Catalog Number 1070250-15
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Intimal Dissection (1333)
Event Date 10/03/2020
Event Type  Injury  
Manufacturer Narrative
The device was not returned for evaluation.The reported patient effect of intimal dissection is listed in the xience xpedition, everolimus eluting coronary stent system (eecss), instructions for use (ifu) as a known patient effect of coronary stenting procedures.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Based on the information reviewed, there is no indication of a product quality issue.A conclusive cause for the reported patient effects, and the relationship to the product, if any, cannot be determined.There is no indication of a product quality issue with respect to manufacture, design or labeling of the device.
 
Event Description
It was reported that the procedure was to treat a mildly tortuous, mildly calcified left anterior descending (lad) artery that is 90% stenosed.The lesion was pre-dilated with a 2.0x8mm mini trek balloon and a 2.5x15mm xience xpedition stent was advanced.The stent was deployed at 10 atmospheres (atm).Post dilatation with a 2.5x8mm nc trek balloon at 16 atm performed and an edge dissection was noted at the distal end of the stent.A same size xience xpedition stent was used to treat the dissection.There were no adverse patient sequela and no clinically significant delay.No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE XPEDITION EVEROLIMUS ELUTING CORONARY STENT SYSTEM
Type of Device
DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005718570 (P099)
cashel road
clonmel tipperary
EI  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key10770909
MDR Text Key214130607
Report Number2024168-2020-09102
Device Sequence Number1
Product Code NIQ
Combination Product (y/n)Y
Reporter Country CodeIN
PMA/PMN Number
P110019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 11/02/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/02/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date06/03/2022
Device Catalogue Number1070250-15
Device Lot Number9052841
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received10/08/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
2.5X8MM NC TREK BALLOON
Patient Outcome(s) Required Intervention;
-
-