C.R. BARD, INC. (BASD) -3006260740 M.R.I. LOW-PROFILE IMPLANTABLE PORT, GROSHONG SINGLE-LUMEN, 7F; PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR Back to Search Results
Catalog Number 0603870C
Device Problems Suction Problem (2170); Detachment of Device or Device Component (2907); Scratched Material (3020); Migration (4003)
Patient Problems Foreign Body In Patient (2687); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Date 09/04/2020
Event Type  Injury  
Manufacturer Narrative
The catalog number identified has not been cleared in the us but is similar to the m.R.I.Low-profile implantable port, groshong single-lumen, 7f products that are cleared in the us.The pro code and 510k number for the m.R.I.Low-profile implantable port, groshong single-lumen, 7f products is identified.As the lot number for the device was provided, a manufacturing review will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.Medical device expiry date - 11/2022.Device not returned.
 
Event Description
It was reported that post port device placement through the right internal jugular vein on the right chest wall, the device was unable to return blood during chemotherapy.Upon inspection it was allegedly found that the latch of the port was detached and had migrated to the pulmonary artery.The detachment was recovered.The current patient status is unknown.
 
Event Description
It was reported that post port device placement through the right internal jugular vein on the right chest wall, the device was found to be unable to return blood during chemotherapy.Upon inspection it was allegedly found that the latch of the port was detached and had migrated to the pulmonary artery.The detachment was recovered.The current patient status is unknown.
 
Manufacturer Narrative
H10: manufacturing review: the device history record review was performed for the reported lot number and this lot meets all release criteria.The manufacturing review did not indicate any possible manufacturing issue that could be related to the reported event.Investigation summary: one mri low profile port and one catheter lock was returned for evaluation.Functional, gross visual, microscopic visual and dimensional evaluations were performed.The investigation is inconclusive for the reported unable to aspirate, detachment and migration issue, as the exact circumstances at the time of the reported event are unknown and the reported event could not be reproduced in the lab.The investigation is confirmed for the identified scratched material issue, as tool damage was noted to the cath-lock.Based on the measurements recorded during sample evaluation and applicable drawings, no measurements recorded could be confirmed to be out of tolerance.Based upon the available information a definitive root cause could not be determined.Labeling review: a review of product labeling documentation (e.G.Procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H10: the catalog number identified in section d4 has not been cleared in the us but is similar to the m.R.I.Low-profile implantable port, groshong single-lumen, 7f products that are cleared in the us.The pro code and 510 k number for the m.R.I.Low-profile implantable port, groshong single-lumen, 7f products are identified in d2 and g5.H10: d4 (expiry date: 11/2022), g3.H11: section a through f ¿ the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
M.R.I. LOW-PROFILE IMPLANTABLE PORT, GROSHONG SINGLE-LUMEN, 7F
Type of Device
PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
MDR Report Key10711360
MDR Text Key212291606
Report Number3006260740-2020-20201
Device Sequence Number1
Product Code LJT
Combination Product (y/n)N
PMA/PMN Number
K924250
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 10/23/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/21/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number0603870C
Device Lot NumberREDZ0872
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/06/2020
Date Manufacturer Received03/31/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age57 YR
Patient Weight60
-
-