Model Number PED-500-16
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Therapeutic Response, Decreased (2271)
Event Date 10/20/2020
Event Type  Injury  
Manufacturer Narrative
Refer to manufacturer report 2029214-2020-01045 for details pertaining to the related reportable event. If information is provided in the future, a supplemental report will be issued.
 
Event Description
Medtronic received a report that the previous pipeline (5x16) still had a small aneurysm after approximately 17 months. The doctor attempted to deploy another pipeline (5x14), but the distal tip would not open after repeated resheathing at the target location. Different techniques or pushing and pulling the wire and microcatheter were applied per training and consult with the pipeline specialist. It was noted the pipeline was not positioned in a bend, more than 50% had been deployed, and resheathing was done more than twice. The pipeline was not deployed, and removed with no issue. Another stent was used and implanted instead to complete the procedure. It was indicated that all devices were prepared as per the instructions for use (ifu), and no patient symptoms or further complications were reported as a result of this event. Post-procedure angiography showed no issues. The patient was undergoing surgery for treatment of a saccular, unruptured aneurysm of the left internal carotid artery. It was noted the patient's vessel tortuosity was normal. Dual antiplatelet therapy (dapt) was administered, and the platelet reactivity units (pru) level was 55. Ancillary devices include a neuron max sheath, navien 058 guidecatheter, phenom 27 microcatheter, synchro standard 014 guidewire.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePIPELINE FLEX
Type of DeviceLASER THERAPY PRODUCT
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
Manufacturer (Section G)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
Manufacturer Contact
tricha miles
9775 toledo way
irvine, CA 92618
7635140379
MDR Report Key10727996
MDR Text Key212778391
Report Number2029214-2020-01046
Device Sequence Number1
Product Code OUT
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P100018.S011
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Type of Report Initial,Followup
Report Date 11/06/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/23/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Expiration Date03/13/2021
Device Model NumberPED-500-16
Device Catalogue NumberPED-500-16
Device Lot NumberA612630
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received10/27/2020
Was Device Evaluated by Manufacturer? No Answer Provided
Date Device Manufactured03/14/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 10/23/2020 Patient Sequence Number: 1
-
-