTHCARE - HECHINGEN BADEN DIALYZER
holger - crafoord - strasse 26
hechingen D-723 79
GM D-72379
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
2242702068
MDR Report Key10602571
MDR Text Key209146626
Report Number9611369-2020-00133
Device Sequence Number1
Product Code KDI
Combination Product (y/n)Y
Reporter Country CodeKS
PMA/PMN Number
NI
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial
Report Date 09/29/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/29/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Catalogue Number955367
Device Lot Number0-6529-H-01
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received09/04/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unkown

Patient Treatment Data
Date Received: 09/29/2020 Patient Sequence Number: 1
-
-