Model Number 228143 |
Device Problem
Device-Device Incompatibility (2919)
|
Patient Problem
No Consequences Or Impact To Patient (2199)
|
Event Date 10/20/2020 |
Event Type
malfunction
|
Manufacturer Narrative
|
Product complaint # (b)(4).To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Udi: (b)(4).
|
|
Event Description
|
It was reported that during the surgery of meniscus repair, after 1st firing, could not fire again.Another device was used to complete the surgery.There were no adverse consequences to the patient.No additional information could be provided.
|
|
Manufacturer Narrative
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: investigation summary: according to the information provided, it was reported that during the surgery of meniscus repair, after 1st firing, could not fire again.The complaint device was received and evaluated.Visual observations reveal that the needle and implants were not received along with the omnispan gun.In addition, the gun was not presented any physical damages.To test its functionality, a needle was loaded into the device and was tested on a sample rubber strip an both implants were deployed satisfactorily.The complaint cannot be confirmed.We cannot discern a root cause for this failure at this time.A manufacturing record evaluation was performed for the finished device lot number: 6l68082, and no non-conformances were identified.At this point in time, no corrective action is required and no further action is warranted.However, depuy synthes mitek will continue to track any related complaints within this device family as a means of monitoring the extent with which this complaint is observed in the field.
|
|
Manufacturer Narrative
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.D10, h3, h6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|