DEPUY ORTHOPAEDICS INC US PINNACLE MTL INS NEUT36IDX54OD PINNACLE HIP SYSTEM : HIP METAL ACETABULAR LINERS Back to Search Results
Model Number 1218-87-354
Device Problems Naturally Worn (2988); Noise, Audible (3273)
Patient Problems Cyst(s) (1800); Foreign Body Reaction (1868); Inflammation (1932); Pain (1994); Discomfort (2330); Physical Asymmetry (4573); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Date 11/26/2019
Event Type  Injury  
Manufacturer Narrative
(b)(4). Initial reporter occupation: lawyer. If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Pinnacle medical records. After review of medical records patient was revised to addressed pain, discomfort, injury, elevated cobalt and chromium levels, metallosis, a 2 cm x 2 cm cystic lesion filled with gray material on the superior acetabulum and around the stem posterior aspect. Clinic visits reported of bursitis, squeaking, leg length discrepancy and wear debris. Doi: (b)(6) 2008. Dor: (b)(6) 2019; right hip 1st revision.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePINNACLE MTL INS NEUT36IDX54OD
Type of DevicePINNACLE HIP SYSTEM : HIP METAL ACETABULAR LINERS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
Manufacturer (Section G)
DEPUY INT'L LTD. 8010379
st. anthony's rd
leeds LS11 8 DT
UK LS11 8 DT
Manufacturer Contact
kara ditty-bovard
700 orthopaedic dr.
warsaw, IN 46581-0988
6107428552
MDR Report Key10991685
MDR Text Key220921376
Report Number1818910-2020-26791
Device Sequence Number1
Product Code KWA
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K003523
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,other
Reporter Occupation
Type of Report Initial,Followup
Report Date 12/01/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/11/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Device Model Number1218-87-354
Device Catalogue Number121887354
Device Lot Number2730153
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received01/13/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured09/07/2008
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A

Patient Treatment Data
Date Received: 12/11/2020 Patient Sequence Number: 1
Treatment
APEX HOLE ELIM POSITIVE STOP; ARTICULEZE M HEAD 36MM +8.5; PINNACLE 100 ACET CUP 54MM; PINNACLE MTL INS NEUT36IDX54OD; SUMMIT POR TAPER SZ6 STD OFF
-
-