• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SOFRADIM PRODUCTION SAS PROGRIP MESH, SURGICAL, POLYMERIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SOFRADIM PRODUCTION SAS PROGRIP MESH, SURGICAL, POLYMERIC Back to Search Results
Model Number TEM1509G
Device Problems Migration or Expulsion of Device (1395); Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Nerve Damage (1979); Pain (1994); Scarring (2061); Hernia (2240); Injury (2348); No Code Available (3191)
Event Type  Injury  
Manufacturer Narrative

(b)(4). If information is provided in the future, a supplemental report will be issued.

 
Event Description

The patient¿s attorney alleged a deficiency against the device. The product was used for therapeutic treatment of a left inguinal hernia. It was reported that after implant, the patient experienced recurrence and ilioinguinal nerve was entrapped in scar. Post-operative patient treatment included revision surgery, hernia repair with new mesh, partial removal of mesh, and neurectomy.

 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePROGRIP
Type of DeviceMESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR 01600
Manufacturer (Section G)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR 01600
Manufacturer Contact
lisa hernandez
60 middletown ave.
north haven, CT 06473
2034925563
MDR Report Key10670245
MDR Text Key211023636
Report Number9615742-2020-02334
Device Sequence Number1
Product Code FTL
Combination Product (Y/N)N
Reporter Country CodeUS
PMA/PMN NumberK081050
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type CONSUMER
Reporter Occupation
Type of Report Initial,Followup
Report Date 11/06/2020
1 Device Was Involved in the Event
1 Patient Was Involved in the Event
Date FDA Received10/13/2020
Is This An Adverse Event Report? Yes
Is This A Product Problem Report? Yes
Device Operator HEALTH PROFESSIONAL
Device EXPIRATION Date06/30/2020
Device MODEL NumberTEM1509G
Device Catalogue NumberTEM1509G
Device LOT NumberSPG0056X
Was Device Available For Evaluation? No
Is The Reporter A Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received10/21/2020
Was Device Evaluated By Manufacturer? No Answer Provided
Date Device Manufactured08/04/2015
Is The Device Single Use? Yes
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient TREATMENT DATA
Date Received: 10/13/2020 Patient Sequence Number: 1
-
-