Model Number PED-425-25
Device Problem Activation Failure (3270)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 10/27/2020
Event Type  malfunction  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
Medtronic received a report that while deploying the pipeline stent, the middle of the device would not open. Resheathing was done twice, but the issue did not resolve. It was noted the stent was positioned in a bend, more than 50% of the pipeline had been deployed, and no additional steps were taken in an attempt to open the stent. The catheter and pipeline were removed together and discarded. Replacement devices were used to complete the procedure. It was indicated that all devices were prepared as per the instructions for use (ifu), and no patient symptoms or further complications were reported as a result of this event. Post-procedure angiography showed good results. The patient was undergoing surgery for treatment of a saccular, unruptured aneurysm of the ophthalmic artery with a max diameter of 19 mm and a 8 mm neck diameter. It was noted the patient's vessel tortuosity was moderate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePIPELINE FLEX
Type of DeviceINTRACRANIAL ANEURYSM FLOW DIVERTER
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
Manufacturer (Section G)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
Manufacturer Contact
tricha miles
9775 toledo way
irvine, CA 92618
7635140379
MDR Report Key10757115
MDR Text Key213912437
Report Number2029214-2020-01072
Device Sequence Number1
Product Code OUT
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P100018.S011
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Type of Report Initial
Report Date 10/29/2020
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received10/29/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date07/08/2021
Device Model NumberPED-425-25
Device Catalogue NumberPED-425-25
Device Lot NumberA672266
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received10/27/2020
Was Device Evaluated by Manufacturer? No Answer Provided
Date Device Manufactured07/09/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-